|
|
NM callable only.
Sets the value of a session-level variable.
Syntax
CA I32 U32V *
HPCIPUTVAR (varname, status [,itemnum, item] [...]);
 |
NOTE: Up to three itemnum/item pairs can be specified.
|
Parameters
- varname
character array (required)
Passes the name of a session-level variable for which the value needs to
be set. This name must begin with either an alphabetic character or the
underscore character and consists of alphanumeric or underscore
characters. The name is delimited by a nonalphanumeric, nonunderscore
character, and must be <= 255 characters long. The name is not
case-sensitive.
 |
NOTE: It is not a good practice to define CI variables
with the same names as JCW's (job control words). Defining CI variables with
the same names as JCW's may cause unpredictable results.
|
- status
32-bit signed integer by reference (required)
Returns the status of the HPCIPUTVAR call. If no errors or
warnings are encountered, status returns 32 bits of zero.
If errors or warnings are encountered, status is
interpreted as two 16-bit fields:
Bits (0:16) comprise status.info. A negative value
indicates an error condition, and a positive value indicates a warning
condition. Refer to the MPE/iX Error Message Manual Volumes 1, 2 and
3 for a description of its value.
Bits (16:16) comprise status.subsys. The value represents
the subsystem that set the status information. The subsystem identifier
for HPCIPUTVAR is 166.
- itemnum
32-bit unsigned integer by value (optional)
Passes an item number indicating the item. Refer to
Table 7-6 "HPCIPUTVAR Itemnum/Item
Values".
- item
type varies by reference (optional)
Passes the variable information specified in itemnum.
Refer to Table 7-6 "HPCIPUTVAR
Itemnum/Item Values".
Table 7-6 HPCIPUTVAR Itemnum/Item Values
Itemnun |
Mnemonic |
Item Description |
0 | | Itemnum/item pair ignored |
1 | I32 | Integer value assigned to specified
variable name (input):
No other pairs are needed and, if specified, will cause an error. Default:
Not considered an integer value. |
2 | CA | String value assigned to specified
variable name (input):
Default: Not a string variables.
Note: Requires itemnum 11. Itemnum 14 may
be used with strings to set the type and value of
varname. |
3 | I32 | The Boolean value to be assigned to
the specified variable name (input).
Nonzero for a true value, zero for a false value.
Default: Not a boolean variable. |
11 | I32V | Actual length of value string
assigned to variable name (input):
Itemnum/item pair 11 must be passed
whenever itemnum 2 is passed. |
14 | I32 | String interpretation
(strings only; may be used only with itemnum=2) (input).
If you specify itemnum=14, the value of its corresponding
item defines the type-representation (and the value) of
varname based upon an interpretation of the
item paired with itenum=2. Refer to
"Itemnum 14".
Default: 0 (zero). |
Itemnum 14
Given the (Pascal) code fragment
...
my_var := 'TESTVAR ';
var_value := 'Hello world';
val_len := 11;
item := 0; { default }
...
HPCIPUTVAR (my_var, status, 2, var_value, 11, val_len, 14, item);
The value of item will set the type (and value) of
my_var based upon an interpretation of
var_value:
Table 7-7 HPCIPUTVAR itemnum 14 with item
values
Value of item | Value of var_value | Type/Value of my_var |
=0 | "TRUE" | Boolean (TRUE) |
| "FALSE" | Boolean (FALSE) |
| "123" | Integer (123) |
| "other chars" | String ("other chars") |
<>0 | "TRUE" | String ("TRUE") |
| "FALSE" | String ("FALSE") |
| "123" | String ("123") |
| "other chars" | String ("other chars") |
Operation Notes
Allows the value of a session-level variable to be set. The
name must be a valid MPE/iX variable name. The variable's value
can be either a 32-bit signed integer, an array of characters, or
a boolean (TRUE/FALSE).
Related Information
- Intrinsics
HPCIGETVAR, HPCIDELETEVAR
- Commands
SETVAR, DELETEVAR, SHOWVAR
- Manuals
Command Interpreter Access and Variables Programmer's Guide
MPE/iX Commands Reference Manual
|