Incorrect Node Name [ HP Motif/iX System Administrator's Supplement ] MPE/iX 5.0 Documentation
HP Motif/iX System Administrator's Supplement
Incorrect Node Name
Message
UNKNOWN NODE. (SOCKERR 40)
Error: Can't Open display
Possible cause
The display node name as specified on the HP 3000 host in the DISPLAY
variable or on the command line is incorrect. A node with that name does
not exist or is not responding.
Action
Here is a list of things to check:
* Ensure that the workstation associated with that node name is
booted and functioning.
* Verify that the networking on the workstation has been correctly
configured and started.
* Verify that the node name of the workstation is correctly spelled
and specified in the display specification.
To test the networking, run vt3k from the workstation to connect to the
HP 3000. Use the hostname command to check the node name of the
workstation.
MPE/iX 5.0 Documentation