|  |  | The network management configuration file must be validated before automatic
  cross-validation with SYSGEN takes place.
    
  The DTS validation procedure starts by displaying the following:
    
   -> Validation of DTS/LINK started. <-
    
  Errors are then listed. When the validation procedure is complete, it will
  print the following:
    
  nnn Encountered Errors
    
  -> Validation of DTS/LINK finished. <-
    
  where nnn is the total number of errors found during
  validation.
    
  A numerical list of validation error messages and actions for each follows.
 
  | Path: NMMGRpath — A read error encountered while reading the data
      record (bad file). (DTSERR=3) |  
  | Level: (DTSERR 3)
      
      Cause: Either a hardware problem occurred or the data record is
      too long.
      
      Action: Try to print the network management configuration file.
      Rebuild the file from a copy of the sample file NMSAMP1.PUB.SYS.
      If the problem persists, contact your Hewlett-Packard support
      representative.
 |  
 
 
  | Path: NMMGRpath — A write error encountered while updating the data
      record (bad file). (DTSERR=4) |  | Level: (DTSERR 4)
        
        Cause: Either a hardware problem occurred or the data record
        file is too small.
        
        Action: If the data record file has been compressed, it is
        impossible to validate the file. Go to the UTILITY screen and
        use the compression utility to make the file larger. Try to validate the
        file. If it still fails, build the file from a copy of the sample file
        NMSAMP1.PUB.SYS. If the problem persists when verifying the new
        file, contact your Hewlett-Packard support representative.
 |  
 
 
  | Path: NMMGRpath — The data record is empty (use Update Data function
      key). (DTSERR=5) |  | Level: (DTSERR 5)
        
        Cause: The data record was not created for the NMMGRpath.
        
        Action: Go back to the screen specified by the NMMGRpath
        and update the screen.
 |  
 
 
  | Path: NMMGRpath — The same physical path is being used at
      LINK.linkname. (DTSERR=6) |  
  | Level: (DTSERR 6)
      
      Cause: The physical path specified for this link is being used.
      
      Action: Go back to the screen specified by the NMMGRpath
      or go to the link screen specified by the linkname and modify the
      physical path.
 |  
 
 
  | Path: NMMGRpath — The same station address is being used at
      LINK.linkname. (DTSERR=7) |  
  | Level: (DTSERR 7)
      
      Cause: The IEEE 802.3 station address is already used. Each
      station address must be unique.
      
      Action: Go back to the screen specified by the NMMGRpath
      or go to the screen specified by the linkname and correct the
      station address.
 |  
 
 
  | Path: NMMGRpath — LINK.linkname is not defined. (DTSERR=8) |  
  | Level: (DTSERR 8)
      
      Cause: The linkname specified on the DTS Configuration
      screen is not defined; therefore, the link data record was not created.
      
      Action: Verify the linkname on the Host Configuration
      screen. If the link data record does not exist, update the DTS
      Configuration screen.
 |  
 
 
  | Path: NMMGRpath — DTS.PROFPC.profilename is not defined.
      (DTSERR=9) |  
  | Level: (DTSERR 9)
      
      Cause: The profilename on the screen specified by the
      NMMGRpath is not defined; therefore, the profile data record does
      not exist.
      
      Action: Check that the profile name exists on the DTS Profile
      Selection screen and, if it does, check that the data record for this
      profile was created.
 |  
 
 
  | Path: NMMGRpath — The same station address or node name is being
      used at DTS.DTC.SELECT.DTCname. (DTSERR=10) |  
  | Level: (DTSERR 10)
      
      Cause: The station address or node name used on the screen
      specified by the NMMGRpath is also used on the screen specified by
      the path DTS.DTC.SELECT.DTCname screen.
      
      Action: Go to the screen specified by the NMMGRpath or to
      the screen specified by the DTC name and modify the station address
      or node name.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012. (DTSERR=11) |  
  | Level: (DTSERR 11)
      
      Cause: The logical device (ldev) number is being used on the
      screen specified by the NMMGRpath and on the
      DTS.DTC.SELECT.DTCname.CARD012 screen.
      
