514 MESSAGE UPS Monitor logic error: Attempted to map an
invalid UPS alarm status condition. (UPSERR 0514)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
515 MESSAGE UPS Monitor logic error: Attempted to map an
invalid UPS status kind. (UPSERR 0515)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
516 MESSAGE UPS Monitor system call error: Error status !
(Subsystem # !, Error # !) received from procedure
Receive_Msg. (UPSERR 0516)
CAUSE This is a software-detected error condition that
indicates an error occurred in a call to the
specified MPE/iX Operating System procedure when
that procedure was called by the UPS Monitor
software.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
517 MESSAGE UPS Monitor system call error: Error status !
(Subsystem # !, Error # !) received from procedure
Sendio. (UPSERR 0517)
CAUSE This is a software-detected error condition that
indicates an error occurred in a call to the
specified MPE/iX Operating System procedure when
that procedure was called by the UPS Monitor
software.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
518 MESSAGE UPS Monitor logic error: Invalid UID in UPS Table
Entry when starting next UPS I/O request. (UPSERR
0518)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
519 MESSAGE UPS Monitor logic error: Invalid UPS Number in
UPS Table Entry when starting next UPS I/O request.
(UPSERR 0519)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
520 MESSAGE UPS Monitor logic error: Attempt to specify "no
I/O request" when starting next UPS I/O request.
(UPSERR 0520)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
521 MESSAGE UPS Monitor logic error: Invalid Read request
count when starting next UPS I/O request. (UPSERR
0521)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative
---------------------------------------------------------------
522 MESSAGE UPS Monitor logic error: Invalid I/O function
specified when starting next UPS I/O request.
(UPSERR 0522)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
523 MESSAGE UPS Monitor logic error: Attempt to start next
UPS I/O request when previous UPS I/O request still
running. (UPSERR 0523)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
524 MESSAGE UPS Monitor logic error: Attempt to start more
UPS I/O requests than there are UPS devices being
monitored. (UPSERR 0524)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
525 MESSAGE UPS Monitor system call error: Error status !
(Subsystem # !, Error # !) received from procedure
Rel_IO_Resources. (UPSERR 0525)
CAUSE This is a software-detected error condition that
indicates an error occurred in a call to the
specified MPE/iX Operating System procedure when
that procedure was called by the UPS Monitor
software.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
526 MESSAGE UPS Monitor logic error: I/O reply message
received, not expected in present UPS operating
state. (UPSERR 0526)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
527 MESSAGE UPS Monitor logic error: I/O reply message
received, but UPS operating state is
undefined/unknown. (UPSERR 0527)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
528 MESSAGE UPS Monitor logic error: UPS operating substate
invalid while processing a "Go Online" I/O
completion. (UPSERR 0528)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
529 MESSAGE UPS Monitor logic error: UPS operating substate
invalid while processing a "Set Terminal Controls"
I/O completion. (UPSERR 0529)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
530 MESSAGE UPS Monitor logic error: UPS number invalid in
UID of I/O Reply message. (UPSERR 0530)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
531 MESSAGE UPS Monitor logic error: Underflow of a UPS's
number of I/O requests outstanding when processing
a UPS I/O completion. (UPSERR 0531)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
532 MESSAGE UPS Monitor logic error: Underflow of global
number of UPS I/O requests outstanding when
processing a UPS I/O completion. (UPSERR 0532)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
533 MESSAGE UPS LDEV ! I/O Operation warning: Warning status
returned by I/O system at completion of a UPS I/O
request. (UPSWRN 0533)
CAUSE This is a software-detected warning condition that
indicates something unusual occurred in an I/O
request made to a UPS by the UPS Monitor.
ACTION If this warning appears only rarely, then no action
is needed. If it appears frequently, then call
your Hewlett-Packard service representative.
---------------------------------------------------------------
534 MESSAGE UPS LDEV ! I/O Operation error: Error status
returned by I/O system at completion of a UPS I/O
request. (UPSERR 0534)
CAUSE This is a software-detected error condition that
indicates an error in the I/O software subsystems
that the UPS Monitor uses to communicate with UPS
devices.
