To use the NMMGRVER utility to merge your NS 3000/V
configuration file with the NS 3000/iX NMCONFIG
file and convert it for use with release 2.0 or later, proceed as
follows: At the MPE/iX prompt, type: NMMGRVER.PUB.SYS Merge your NS X.25 3000/XL Server NSCONF
file with the existing NS 3000/XL NMCONFIG
file, and convert it for use with NS 3000/iX release 2.0
or later by entering a file name, for example: NSCONF1.PUB.SYS Enter Y to
proceed when prompted. Select type 1 for NSCONF
type file. NMMGRVER will merge the contents of the existing NMCONFIG
file with the NSCONF file you specified. It
will be saved in the NSCONF file you specified.
In this example, NSCONF1.
If you converted more than one NSCONF
file, decide which one will be the network configuration you want
on the NS 3000/iX system. Rename the file to NMCONFIG.PUB.SYS.
To Update X.25 XL System Access Parameters |  |
On the NS 3000/iX host, use NMMGR to change the following
parameters to provide X.25 XL System Access: If migrating from any NS 3000/V
release before release V delta 7, modify the screen at path @NETXPORT.NI.niname.PROTOCOL.X25
to change the inactivity timer from minutes to seconds. On the screen with the path @LINK,
verify that the DTSLINK is defined. On the screen with the path @LINK.DTSLINK,
verify that the physical path is correctly defined. On the screen with the path @LINK,
add the LINK name and Type (X25) of the X25 link. Note:
to migrate to NS 3000/iX release 2.2 or later, repeat this step
and steps 5 through 7 for each DTC/X.25 Network Access card. On the screen with the path @LINK.linkname,
where the LINK name is the one added in the previous step, add the
DTC Node name and card number for the DTC/X.25 Network Access card. On the screen with the path @NETXPORT.NI.niname.LINK,
add the LINK name entered in Step 4. On the screen with the path @NETXPORT.NI.niname.LINK.linkname,
answer yes or no; then, press the Update key.
To Save X.25 XL System Access Parameters on the Host |  |
Make a list of the following X.25 XL System Access Parameters
on the host that must be re-entered on the DTC. Link Name (the X25 link, not
the DTSLINK). X.25 User Facility Set Parameters.
To Add Other Link Types as Needed |  |
For LAN and Point-to-Point link types, run NMMGR and add the
physical paths. See sections of this manual for the correct values
to be entered for the physical path. To Verify DTS Configuration on the Host |  |
If the datacommunications and terminal subsystem (DTS) has
not been configured, configure the DTS parameters on the host according
to the requirements of your network. For more information, refer
to Getting Started with the DTC and Configuring
Systems for Terminals, Printers, and Other Serial Devices
if you are using PC-based network management. Refer to Configuring
and Managing Host-Based X.25 Links if you are using
host-based network management.
|