Table of Contents
  - The bootstrap
 
  - The initial system loader
 
  
    - Stable storage and nonvolatile
        memory layout
 
    - LIF standard
 
    - Bootable utility format
 
    
 
The system bootstrap, initial program load (IPL) and initial system load (ISL)
standard provides a standard interface through which any
Hewlett-Packard Precision Architecture (PA-RISC) computer can
boot any operating system. The standard also provides a common user interface
for booting PA-RISC systems.
    
  | 
 
WARNING! Do not use this information without service center support.
Unauthorized use will void your warranty and may cause data loss.
  |   
    
The following terms are used in this chapter:
  - PDC
 
  Refers to processor-dependent code as defined in the System I/O
      Architectural Control Document (ACD).  
  - IODC
 
  I/O-dependent code is I/O-device-specific code used to test and access
      I/O devices (also defined in the I/O ACD).  
  - BOOTSTRAP
 
  BOOTSTRAP describes the PDC and IODC functionality needed to bring
      code into memory and launch it.  
  - IPL
 
  Initial program load is the first code brought into the system and
      executed from outside the SPU. This code is loaded by the bootstrap
      code.  
  - ISL
 
  Initial system load is a standard code module that is used during the
      startup of any operating system to provide a standard user interface for
      booting. On some systems, this code may be the IPL, while on others, IPL
      may perform some preliminary tasks and then proceed to load the
      ISL.  
 
The bootstrap and initial system load are discussed on the following pages.
    
    
     
    
     
   |