ACTION If this error appears only rarely, then no action
is needed. If it appears frequently, then call
your Hewlett-Packard service representative.
---------------------------------------------------------------
535 MESSAGE UPS LDEV ! I/O Operation error: A status of
"aborted" was returned by I/O system as completion
status of a UPS I/O request. (UPSERR 0535)
CAUSE This is a software-detected error condition that
indicates an error in the I/O software subsystems
that the UPS Monitor uses to communicate with UPS
devices.
ACTION If this error appears only rarely, then no action
is needed. If it appears frequently, then call
your Hewlett-Packard service representative.
---------------------------------------------------------------
536 MESSAGE UPS LDEV ! I/O Operation error: UPS device failed
to complete a Read I/O request in allotted time.
The Read request timed out. (UPSERR 0536)
CAUSE This is a software-detected error condition that
indicates an error in the I/O software subsystems
that the UPS Monitor uses to communicate with UPS
devices. It could indicate a disconnected I/O
cable or a UPS hardware malfunction.
ACTION Check for proper connection of the UPS I/O
interface cable at both ends. See if the UPS is
powered-on. If those checks do not reveal
the source of the problem, then call your
Hewlett-Packard service representative.
---------------------------------------------------------------
538 MESSAGE UPS Monitor logic error: UPS operating substate
invalid while processing a "Monitoring" I/O
completion. (UPSERR 0538)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
539 MESSAGE UPS Monitor logic error: A UPS I/O completion
reply message was received when none was expected,
or the message received was not the one that was
expected. (UPSERR 0539)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
540 MESSAGE UPS Monitor UPS initialization: UPS LDEV ! was
initialized successfully and is now being
monitored. (UPSWRN 0540)
CAUSE During system startup, the specified UPS device was
successfully initialized by the UPS Monitor.
ACTION No action is needed. This is merely an expected
confirmation that the UPS and UPS Monitor software
are operating correctly.
---------------------------------------------------------------
541 MESSAGE UPS Monitor system call error: Error status !
(Subsystem # !, Error # !) received from procedure
Send_Msg. (UPSERR 0541)
CAUSE This is a software-detected error condition that
indicates an error occurred in a call to the
specified MPE/iX Operating System procedure when
that procedure was called by the UPS Monitor
software.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
542 MESSAGE UPS Monitor logic error: A UPS I/O reply message
was received unexpectedly. The operating state of
the UPS Monitor is inappropriate for receiving an
I/O completion reply message. (UPSERR 0542)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
543 MESSAGE UPS Monitor logic error: Processing of a UPS I/O
completion message resulted in an unknown/undefined
"io_result" variable. (UPSERR 0543)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
544 MESSAGE UPS Monitor logic error: An invalid message was
received by the UPS Monitor at its message port.
The message is not recognized as any of the UPS
Monitor's message types. (UPSERR 0544)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
545 MESSAGE UPS Monitor logic error: An event message of
invalid type was received by the UPS Monitor. The
message is recognized as an event message, but the
kind of event is unknown. (UPSERR 0545)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
546 MESSAGE : UPS Monitor logic error: A timer message of
invalid type was received by the UPS Monitor. The
message is recognized as a timer message, but the
kind of timer is unknown. (UPSERR 0546)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
547 MESSAGE UPS Monitor system call error: Error status !
(Subsystem # !, Error # !) received from procedure
Get_Timer. (UPSERR 0547)
CAUSE This is a software-detected error condition that
indicates an error occurred in a call to the
specified MPE/iX Operating System procedure when
that procedure was called by the UPS Monitor
software.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------
548 MESSAGE UPS Monitor logic error: UPS Monitor attempted to
process a timer event message of an invalid type.
(UPSERR 0548)
CAUSE This is a software-detected error condition that
indicates an error in the UPS Monitor software or
in some other system software, or a system memory
error.
ACTION Call your Hewlett-Packard service representative.
---------------------------------------------------------------