320          MESSAGE    An error occurred on the first read; not enough
                      data read.

           CAUSE      Tape read expected 256 bytes and got less than 200
                      bytes.  Possible tape read error or tape position
                      error.  First read from the tape.  Reading labels.

           ACTION     Clean tape drive and retry.  Clean tape drive,
                      remake tape and retry.

---------------------------------------------------------------

321          MESSAGE    An error was received from RENDEZVOUSIO reading
                      the second label from the tape.

           CAUSE      Error returned from RENDEZVOUSIO for read labels.
                      Second read from the tape.  Possible tape read
                      error or tape position error.

           ACTION     Determine cause of error from RENDEZVOUSIO and
                      correct.  Clean tape drive and retry.  Clean tape
                      drive, remake tape and retry.

---------------------------------------------------------------

322          MESSAGE    An error was received from SENDIO reading the
                      second label from the tape.

           CAUSE      Error returned from SENDIO for read labels.  Second
                      read from the tape.

           ACTION     Determine cause of error from SENDIO and correct.

---------------------------------------------------------------

323          MESSAGE    An error occurred on the second read; not enough
                      data read.

           CAUSE      Tape read expected 256 bytes and got less than 200
                      bytes.  Possible tape read error or tape position
                      error.  Second read from the tape.  Reading labels.

           ACTION     Clean tape drive and retry.  Clean tape drive,
                      remake tape and retry.

---------------------------------------------------------------

324          MESSAGE    An error was received from RENDEZVOUSIO reading
                      the LIF directory from the tape.

           CAUSE      Error returned from RENDEZVOUSIO for read labels.
                      Third read from the tape.  Possible tape read error
                      or tape position error.

           ACTION     Determine cause of error from RENDEZVOUSIO and
                      correct.  Clean tape drive and retry.  Clean tape
                      drive, remake tape and retry.

---------------------------------------------------------------

325          MESSAGE    An error was received from SENDIO reading the LIF
                      directory from the tape.

           CAUSE      Error returned from SENDIO for read labels.  Third
                      read from the tape.

           ACTION     Determine cause of error from SENDIO and correct.

---------------------------------------------------------------

326          MESSAGE    An error occurred reading the LIF directory from
                      the tape; not enough data.

           CAUSE      Tape read expected 256 bytes and got less than 200
                      bytes.  Possible tape read error or tape position
                      error.  Third read from the tape.  Reading labels.

           ACTION     Clean tape drive and retry.  Clean tape drive,
                      remake tape and retry.

---------------------------------------------------------------

327          MESSAGE    This is not an MPE/iX boot tape; LIF label bad.

           CAUSE      LIF label check failed.  Not a valid boot tape.

           ACTION     Retry with a valid boot tape.

---------------------------------------------------------------

328          MESSAGE    This is not an MPE/iX boot tape; MPE/iX label
                      bad.

           CAUSE      MPE/iX label check failed.  Not a valid boot tape.

           ACTION     Retry with a valid boot tape.

---------------------------------------------------------------

330          MESSAGE    An error was received from SENDIO writing disk
                      page 1.

           CAUSE      Error from LOAD_POST writing to sector zero and one
                      of LDEV 1.  First write to sector zero and one of
                      LDEV 1.

           ACTION     Determine cause of error from LOAD_POST and
                      correct.

---------------------------------------------------------------

331          MESSAGE    An error was received from CREATE_OBJECT for
                      first tape I/O buffer.

           CAUSE      Error returned from CREATE_OBJECT for tape I/O
                      buffer 1.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

332          MESSAGE    An error was received from CREATE_OBJECT for a
                      second tape I/O buffer.

           CAUSE      Error returned from CREATE_OBJECT for tape I/O
                      buffer 2.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

333          MESSAGE    An error was received from CREATE_OBJECT for the
                      tape LIF directory buffer.

