NM and CM callable.
Writes a logical or physical record or portion of a record
from the stack to a file on any device.
Syntax
I16V UDS I16V U16V
FWRITE (filenum, buffer, length, controlcode);
Parameters
- filenum
16-bit signed integer by value (required)
Passes the file number of the file to be written on.
- buffer
user-defined structure (required)
Passes the record to be written.
- length
16-bit signed integer by value (required)
Passes the number of half words or bytes to be written to the record. If
this value is positive, it signifies half words; if negative, bytes. Zero
indicates that no transfer occurs.
If length is less than the recsize
parameter associated with the record, only the first
length (half words or bytes) is written.
If length is larger than the logical record size and
NOBUF (aoption in FOPEN/HPFOPEN) is not
specified, the FWRITE request is refused and CCL (1) is
returned. If NOBUF is specified, length cannot
exceed the physical record size unless the multirecord
aoption is specified also.
If the multirecord aoption in FOPEN/HPFOPEN is
specified, the excess half words or bytes are written to succeeding
physical records and carriage-control is specified, the actual data
transferred is limited to recsize minus one byte.
(ASC) For asynchronous devices, the physical data transfer is
byte-by-byte. If half words are specified, an even number of bytes is
output.
- controlcode
16-bit unsigned integer by value (required)
Passes a carriage-control code, effective if the file is transferred to a
line printer or terminal (including a spooled file whose destination is a
line printer or a terminal). This parameter is effective only for files
opened with carriage-control specified.
The options are:
- Bits
Value/Meaning
- 0
Print the full record transferred, using single spacing. This
results in a maximum of 132 characters per printed line.
- 1
Use the first character of the data written to satisfy space
control and suppress this character on the printed output. This
results in a maximum of 132 characters of data per printed
line.
Use any octal code from Table 6-2
"Carriage Control Directives" to determine space control and print
the full record transferred. This results in a maximum of 132 characters
per printed line.
If the controlcode parameter is not 0 or 1, and
length is 0, only the space control is executed and no
data is transferred.
Determine whether the carriage-control directive takes effect before
printing (prespace movement) or after printing (postspace movement), with
the FCONTROL intrinsic.
For spooled files, use FWRITE instead of FCONTROL to
set the prespace/postspace control and the auto/no auto page eject
control; use control codes %100 through %103 and %400 through %403 for
this. If one of the above controls is specified with
length=0, no physical I/O occurs.
When a file is opened with CCTL, use the carriage-control codes in one of
the following ways:
As the value of the controlcode parameter.
When controlcode=1, as the first byte of the
buffer array.
The default carriage-control code is postspacing with automatic page
eject. This applies to all Hewlett-Packard subsystems except FORTRAN
77/XL and COBOLII/XL (these have prespacing with automatic page
eject).
(KSAM) This parameter must be specified to satisfy internal requirements,
but it is ignored.
Table 6-2 Carriage Control Directives
Octal Code (ASCII) |
Description of Carriage Action |
%2 - %52 (" ") | Single space (with or without automatic page eject) |
%53 ("+") | No space (next printing at column 1), cannot be used
more than once on the Hewlett-Packard 2608A/S without losing data |
%54 (" ") | Single space (with or without automatic page eject) |
%55 ("-") | Triple space (with or without automatic page eject) |
%56 - %57 (" ") | Single space (with or without automatic page eject) |
%60 ("0") | Double space (with or without automatic page eject) |
%61 ("1") | Conditional page eject (form feed) performed by
the software; if the printer is not at top-of-form, a page eject is performed. Ignored if:
- Postspace mode
The current request has a transfer count of 0 and the previous
request was FOPEN, HPFOPEN, FCLOSE, or
FWRITE specifying a carriage-control directive of
%61.
- Prespace mode
The previous request has a transfer count of 0, and the current
request and previous request are any combination of FOPEN,
HPFOPEN, FCLOSE, or FWRITE specifying a
carriage-control directive of %61.