      Action: Go to one of the two screens and change the ldev number.
      The ldev number must be unique for each port.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345. (DTSERR=12) |  
  | Level: (DTSERR 12)
      
      Cause: The same logical device (ldev) number is being used on the
      screen specified by the NMMGRpath and on the
      DTS.DTC.SELECT.DTCname.CARD345.
      
      Action: Go to one of the two screens and change the ldev number.
      The ldev number must be unique for each port.
 |  
 
 
  | Path: NMMGRpath — LDEV #nnn is too big (must be <=4679).
      (DTSERR=14) |  
  | Level: (DTSERR 14)
      
      Cause: The logical device (ldev) number is bigger than the
      allowed maximum ldev number.
      
      Action: Go to the screen specified by the NMMGRpath and
      modify the ldev number.
 |  
 
 
  | Path: NMMGRpath — Too many LDEVs are being used (must be <=4649).
      (DTSERR=15) |  
  | Level: (DTSERR 15)
      
      Cause: Too many logical device (ldev) numbers are being used.
      
      Action: Review the screens that use ldevs and delete some ldev
      numbers. The validation procedure allows a total of 4649 ldevs.
 |  
 
 
  | Path: NMMGRpath — Defined LINK.linkname is not being used.
      (DTSWARN=17) |  
  | Level: (DTSWARN 17)
      
      Cause: The defined linkname is not used by DTS or the
      network interface.
      
      Action: This is a warning only. No action is required.
 |  
 
 
  | Path: NMMGRpath — Too many links are being used (max. number allowed
      = 8). (DTSERR=18) |  
  | Level: (DTSERR 18)
      
      Cause: The link specified in the NMMGRpath cannot be
      processed. Too many links are already defined.
      
      Action: Go back to the DTS Configuration screen and delete the
      link specified in the NMMGRpath. Delete all unused links so that
      eight or less links are being used.
 |  
 
 
  | Path: NMMGRpath — Too many paths are being used (max. number allowed
      = 8). (DTSERR=19) |  
  | Level: (DTSERR 19)
      
      Cause: The link specified in the NMMGRpath cannot be
      processed. Too many physical paths are already defined.
      
      Action: Go back to the DTS Configuration screen and delete the
      link specified in the NMMGRpath. Delete all unused links so that
      eight or less links are being used.
 |  
 
 
  | Path: NMMGRpath — Too many DTCs are being used (max. number allowed
      = 120). (DTSERR=20) |  
  | Level: (DTSERR 20)
      
      Cause: The DTC specified in the NMMGRpath cannot be
      processed. Too many DTCs are already configured.
      
      Action: Go back to the DTC Configuration screen and delete the
      DTC specified in the NMMGRpath.
 |  
 
 
  | Path: NMMGRpath — Too many nodes are being used (max. number allowed
      = 129). (DTSERR=21) |  
  | Level: (DTSERR 21)
      
      Cause: The DTC specified in the NMMGRpath cannot be
      processed. Too many nodes are being used.
      
      Action: Go back to the DTC Configuration screen and delete the
      DTC specified in the NMMGRpath.
 |  
 
 
  | Path: NMMGRpath — Too many classes are being used (max. number
      allowed = 1000). (DTSERR=22) |  
  | Level: (DTSERR 22)
      
      Cause: The total number of classes exceeds the maximum allowed
      number.
      
      Action: Delete class names so that no more than 1000 different
      class names are associated with asynchronous devices.
 |  
 
 
  | Path: NMMGRpath — Too many profiles are being used (max. number
      allowed = 1024). (DTSERR=23) |  
  | Level: (DTSERR 23)
      
      Cause: The total number of defined profiles exceeds the maximum
      allowed.
      
      Action: Delete profiles so that no more than 1024 are
      specified.
 |  
 
 
  | No link is defined. (DTSWARN=24) |  
  | Level: (DTSWARN 24)
      
      Cause: A link is not configured.
      