           CAUSE      Error returned from CREATE_OBJECT for tape LIF
                      directory buffer.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

334          MESSAGE    An error was received from CREATE_OBJECT for the
                      disk LIF directory buffer.

           CAUSE      Error returned from CREATE_OBJECT for disk LIF
                      directory buffer.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

335          MESSAGE    An error was received from CREATE_OBJECT for the
                      tape LIF label buffer.

           CAUSE      Error returned from CREATE_OBJECT for tape LIF
                      label buffer.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

336          MESSAGE    An error was received from CREATE_OBJECT for the
                      tape MPE/iX label.

           CAUSE      Error returned from CREATE_OBJECT for tape MPE/iX
                      label buffer.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

337          MESSAGE    An error was received from HPOPEN for creating
                      LIF directory.

           CAUSE      Error from HPOPEN for LIFDIREC file.

           ACTION     Determine cause of error from HPOPEN and correct.

---------------------------------------------------------------

338          MESSAGE    An error was received from FWRITE for the LIF
                      directory.

           CAUSE      Error from FWRITE for LIFDIREC file.

           ACTION     Determine cause of error from FWRITE and correct.

---------------------------------------------------------------

339          MESSAGE    An error was received from FCLOSE, closing the
                      LIF directory.

           CAUSE      Error from FCLOSE for LIFDIREC file.

           ACTION     Determine cause of error from FCLOSE and correct.

---------------------------------------------------------------

340          MESSAGE    An error occurred writing page 1 of the disk.

           CAUSE      Error from LOAD_POST writing sector zero and one of
                      LDEV 1.

           ACTION     Determine cause of error from LOAD_POST and
                      correct.

---------------------------------------------------------------

341          MESSAGE    An error was received from RENDEZVOUSIO reading
                      the disk labels.

           CAUSE      Error returned from RENDEZVOUSIO for read disk page
                      1, sector zero and one.

           ACTION     Determine cause of error from RENDEZVOUSIO and
                      correct.

---------------------------------------------------------------

342          MESSAGE    An error was received from SENDIO reading the
                      disk labels.

           CAUSE      Error returned from SENDIO for read disk page 1,
                      sector zero and one.

           ACTION     Determine cause of error from SENDIO and correct.

---------------------------------------------------------------

343          MESSAGE    This is not an MPE XL disk.  UPDATE failed;
                      INSTALL required.

           CAUSE      Disk LDEV 1 is not a valid MPE/iX system master
                      volume.

           ACTION     Replace with a valid MPE/iX system master and
                      retry.  Volume cannot be updated, INSTALL is
                      required.

---------------------------------------------------------------

345          MESSAGE    System Abort 345

           CAUSE      Internal error.  Invalid spare state.  Debug code
                      not released.

           ACTION     Call your Hewlett-Packard Representative.

---------------------------------------------------------------

346          MESSAGE    A failure was received from CREATE_OBJECT for a
                      semaphore to use to interlock the label.

           CAUSE      Error returned from CREATE_OBJECT for volume label
                      semaphore.

           ACTION     Determine cause of error from CREATE_OBJECT and
                      correct.

---------------------------------------------------------------

347          MESSAGE    A failure was received from
                      CREATE_BAD_SECTOR_TABLE.

           CAUSE      Error returned from CREATE_BAD_SECTOR_TABLE.

           ACTION     Determine cause of error from
                      CREATE_BAD_SECTOR_TABLE and correct.

---------------------------------------------------------------

348          MESSAGE    A failure was received from XM_INITXM.

           CAUSE      Error from STARTGOLDENXID, transaction management
                      routine.

           ACTION     Determine cause of error from STARTGOLDENXID and
                      correct.

---------------------------------------------------------------

349          MESSAGE    A failure was received from XM_INITXM.

           CAUSE      Error from ENDGOLDENXID, transaction management
                      routine.

           ACTION     Determine cause of error from ENDGOLDENXID and
                      correct.

---------------------------------------------------------------



MPE/iX 5.0 Documentation