(S/R) (Continued) [ MPE/iX Error Messages Manual Volume II ] MPE/iX 5.5 Documentation
MPE/iX Error Messages Manual Volume II
(S/R) (Continued)
------------------------------------------------------------
695 MESSAGE 'HIGH' AND 'LOW' PARAMETERS OF THE 'COMPRESS'
OPTION CANNOT BE SPECIFIED TOGETHER (S/R 695)
CAUSE HIGH and LOW parameters are not allowed on the same
command line.
ACTION Delete either LOW or HIGH parameter and retype the
command.
-------------------------------------------------------------
696 MESSAGE 'LOW' PARAMETER OF 'COMPRESS' OPTION CANNOT BE
REDUNDANTLY SPECIFIED (S/R 696)
CAUSE The parameter LOW was specified twice.
ACTION Delete one of the LOW parameters and retype the
command.
-------------------------------------------------------------
697 MESSAGE 'HIGH' PARAMETER OF 'COMPRESS' OPTION CANNOT BE
REDUNDANTLY SPECIFIED (S/R 697)
CAUSE The parameter HIGH was specified twice.
ACTION Delete one of the HIGH parameters and retype the
command.
-------------------------------------------------------------
699 MESSAGE COMPRESSION OPTION IS NOT AVAILABLE ON YOUR
VERSION OF STORE (S/R 699)
CAUSE This option is available only if TurboSTORE XL is
installed on you system.
ACTION TurboSTORE XL is not part of the fundamental
operating system but may be purchased separately.
-------------------------------------------------------------
701 MESSAGE 'SPLITVS' OPTION CANNOT BE USED WITH THE
'TRANSPORT' TO MPEv (S/R 701)
CAUSE SPLITVS and TRANSPORT options are not allowed on
the same command line.
ACTION Delete SPLITVS or TRANSPORT option and retype the
command.
-------------------------------------------------------------
702 MESSAGE WARNING: 'SPLITVS' OPTION HAS BEEN REDUNDANTLY
SPECIFIED (S/R 702)
CAUSE The SPLITVS option was entered more than once.
ACTION Information only.
-------------------------------------------------------------
703 MESSAGE EXPECTED '=volumesetname[,volumesetname...]'
AFTER 'SPLITVS' OPTION SYNTAX
'SPLITVS=volumesetname[,volumesetname...]' (S/R
703)
CAUSE The '=' sign was left out after the SPLITVS option.
ACTION Retype the command and include the '=' sign after
the SPLITVS opti on.
-------------------------------------------------------------
704 MESSAGE INVALID VOLUMESET NAME SPECIFIED FOR
'SPLITVS' OPTION. VOLUMESET NAME MUST
START WITH AN ALPHA "A-Z" AND CONTAIN ONLY
ALPHANUMERIC "A-Z, 0-9", "_" AND "." SYNTAX
'SPLITVS=volumesetname[,volumesetname...]' (S/R
704)
CAUSE The volumeset name specified for SPLITVS is
invalid.
ACTION Retype the command and include a valid volumeset
name.
-------------------------------------------------------------
705 MESSAGE VOLUMESET NAME SPECIFIED FOR 'SPLITVS'
OPTION EXCEEDED THE MAXIMUM ALLOWABLE
LENGTH OF 32 CHARACTERS. SYNTAX
'SPLITVS=volumesetname[,volumesetname...]' (S/R
705)
CAUSE The volumeset name specified for SPLITVS option
includes more than 32 characters.
ACTION Retype the command and make sure the volumeset name
includes 32 characters or less.
-------------------------------------------------------------
706 MESSAGE EXPECTED 'volumesetname[,volumesetname...]' AFTER
'SPLITVS=' WHERE volumesetname IS THE NAME OF
A VOLUME SET THAT IS CURRENTLY MOUNTED
IN A SPLIT STATE ON YOUR SYSTEM. SYNTAX
'SPLITVS=volumesetname[,volumesetname...]' (S/R
706)
CAUSE You have not entered a mounted volumesetname for
SPLITVS option.
ACTION Retype the command and include a mounted
volumesetname with your command.
-------------------------------------------------------------
707 MESSAGE STORE/RESTORE DOES NOT ALLOW MORE THAN TWENTY
(20) "volumesetnames" TO BE SPECIFIED FOR THE
'SPLITVS' OPTION (S/R 707)
CAUSE You have included more than 20 volumesetnames on
the same command line.
ACTION Retype the command and make sure not to exceed 20
volumesetnames.
-------------------------------------------------------------
708 MESSAGE "volumesetname" SPECIFIED DOES NOT EXIST (IS NOT
MOUNTED) ON THIS SYSTEM IN SPLIT STATE (S/R 708)
CAUSE The specified volumesetname does not exist in the
system or it is not mounted.