      Action: Without a configured link, the network management
      configuration file is useless. Return to the configuration screens and add
      a link, making sure that all necessary data records are created.
 |  
 
 
  | No DTC is defined. (DTSWARN=25) |  
  | Level: (DTSWARN 25)
      
      Cause: A DTC is not configured.
      
      Action: An action is not required if neither terminals, printers,
      nor both are needed. If terminals and printers are required, return to the
      configuration screens and add a DTC, making sure that all necessary data
      records are created.
 |  
 
 
  | Path: NMMGRpath — LINK.linkname is shared with network interface.
      (DTSWARN=26) |  
  | Level: (DTSWARN 26)
      
      Cause: The same link is shared between the DTS and NS subsystem.
      A separate link must exist for each of the two subsystems.
      
      Action: Decide which of the two subsystems should use the
      existing link and configure an additional link for the remaining
      subsystem.
 |  
 
 
  | Path: NMMGRpath — Modem type not supported. (DTSERR=30) |  
  | Level: (DTSERR 30)
      
      Cause: The modem type specified on the DTS Terminal Profile
      screen is not 0, 1, or 2. A problem occurred while adding the ldev to a
      device class. This could be caused because the class is used by a
      different type of device such as a HPIB printer.
      
      Action: Remove the class name from the profile for the ldev and
      delete and re- add the ldev. Cross-validate the NMCONFIG.PUB.SYS
      file with SYSGEN. Correct any problems found then restart DTS.
 |  
 
 
  | Path: NMMGRpath — Must supply a Physical Path. (DTSERR=32) |  
  | Level: (DTSERR 32)
      
      Cause: A physical path was not specified in the Physical Path of
      LANIC field.
      
      Action: Go to the DTS Configuration screen and enter the
      appropriate physical path.
 |  
 
 
  | Path: NMMGRpath — Duplicate profile class name profilename used.
      (DTSWARN=34) |  
  | Level: (DTSWARN 34)
      
      Cause: The same class name is used in several terminal profiles
      or the same class name is used in several printer profiles.
      
      Action: No action is required. Informational message only.
 |  
 
 
  | Path: NMMGRpath — Class name duplicated between printer and terminal
      profiles. (DTSERR=35) |  
  | Level: (DTSERR 35)
      
      Cause: The same class name is used for both a terminal profile
      and a printer profile.
      
      Action: Remove the duplicate class name from the terminal profile
      or the printer profile.
 |  
 
 
  | Path: NMMGRpath — Profile profilename specified for non-nailed
      terminals is of PRINTER type. (DTSERR=36) |  
  | Level: (DTSERR 36)
      
      Cause: A printer profile is specified where only a terminal
      profile is allowed.
      
      Action: Change the printer profile to be a terminal
      profile.
 |  
 
 
  | Path: NMMGRpath — Profile profilename specified for non-nailed PAD
      terminals is of PRINTER type. (DTSERR=37) |  
  | Level: (DTSERR 37)
      
      Cause: A printer profile is specified where only a terminal
      profile is allowed.
      
      Action: Change the printer profile to be a terminal profile.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD0. (DTSERR=38) |  
  | Level: (DTSERR 38)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD1. (DTSERR=39) |  
  | Level: (DTSERR 39)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD2. (DTSERR=40) |  
  | Level: (DTSERR 40)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD3. (DTSERR=41) |  
  | Level: (DTSERR 41)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD4. (DTSERR=42) |  
  | Level: (DTSERR 42)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD5. (DTSERR=43) |  
  | Level: (DTSERR 43)
      
      Cause: A PAD name is used more than once.
      
      Action: Remove all of the duplicate references to the PAD name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD0. (DTSERR=44) |  
  | Level: (DTSERR 44)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD1. (DTSERR=45) |  
  | Level: (DTSERR 45)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012.PAD2. (DTSERR=46) |  
  | Level: (DTSERR 46)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD3. (DTSERR=47) |  
  | Level: (DTSERR 47)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD4. (DTSERR=48) |  
  | Level: (DTSERR 48)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345.PAD5. (DTSERR=49) |  
  | Level: (DTSERR 49)
      
      Cause: The same logical device (ldev) number is used more than
      once.
      
