  - 10
 
  
    - MESSAGE
 
    The code segment number is invalid.  
    - CAUSE
 
    The caller passed in a code segment which is invalid for the process
        whose PIN was passed in, or the code segment is unassigned.  
    - ACTION
 
    None.  
    
 
  - 30
 
  
    - MESSAGE
 
    The data segment number is invalid.  
    - CAUSE
 
    The caller passed in an invalid or an unassigned
        data segment number.  
    - ACTION
 
    None.  
    
 
  - 60
 
  
    - MESSAGE
 
    FREEZE returned a bad status.  
    - CAUSE
 
    The memory manager failed to freeze a compatibility
        mode code or data segment into memory.  
    - ACTION
 
    Examine the process error stack to determine what
        may have caused the problem.  
    
 
  - 65
 
  
    - MESSAGE
 
    UNFREEZE returned a bad status.  
    - CAUSE
 
    The memory manager failed to unfreeze a compatibility mode
        code or data segment into memory.  
    - ACTION
 
    Examine the process error stack to determine what
        may have caused the problem.  
    
 
  - 160
 
  
    - MESSAGE
 
    SWITCH_TO_CM returned a bad status.  
    - CAUSE
 
    Corruption of an operating system data structure
        or operating system code caused SWITCH_TO_CM to fail.  
    - ACTION
 
    Examine the process error stack to determine what
        may have caused the problem.  
    
 
  - 301
 
  
    - MESSAGE
 
    The logical device parameter is not a real device.  
    - CAUSE
 
    An attempt was made to place a non-existent device
        or a spooler virtual device into diagnostic mode.  
    - ACTION
 
    None.  
    
 
  - 302
 
  
    - MESSAGE
 
    The device is currently not in diagnostic mode.  
    - CAUSE
 
    An attempt was made to remove a device not owned
        by the diagnostic system from the diagnostic mode.  
    - ACTION
 
    None.  
    
 
  - 304
 
  
    - MESSAGE
 
    The device is already in diagnostic mode.  
    - CAUSE
 
    An attempt was made to place a device which was already owned by
        the diagnostic system into the diagnostic mode.  
    - ACTION
 
    None.  
    
 
  - 305
 
  
    - MESSAGE
 
    The device is currently in use.  
    - CAUSE
 
    An attempt was made to place a device currently
        being accessed by a user into the diagnostic mode.  
    - ACTION
 
    Try again once the user is no longer accessing the device. The
        SHOWDEV command can be used to determine the current owner.  
    
 
  - 309
 
  
    - MESSAGE
 
    The spooler for the device could not be stopped.  
    - CAUSE
 
    While attempting to place a device into the diagnostic mode,
        the system could not stop the spooler active on the device.  
    - ACTION
 
    Use the STOPSPOOL command to stop the spooler. If sucessful,
        attemp the diagnostic again.  
    
 
  - 311
 
  
    - MESSAGE
 
    The spooler for the device could not be restarted.  
    - CAUSE
 
    While removing the device from the diagnostic mode,
        the system could not restart a spooler for the device.  
    - ACTION
 
    If desired, use the STARTSPOOL command on the console to
        start a spooler for the device.  
    
 
  - 312
 
  
    - MESSAGE
 
    The spooler for the device could not be suspended.  
    - CAUSE
 
    While attempting to place a device into diagnostic mode, the system
        could not suspend the currently active spoolfile.  
    - ACTION
 
    Try using the SUSPENDSPOOL command on the console to
        suspend the currently active spoolfile.  
    
 
  - 320
 
  
    - MESSAGE
 
    The logical console cannot be placed in diagnostic
        mode.  
    - CAUSE
 
    An attempt was made to place the logical console
        into diagnostic mode.  
    - ACTION
 
    Move the logical console to another terminal using
        the CONSOLE command.  
    
 
  - 321
 
  
    - MESSAGE
 
    Disks cannot be placed in diagnostic mode.  
    - CAUSE
 
    An attempt was made to place a disk into diagnostic mode.  
    - ACTION
 
    None.  
    
 
  - 2550
 
  
    - MESSAGE
 
    GETSIR returned a bad status to the fast switch
        stub.  
    - CAUSE
 
    Corruption of an operating system data structure
        or operating system code caused GETSIR to fail.  
    - ACTION
 
    Perform a system dump. Reboot the system using START.  
    
 
  - 2551
 
  
    - MESSAGE
 
    RELSIR returned a bad status to the fast switch
        stub.  
    - CAUSE
 
    Corruption of an operating system data structure
        or operating system code caused RELSIR to fail.  
    - ACTION
 
    Perform a system dump. Reboot the system using START.  
    
 
    
    
     
    
    
      
        
  CM Emulator & OCT (Subsystem 188) | 
       | 
      
        
  Debug Low Level Breakpoint Management (Subsystem 165) | 
     
     
     
   |