ACTION Retype the command and make sure you typed the
volumesetname correctly and it is mounted.
-------------------------------------------------------------
709 MESSAGE A "volumesetname" IS SPECIFIED FOR ONVS AS WELL
AS SPLITVS OPTION (S/R 709)
CAUSE A volumesetname included for the ONVS option cannot
be specified for the SPLITVS option and vice versa.
ACTION Use different volumesetnames and retype the
command.
-------------------------------------------------------------
710 MESSAGE 'SPLITVS' OPTION CANNOT BE USED WITH THE 'PURGE'
OPTION (S/R 710)
CAUSE SPLITVS and PURGE options are not allowed on the
same command line.
ACTION Delete PURGE option and retype the command.
-------------------------------------------------------------
711 MESSAGE 'SPLITVS' OPTION CANNOT BE USED WITH THE 'PURGE'
OPTION (S/R 711)
CAUSE SPLITVS and PURGE options are not allowed in the
same command line.
ACTION Delete either SPLITVS or PURGE option and retype
the command.
-------------------------------------------------------------
712 MESSAGE 'SPLITVS' OPTION CANNOT BE USED WITH THE 'ONLINE'
OPTION (S/R 712)
CAUSE SPLITVS and ONLINE options are not allowed in the
same command line.
ACTION Delete either SPLITVS or ONLINE option and retype
the command.
-------------------------------------------------------------
713 MESSAGE 'SPLITVS' OPTION CANNOT BE USED WITH THE
'DYNAMIC' OPTION (S/R 713)
CAUSE SPLITVS and DYNAMIC options are not allowed on the
same command line.
ACTION Delete either SPLITVS or DYNAMIC option and retype
the command.
-------------------------------------------------------------
721 MESSAGE 'MOSET' OPTION CANNOT BE USED WITH THE
'TRANSPORT' TO MPEv (S/R 721)
CAUSE MOSET and TRANSPORT options are not allowed on the
same command line.
ACTION CMSTORE and V/E caanot handle MOSET option. Delete
either MOSET or TRANSPORT option and retype the
command.
-------------------------------------------------------------
722 MESSAGE 'MOSET' OPTION HAS BEEN REDUNDANTLY SPECIFIED
(S/R 722)
CAUSE You specified MOSET option twice.
ACTION Delete one of the MOSET options and retype the
command.
-------------------------------------------------------------
723 MESSAGE 'MOSET' OPTION MAY NOT BE SPECIFIED IN
CONJUNCTION WITH A POSITIONAL DEVICE FILE. Ex.
'STORE....;*MO; MOSET=(MO1,MO2)' IS INVALID (S/R
723)
CAUSE The name of the device in the form of *MO should
not be specified when using MOSET option.
ACTION Delete *MO from your command line and retype the
command.
-------------------------------------------------------------
724 MESSAGE EXPECTED '=(device[,,..])[,(device[,...])]'
AFTER 'MOSET' OPTION WHERE device IS A
VALID LDEV NUMBER OR A DEVICE NAME. SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R 724)
CAUSE You did not include a '=' sign after the MOSET
option.
ACTION Retype the command line and include a '=' sign
after the MOSET option.
-------------------------------------------------------------
725 MESSAGE EXPECTED A '(' TO START A MOSET.
Ex. 'MOSET=(MO1,MO2). SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R 725)
CAUSE You did not include a '(' to start a moset after
the MOSET option.
ACTION Retype the command and include a '(' in your
command line.
-------------------------------------------------------------
726 MESSAGE EXPECTED 'device' FILE SPECIFICATION IN
MOSET. Ex. MOSET=(MO1,MO2). SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R 726)
CAUSE Your MOSET includes invalid device names or ldev
numbers.
ACTION Retype the command and include valid device names
or ldev numbers.
-------------------------------------------------------------
727 MESSAGE MAXIMUM NUMBER OF 'device" SPECIFICATION EXCEEDED
FOR A SERIAL MOSET. Ex. MOSET=(MO1,MO2,...MOn)
EXCEEDS THE MAXIMUM OF 8 (S/R 727)
CAUSE You have included more than 8 devices for MOSET
option.
ACTION Retype the command and type valid number of devices
with MOSET option.
-------------------------------------------------------------
728 MESSAGE EXPECTED A ')' TO TERMINATE A
SERIAL THE 'MOSET' OPTION. SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R 728)
CAUSE You have not included a ')' to terminate your moset
list after the MOSET option.
ACTION Retype the command and include a ')' to terminate
your moset list.