      Action: Remove the duplicate ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD012. (DTSERR=50) |  
  | Level: (DTSERR 50)
      
      Cause: The logical device (ldev) number is used more than once in
      the CARD012 configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTCPC.SELECT.DTCname.CARD345. (DTSERR=51) |  
  | Level: (DTSERR 51)
      
      Cause: The logical device (ldev) number is used more than once in
      the CARD345 configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same node name is being used at linkname.
      (DTSERR=52) |  
  | Level: (DTSERR 52)
      
      Cause: The same node name is used more than once.
      
      Action: Remove the duplicate reference to the node name.
 |  
 
 
  | Path: NMMGRpath — Blank NODENAME. (DTSERR=53) |  
  | Level: (DTSERR 53)
      
      Cause: A host node name is not specified on the screen specified
      in the path.
      
      Action: Enter a host node name on the screen specified in the
      path.
 |  
 
 
  | Path: NMMGRpath — The profile for LDEV #nnn, profilename, is not
      defined. (DTSERR=54) |  
  | Level: (DTSERR 54)
      
      Cause: An incorrect profile name was used for the logical device
      (ldev).
      
      Action: Verify the profile name for the logical device in the DTS
      Profile Selection screen.
 |  
 
 
  | Path: NMMGRpath — Profile profilename specified for non-nailed PAD
      terminals is of PRINTER or PADPRINT type. (DTSERR=57) |  
  | Level: (DTSERR 57)
      
      Cause: A printer or PAD printer profile is specified where only a
      terminal or pad terminal profile is allowed.
      
      Action: Change the printer profile to be a terminal profile.
 |  
 
 
  | Path: NMMGRpath — The profile for LDEV #nnn, profilename, is of
      PADTERM or PADPRINT type. (DTSERR=58) |  
  | Level: (DTSERR 58)
      
      Cause: A PAD terminal or PAD printer profile is specified where
      only a terminal or printer profile is allowed.
      
      Action: Change the PAD terminal or PAD printer profile to be a
      terminal or printer profile.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD0. (DTSERR=59) |  
  | Level: (DTSERR 59)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD1. (DTSERR=60) |  
  | Level: (DTSERR 60)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD2. (DTSERR=61) |  
  | Level: (DTSERR 61)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD3. (DTSERR=62) |  
  | Level: (DTSERR 62)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD4. (DTSERR=63) |  
  | Level: (DTSERR 63)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — PAD device name for LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD5. (DTSERR=64) |  
  | Level: (DTSERR 64)
      
      Cause: The same PAD device name is used more than once in the
      configuration.
      
      Action: Remove any duplicate references to the PAD device name.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD0. (DTSERR=65) |  
  | Level: (DTSERR 65)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD1. (DTSERR=66) |  
  | Level: (DTSERR 66)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD012.PAD2. (DTSERR=67) |  
  | Level: (DTSERR 67)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD3. (DTSERR=68) |  
  | Level: (DTSERR 68)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD4. (DTSERR=69) |  
  | Level: (DTSERR 69)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — The same LDEV #nnn is being used at
      DTS.DTC.SELECT.DTCname.CARD345.PAD5. (DTSERR=70) |  
  | Level: (DTSERR 70)
      
      Cause: The logical device (ldev) number is used more than once in
      the configuration.
      
      Action: Remove any duplicate references to the ldev number.
 |  
 
 
  | Path: NMMGRpath — Modem behavior DCE high for LDEV #nnn, defined in
      Profile profilename, is not supported on DTC16 and DTC48. (DTSERR=71) |  
  | Level: (DTSERR 71)
      
      Cause: DCE high modem behavior is not supported for devices on a
      DTC 16 or DTC 48. DCE high is being specified for LDEV
      #nnn, which is on a DTC 16 or DTC 48.
      
