Ch 44. CM Emulator & OCT [ MPE/iX Error Messages Manual Volume III ] MPE/iX 5.0 Documentation
MPE/iX Error Messages Manual Volume III
Chapter 44 CM Emulator & OCT
(Subsystem 188)
--------------------------------------------------------------
---------------------------------------------------------------
1 MESSAGE The input node is too low. (CMNODES ERROR 1)
CAUSE Bad input parameter.
ACTION No harm done. Function returns false.
---------------------------------------------------------------
2 MESSAGE The input node is too high. (CMNODES ERROR 2)
CAUSE Bad input parameter.
ACTION No harm done. Function returns false.
---------------------------------------------------------------
3 MESSAGE Invalid node return from debug. (CMNODES ERROR 3)
CAUSE Bad input parameter.
ACTION No harm done. Function returns false.
---------------------------------------------------------------
201 MESSAGE The code segment loaded emulated because
translation is bad.
CAUSE Bad translation.
ACTION Retranslate with a good OCT.
---------------------------------------------------------------
202 MESSAGE The code segment loaded emulated because
translation is bad.
CAUSE Bad translation.
ACTION Retranslate with a good OCT.
---------------------------------------------------------------
203 MESSAGE The code segment loaded emulated because OCT is
for another system.
CAUSE The system and OCT versions are not compatible.
ACTION Retranslate with the appropriate OCT version.
---------------------------------------------------------------
204 MESSAGE The code segment loaded emulated because
translation is bad.
CAUSE Bad translation.
ACTION Retranslate with a good OCT.
---------------------------------------------------------------
205 MESSAGE The code segment loaded emulated because
FFILEINFO failed.
CAUSE Unknown.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
501 MESSAGE OCT error occurred.
---------------------------------------------------------------
502 MESSAGE ! is an invalid code segment name.
---------------------------------------------------------------
503 MESSAGE ! is an invalid code segment number.
---------------------------------------------------------------
504 MESSAGE Failed to open file !.
---------------------------------------------------------------
505 MESSAGE ! is an invalid input file.
---------------------------------------------------------------
506 MESSAGE ! is an unknown argument name.
---------------------------------------------------------------
507 MESSAGE Argument ! is specified in an invalid manner.
---------------------------------------------------------------
508 MESSAGE Attempt to read beyond PB.
---------------------------------------------------------------
510 MESSAGE PLABEL ! is out of bounds.
---------------------------------------------------------------
550 MESSAGE OCT internal error occurred.
CAUSE Internal error.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
551 MESSAGE An error occurred executing CI command.
---------------------------------------------------------------
552 MESSAGE Invalid addressing mode.
---------------------------------------------------------------
553 MESSAGE Invalid data type on stack.
---------------------------------------------------------------
554 MESSAGE Double operand missing HOLE-REG.
---------------------------------------------------------------
555 MESSAGE The maximum register usage has been exceeded.
---------------------------------------------------------------
556 MESSAGE An invalid register is specified.
---------------------------------------------------------------
557 MESSAGE Trap entry was not made.
---------------------------------------------------------------
558 MESSAGE Unable to decode CM instruction.
---------------------------------------------------------------
559 MESSAGE A TEMP REG has been clobbered.
---------------------------------------------------------------
560 MESSAGE Trap entry was made but not PUT.
---------------------------------------------------------------
561 MESSAGE An undefined block label is specified.
---------------------------------------------------------------
562 MESSAGE An unknown INST type was encountered.
---------------------------------------------------------------
563 MESSAGE An invalid BRANCH target is specified.
---------------------------------------------------------------
MPE/iX 5.0 Documentation