-------------------------------------------------------------
729 MESSAGE EXPECTED A NAME AS 'device' FILE SPECIFICATION
IN MOSET. NAME AND NUMERIC DEVICE SPECIFICATIONS
CAN NOT BE SPECIFIED TOGETHER FOR THE MOSET
OPTION (S/R 729)
CAUSE Mixing device names and ldev numbers are not
allowed with MOSET option.
ACTION Either use all device names or ldev numbers with
the MOSET option.
-------------------------------------------------------------
730 MESSAGE EXPECTED A NUMBER AS 'device' FILE SPECIFICATION
IN MOSET. NAME AND NUMERIC DEVICE SPECIFICATIONS
CAN NOT BE SPECIFIED TOGETHER FOR THE MOSET
OPTION (S/R 730)
CAUSE Mixing device name and ldev numbers with MOSET
option is not allowed.
ACTION Either use all device names or ldev numbers with
the MOSET option.
-------------------------------------------------------------
731 MESSAGE 'MOSET' OPTION NOT ALLOWED IN SYSGEN/STORE. (S/R
731)
CAUSE MOSET option is not allowed when STORE command is
called inside SYSGEN.
ACTION Do not use MOSET option with STORE command from
SYSGEN.
-------------------------------------------------------------
735 MESSAGE 'NAME' OPTION HAS BEEN REDUNDANTLY SPECIFIED
(S/R 735)
CAUSE The NAME option was entered twice.
ACTION Delete one of the NAME options and retype the
command.
-------------------------------------------------------------
736 MESSAGE EXPECTED '=fname' AFTER 'NAME' OPTION WHERE fname
IS THE NAME OF THE BACKUP YOU WANT TO USE FOR THIS
OPERATION. SYNTAX 'NAME=fname[.gname[.aname]]' (S/R
736).
CAUSE You have not included an '=' sign after the NAME
option.
ACTION Include an '=' sign after the NAME option and
retype the command.
-------------------------------------------------------------
737 MESSAGE EXPECTED 'fname' TO BE SPECIFIED FOR 'NAME'
OPTION. A fname NAME MUST START WITH AN ALPHA
"A-Z" AND CONTAIN ONLY ALPHANUMERIC "A-Z, 0-9" NOT
EXCEEDING 8 CHARACTERS IN LENGTH. SYNTAX
'NAME=fname[.gname[.aname]]' (S/R 737).
CAUSE You have entered an invalid filename for the NAME
option.
ACTION Retype the command and include a valid filename for
NAME option.
-------------------------------------------------------------
738 MESSAGE EXPECTED '.gname' AFTER 'NAME' OPTION WHERE gname
QUALIFIES NAME OF THE BACKUP YOU WANT TO USE FOR
THIS OPERATION. SYNTAX 'NAME=fname[.gname[.aname]]'
(S/R 738).
CAUSE You have not included a '.' between fname and
gname in your command line.
ACTION Include a '.' between fname and gname and retype
the command.
-------------------------------------------------------------
739 MESSAGE EXPECTED 'gname' TO BE SPECIFIED FOR 'NAME'
OPTION. A gname NAME MUST START WITH AN ALPHA
"A-Z" AND CONTAIN ONLY ALPHANUMERIC "A-Z, 0-9" NOT
EXCEEDING 8 CHARACTERS IN LENGTH. SYNTAX
'NAME=fname[.gname[.aname]]' (S/R 739).
CAUSE You have entered an invalid gname on your command
line.
ACTION Retype the command and include a valid gname.
-------------------------------------------------------------
740 MESSAGE EXPECTED '.aname' AFTER 'NAME' OPTION WHERE aname
QUALIFIES NAME OF THE BACKUP YOU WANT TO USE FOR
THIS OPERATION. SYNTAX 'NAME=fname[.gname[.aname]]'
(S/R 740).
CAUSE You have not included a '.' between gname and
aname on your command line.
ACTION Retype the command and include a '.' between gname
and aname.
-------------------------------------------------------------
741 MESSAGE EXPECTED 'aname' TO BE SPECIFIED FOR 'NAME'
OPTION. A aname NAME MUST START WITH AN ALPHA
"A-Z" AND CONTAIN ONLY ALPHANUMERIC "A-Z, 0-9" NOT
EXCEEDING 8 CHARACTERS IN LENGTH. SYNTAX
'NAME=fname[.gname[.aname]]' (S/R 741).
CAUSE You have entered an invalid account name with your
command line.
ACTION Retype the command and include a valid account
name.
-------------------------------------------------------------
743 MESSAGE MOSET OPTION IS REQUIRED WITH NAME OPTION FOR
(RE)STORE TO MO. (S/R 743)
CAUSE MOSET option is a required parameter when you
include NAME option on your command line.