|
%62 | Skip to one line before top of form (valid for
Hewlett-Packard 2608S and 2563A printers only) |
%63 | A conditional page eject form feed is performed by the
printer; not at top-of-form, a page eject is performed (valid for
Hewlett-Packard 2608S and 2563A printers only) |
%62 - %77 (" ") | Single space (with or without automatic page
eject; for terminals and serial printers) |
%104 - %177 (" ") | Single space (with or without automatic page
eject; for terminals and serial printers) |
%2nn | Space nn lines (no
automatic page eject); nn is any octal number from 0 through 77 |
%300 - %313 | Select VFC Channel 1 - 12 (Hewlett-Packard 2613, 2617, 2618, 2619) |
%300 - %317 | Select VFC Channel 1 - 16 (Hewlett-Packard 2608A/S) |
%300 | Skip to top of form (page eject) |
%301 | Skip to bottom of form |
%302 | Single spacing with automatic page eject |
%303 | Skip to next odd line with automatic page eject |
%304 | Skip to next third line with automatic page eject |
%305 | Skip to next 1/2 page |
%306 | Skip to next 1/4 page |
%307 | Skip to next 1/6 page |
%310 | Skip to bottom of form |
%311 | User option (Hewlett-Packard 2613/17/18/19), skip to one
line before bottom of form (Hewlett-Packard 2608A/S) |
%312 | User option (Hewlett-Packard 2613/17/18/19), skip to one
line before top of form (Hewlett-Packard 2608A/S) |
%313 | User option (Hewlett-Packard 2613/17/18/19), skip to top
of form (Hewlett-Packard 2608A) |
%314 | Skip to next seventh line with automatic page eject |
%315 | Skip to next sixth line with automatic page eject |
%316 | Skip to next fifth line with automatic page eject |
%317 | Skip to next fourth line with automatic page eject |
%310 - %317 | (Hewlett-Packard 2607) |
%314 - %317 | (Hewlett-Packard 2613/17/18/19) |
%320 | No space, no return (next printing physically follows this) |
%321-%377 (" ") | Single space (with or without automatic page eject) |
%400 or %100 | Set postspace movement option (prints first, then
spaces). If previous option was prespace movement, the driver outputs a
line with a skip to VFC Channel 3 (automatic page eject in effect) or a one
line advance (equivalent to an octal code of %201 without automatic page
eject) to clear the buffer |
%401 or %101 | Set prespace movement option (spaces first, then prints) |
%402 or %102 | Set single-space option, with automatic page eject (60 lines per page) |
%403 or %103 | Set single-space option, without automatic page eject (66 lines per page) |
 |
NOTE: If octal codes %55 and %60 are selected with automatic
page eject in effect (by default or following an octal code of %102
or %402), the resulting skip is to a location absolute to the page.
A code of %60 is replaced by %303, and a code of %55 is replaced
by %304. Therefore, the resulting skip can be less than two or three
lines, respectively.
If automatic page eject is not in effect, a true double or
triple space results, but the perforation between pages is not automatically
skipped. For the Hewlett-Packard 2608S and 2563A, if auto-eject
and feature mode are in effect, a code of %60 is replaced by two
codes of %302, and a code of %55 is replaced by three codes of %302.
The resulting skip is double or triple space with auto-eject, respectively.
|
Figure 6-2 Carriage-Control Data
Operation Notes
If information is written to a fixed-length record and the NOBUF
aoption in FOPEN/HPFOPEN is not specified, any unused
portion of the record is padded with binary zeros or ASCII blanks.
When the FWRITE intrinsic is executed, the logical record pointer is
set to the record immediately following the record just written, or to the
first logical record in the next block for NOBUF files. If RIO access
is used, the modified record is set to the ACTIVE state.
When an FWRITE call writes a record beyond the current logical
end-of-file indicator, this indicator is advanced. However, this is noted in
the file label only when the file is closed or when an extent is allocated. If
the physical bounds of the file are reached, CCG ( 0) is returned.
If a magnetic tape is unlabeled (as specified in the FOPEN/HPFOPEN
intrinsic, or in the FILE command) and the program attempts to write
over or beyond the physical or simulated end-of-tape (EOT) marker, the
FWRITE intrinsic returns CCL ( 1). The actual data is written
to the tape, and a call to FCHECK reveals an end-of-tape file error.
After the EOT marker is crossed, all writes to the tape transfer the data
successfully but return CCL ( 1) until the tape crosses the EOT marker
again in the reverse direction (rewind or backspace).
If a magnetic tape is labeled (as specified in the FOPEN/HPFOPEN
intrinsic, or in the FILE command), CCL ( 1) is not returned
when the tape passes the EOT marker. Attempts to write to the tape after an EOT
marker cause end-of-volume (EOV) markers to be written. A message is printed
on the system console requesting another volume (reel of tape) be mounted.
For message files and circular files, this intrinsic logically appends the
record to the end of the file. If a circular file is full, the first block is
deleted, the remaining blocks are logically shifted to the file's head, and the
new record is appended to the end of the file. If a message file is full and
there are no readers, the process waits if there is an FCONTROL=45 in
effect or if this is the first FWRITE after an FOPEN/HPFOPEN
call. Otherwise, CCG ( 0) is returned.
Control codes are ignored for byte stream files. Byte stream files can not be
opened with carriage control.
Condition Codes
- CCE (2)
Request granted.
- CCG (0)
Request denied. The physical bounds of the file prevented further
writing.
- CCL (1)
Request denied. An error occurred; length exceeded the
size of the record in nonmultirecord mode, the FSETMODE option
was enabled to signify recovered tape errors, or the end-of-tape marker
was sensed. If the file is being written to a multivolume labeled
magnetic tape set, CCL (1) is not returned when the end-of-tape
marker is sensed. Instead, end-of-volume labels are written, and a
request is issued to mount the next volume.
Related Information
- Manual
Accessing Files Programmer's Guide
|