      Action: Modify the modem behavior to one that is supported for
      the DTC, or make sure you have specified the right DTC type (not a DTC 16
      or DTC 48) for the device with LDEV #nnn.
 |  
 
 
  | Path: NMMGRpath — Hardware handshaking for LDEV #nnn, defined in
      Profile profilename, is not supported on DTC16 and DTC48.
      (DTSERR=72) |  
  | Level: (DTSERR 72)
      
      Cause: Hardware handshaking is not supported for devices on a DTC
          16 or DTC 48. Hardware handshaking is being specified for LDEV
          #nnn, which is on a DTC 16 or DTC 48.
          
          Action: Make sure you have specified the right DTC type (not
          a DTC 16 or DTC 48), or if you are configuring ports on a DTC 16 or
          DTC 48, do not use a profile that specifies hardware handshaking.
 |  
 
 
  | Path: NMMGRpath — Modem behavior is not supported.
      (DTSERR=73) |  
  | Level: (DTSERR 73)
      
      Cause: An invalid modem behavior has been specified. Valid modem
      behavior values are: 0, 1, 2, or 3. The configuration file may be corrupt.
      
      Action: Modify the modem behavior specified on the Terminal
      Profile or Printer Profile screens to a valid value.
 |  
 
 
  | Path: NMMGRpath — Invalid AFCP timer selection. (DTSERR=74) |  
  | Level: (DTSERR 74)
      
      Cause: You have specified an invalid AFCP timer selection.
      
      Action: Go to the Tune DTC — Timer Selection Screen and
      choose a value from 1 to 6 for an AFCP timer selection.
 |  
 
 
  | Path: NMMGRpath — Invalid Management timer selection.
      (DTSERR=75) |  
  | Level: (DTSERR 75)
      
      Cause: You have specified an invalid management timer selection.
      
      Action: Go to the Tune DTC — Timer Selection Screen and
      choose a value of 1 or 2 for a management timer selection.
 |  
 
 
  | Path: NMMGRpath — Baud rate 38400 for LDEV #nnn, defined in Profile
      profilename, is not supported on DTC16 and DTC48. (DTSERR=76) |  
  | Level: (DTSERR 76)
      
      Cause: You have used a profile that specified a baud rate of
      38400 for a device that is connected to a DTC 16 or DTC 48.
      
      Action: Make sure you specified the right DTC type (not a DTC 16
      or DTC 48), or do not use this profile for the port with LDEV
      #nnn.
 |  
 
 
  | Internal error. Failed to get memory. (DTSERR=77) |  
  | Level: (DTSERR 77)
      
      Cause: The operating system was unable to allocate the memory
      needed to store data used during validation.
      
      Action: Build a new file from the sample file
      NMSAMP1.PUB.SYS. Try to validate the file. If the same error
      message appears when verifying the new file, contact your Hewlett-Packard
      support representative.
 |  
 
 
  | Path: NMMGRpath — Back-to-Back, currently configured on LDEV #nnn,
      must use LDEV # -1. (DTSERR=78) |  
  | Level: (DTSERR 78)
      
      Cause: A profile of type HOST has been configured on a
      DTC port and the ldev specified is not -l.
      
      Action: Ports using HOST profiles are for back-to-back
      and must have an ldev of -l. Go to the screen specified in NMMGRpath
      and change the ldev to -l or use a different profile that is not of type
      HOST.
 |  
 
 
  | Path: NMMGRpath — X.25 card is not allowed in slot s.
      (DTSERR=79) |  
  | Level: (DTSERR 79)
      
      Cause: An X.25 card has been configured in a slot that is not
      allowed for the DTC type.
      
      Action: Go to the DTC specified in the NMMGRpath and
      delete the X.25 card from the slot number s.
 |  
 
 
  | Path: NMMGRpath — Too many X.25 cards are configured. Maximum is 3.
      (DTSERR=80) |  
  | Level: (DTSERR 80)
      
      Cause: To many X.25 cards have been configured in the DTC
      specified in NMMGRpath.
      