ACTION Retype the command and include MOSET option.
-------------------------------------------------------------
744 MESSAGE NAME OPTION IS REQUIRED WITH MOSET OPTION FOR
RESTORE FROM MO. (S/R 744)
CAUSE NAME option is a required parameter along with
MOSET option during restore from magneto-optical.
ACTION Retype the command and include NAME option.
-------------------------------------------------------------
745 MESSAGE THE BACKUP FILE ON LDEV ! IS TOO SMALL FOR STORE
TO MO. (S/R 745)
CAUSE The size of a file to be stored is too large for
the magneto-optical media, probably because of
defective optical media.
ACTION Retry with known good media.
-------------------------------------------------------------
746 MESSAGE INVALID FUNCTION ATTEMPTED ON LDEV ! FOR
(RE)STORE TO MO. (S/R 746)
CAUSE An invalid function request was specified for the
magneto-optical device.
ACTION Contact your HP Support Representative.
-------------------------------------------------------------
747 MESSAGE ATTEMPT TO OPEN THE BACKUP FILE NAMED ! ON LDEV !
ENCOUNTERED ERROR (S/R 747)
CAUSE Unable to open the specified backup media due to
internal error.
ACTION Contact your HP Support representative for further
assistance.
-------------------------------------------------------------
748 MESSAGE STORE/RESTORE ENCOUNTERED ERROR WHILE ATTEMPTING
TO GET THE BYTE ADDRESS OF THE BACKUP FILE ON LDEV
! (S/R 748).
CAUSE Internal error occurred while storing to a
magneto-optical device.
ACTION Contact your HP Support representative for further
assistance.
-------------------------------------------------------------
749 MESSAGE THE BACKUP FILE ON LDEV ! CONTAINS MORE THAN 1
EXTENT. STORE CAN NOT HANDLE MULTIPLE EXTENT FILES
FOR BACKUP TO DISC (S/R 749).
CAUSE A magneto-optical file has more than 1 extent.
ACTION Contact your HP Support Representative.
-------------------------------------------------------------
750 MESSAGE STORE WAS UNABLE TO ALLOCATE SPACE FOR 'MOSET'
OPTION BUFFERS AND CONTROL BLOCKS. (S/R 750)
CAUSE Internal error occurred while storing to MOSET.
ACTION Contact your HP Support representative.
-------------------------------------------------------------
753 MESSAGE THE NAME OPTION IS NOT ALLOWED WITH THE TRANSPORT
OPTION (S/R 753)
CAUSE NAME and TRANSPORT options are not allowed on the
same command line.
ACTION TRANSPORT option is not valid with Magneto-optical
devices. Check the syntax and retype your command.
-------------------------------------------------------------
760 MESSAGE WARNING: 'COPYACD' OPTION HAS BEEN REDUNDANTLY
SPECIFIED (S/R 760)
CAUSE The COPYACD option was entered more than once.
ACTION Information only.
-------------------------------------------------------------
761 MESSAGE 'COPYACD' AND 'NOACD' CANNOT BE USED TOGETHER
(S/R 761)
CAUSE COPYACD and NOACD are not allowed on the same
command line.
ACTION Delete either COPYACD or NOACD and retype the
command.
-------------------------------------------------------------
765 MESSAGE WARNING: 'NOACD' OPTION HAS BEEN REDUNDANTLY
SPECIFIED (S/R 765)
CAUSE The NOACD option was entered more than once.
ACTION Information only.
-------------------------------------------------------------
767 MESSAGE WARNING: 'LDEV' OPTION HAS BEEN REDUNDANTLY
SPECIFIED. SYSGEN/STORE INTERFACE ERROR. (S/R 767)
CAUSE The LDEV option was entered more than once.
ACTION Information only.
-------------------------------------------------------------
768 MESSAGE 'LDEV' OPTION CANNOT BE USED WITH THE 'TRANSPORT'
TO MPEv. SYSGEN/STORE INTERFACE ERROR. (S/R 768)
CAUSE LDEV and TRANSPORT options are not allowed on the
same command line.
ACTION TRANSPORT is not a valid option with STORE command
from SYSGEN. Check your syntax and retype the
command.
-------------------------------------------------------------
769 MESSAGE EXPECTED '=ldev' AFTER 'LDEV' OPTION.SYSGEN/STORE
INTERFACE ERROR. (S/R 769)
CAUSE You did not enter a '=' sign after the LDEV option
in your command line.
ACTION Retype the command and include '=' sign after the
LDEV option.
-------------------------------------------------------------
MPE/iX 5.5 Documentation