      Action: Go to the DTC specified in the NMMGRpath and
      delete one or more X.25 cards.
 |  
 
 
  | Path: NMMGRpath — LAN cardtype is not allowed on DTC16 or DTC48.
      (DTSERR=81) |  
  | Level: (DTSERR 81)
      
      Cause: The configuration for the DTC specified in NMMGRpath
      has a cardtype of "L" configured. This is not allowed for DTC16 or DTC48.
      
      Action: Go to the DTC Configuration screen specified in
      NMMGRpath and enter the correct cardtypes.
 |  
 
 
  | Path: NMMGRpath — Too many LAN cards configured. Only one is allowed.
      (DTSERR=82) |  
  | Level: (DTSERR 82)
      
      Cause: The configuration for the DTC specified in NMMGRpath
      has more than one LAN card specified in the cardtypes.
      
      Action: Go to the DTC Configuration screen specified in
      NMMGRpath and change the extra "L" cardtypes to another valid type.
 |  
 
 
  | Path: NMMGRpath — Unknown cardtype specified for card c.
      (DTSERR=83) |  
  | Level: (DTSERR 83)
      
      Cause: The configuration for the DTC specified in NMMGRpath
      has been corrupted.
      
      Action: Delete the DTC specified in NMMGRpath and re-enter
      the data for this DTC.
 |  
 
 
  | Path: NMMGRpath — Cardtype for card c does not match DTC card
      configuration. (DTSERR=84) |  
  | Level: (DTSERR 84)
      
      Cause: The configuration for the DTC specified in NMMGRpath
      has been corrupted.
      
      Action: Delete the DTC specified in NMMGRpath and re-enter
      the data for this DTC.
 |  
 
 
  | Path: NMMGRpath — Cardtype configured on card c not allowed on
      dtctype. (DTSERR=85) |  
  | Level: (DTSERR 85)
      
      Cause: The configuration for the DTC specified in NMMGRpath
      has been corrupted.
      
      Action: Delete the DTC specified in NMMGRpath and re-enter
      the data for this DTC.
 |  
 
 
  | Path: NMMGRpath — Ldev #nnn> is not valid (must be >= -l and
      <=4679). (DTSERR=86) |  
  | Level: (DTSERR 86)
      
      Cause: The logical device (ldev) number is outside the allowed
      range.
      
      Action: Go to the screen specified in NMMGRpath and modify
      the ldev number.
 |  
 
 
  | Path: NMMGRpath — Ldev of -l is not allowed with printer or terminal
      profile. (DTSERR=87) |  
  | Level: (DTSERR 87)
      
      Cause: An ldev number of -l has been specified on a port that has
      a profile configured that is of type terminal or printer.
      
      Action: Go to the screen specified in NMMGRpath and change
      the ldev or specify a profile that is a type HOST.
 |  
 
 
  | Path: NMMGRpath — Profile for ldev #nnn, <profname>, is of
      HOST type. (DTSERR=88) |  
  | Level: (DTSERR 88)
      
      Cause: Profile <profname> is of type HOST and has
      been configured on a DTC port where ldev specified is not -l.
      
      Action: Ports using HOST profiles are for back-to-back
      and must have an ldev of -l. Go to the screen specified in NMMGRpath
      and change the ldev to -l or use a different profile that is not of type
      HOST.
 |  
 
 
  | Path: NMMGRpath — Too few non-nailed ldevs available above TIO start
      ldev. (DTSERR=89) |  
  | Level: (DTSERR 89)
      
      Cause: There are not enough ldevs available above the TIO start
      ldev number to configure the number of ldev specified.
      
      Action: Lower the number of TIO non-nailed ldevs or delete all
      TIO non-nailed ldevs and specify a lower starting ldev number. Then add
      the desired number of ldevs.
 |  
 
 
  | Path: NMMGRpath — Too few non-nailed ldevs available above PAD start
      ldev. (DTSERR=90) |  
  | Level: (DTSERR 90)
      
      Cause: There are not enough ldevs available above the PAD start
      ldev number to configure the number of ldev specified.
      
      Action: Lower the number of PAD non-nailed ldevs or delete all
      PAD non-nailed ldevs and specify a lower starting ldev number. Then add
      the desired number of ldevs.
 |  
 |