514          MESSAGE    UPS Monitor logic error: Attempted to map an
                      invalid UPS alarm status condition.  (UPSERR 0514)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

515          MESSAGE    UPS Monitor logic error: Attempted to map an
                      invalid UPS status kind. (UPSERR 0515)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

516          MESSAGE    UPS Monitor system call error: Error status !
                      (Subsystem # !, Error # !) received from procedure
                      Receive_Msg. (UPSERR 0516)

           CAUSE      This is a software-detected error condition that
                      indicates an error occurred in a call to the
                      specified MPE/iX Operating System procedure when
                      that procedure was called by the UPS Monitor
                      software.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

517          MESSAGE    UPS Monitor system call error: Error status !
                      (Subsystem # !, Error # !) received from procedure
                      Sendio. (UPSERR 0517)

           CAUSE      This is a software-detected error condition that
                      indicates an error occurred in a call to the
                      specified MPE/iX Operating System procedure when
                      that procedure was called by the UPS Monitor
                      software.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

518          MESSAGE    UPS Monitor logic error: Invalid UID in UPS Table
                      Entry when starting next UPS I/O request. (UPSERR
                      0518)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

519          MESSAGE    UPS Monitor logic error: Invalid UPS Number in
                      UPS Table Entry when starting next UPS I/O request.
                      (UPSERR 0519)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

520          MESSAGE    UPS Monitor logic error: Attempt to specify "no
                      I/O request" when starting next UPS I/O request.
                      (UPSERR 0520)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

521          MESSAGE    UPS Monitor logic error: Invalid Read request
                      count when starting next UPS I/O request. (UPSERR
                      0521)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative

---------------------------------------------------------------

522          MESSAGE    UPS Monitor logic error: Invalid I/O function
                      specified when starting next UPS I/O request.
                      (UPSERR 0522)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

523          MESSAGE    UPS Monitor logic error: Attempt to start next
                      UPS I/O request when previous UPS I/O request still
                      running. (UPSERR 0523)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

524          MESSAGE    UPS Monitor logic error: Attempt to start more
                      UPS I/O requests than there are UPS devices being
                      monitored. (UPSERR 0524)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

525          MESSAGE    UPS Monitor system call error: Error status !
                      (Subsystem # !, Error # !) received from procedure
                      Rel_IO_Resources. (UPSERR 0525)

           CAUSE      This is a software-detected error condition that
                      indicates an error occurred in a call to the
                      specified MPE/iX Operating System procedure when
                      that procedure was called by the UPS Monitor
                      software.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

526          MESSAGE    UPS Monitor logic error: I/O reply message
                      received, not expected in present UPS operating
                      state. (UPSERR 0526)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

527          MESSAGE    UPS Monitor logic error: I/O reply message
                      received, but UPS operating state is
                      undefined/unknown. (UPSERR 0527)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

528          MESSAGE    UPS Monitor logic error: UPS operating substate
                      invalid while processing a "Go Online" I/O
                      completion. (UPSERR 0528)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

529          MESSAGE    UPS Monitor logic error: UPS operating substate
                      invalid while processing a "Set Terminal Controls"
                      I/O completion. (UPSERR 0529)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

530          MESSAGE    UPS Monitor logic error: UPS number invalid in
                      UID of I/O Reply message. (UPSERR 0530)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

531          MESSAGE    UPS Monitor logic error: Underflow of a UPS's
                      number of I/O requests outstanding when processing
                      a UPS I/O completion. (UPSERR 0531)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

532          MESSAGE    UPS Monitor logic error: Underflow of global
                      number of UPS I/O requests outstanding when
                      processing a UPS I/O completion. (UPSERR 0532)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

533          MESSAGE    UPS LDEV ! I/O Operation warning: Warning status
                      returned by I/O system at completion of a UPS I/O
                      request. (UPSWRN 0533)

           CAUSE      This is a software-detected warning condition that
                      indicates something unusual occurred in an I/O
                      request made to a UPS by the UPS Monitor.

           ACTION     If this warning appears only rarely, then no action
                      is needed.  If it appears frequently, then call
                      your Hewlett-Packard service representative.

---------------------------------------------------------------

534          MESSAGE    UPS LDEV ! I/O Operation error: Error status
                      returned by I/O system at completion of a UPS I/O
                      request. (UPSERR 0534)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the I/O software subsystems
                      that the UPS Monitor uses to communicate with UPS
                      devices.

           ACTION     If this error appears only rarely, then no action
                      is needed.  If it appears frequently, then call
                      your Hewlett-Packard service representative.

---------------------------------------------------------------

535          MESSAGE    UPS LDEV ! I/O Operation error: A status of
                      "aborted" was returned by I/O system as completion
                      status of a UPS I/O request. (UPSERR 0535)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the I/O software subsystems
                      that the UPS Monitor uses to communicate with UPS
                      devices.

           ACTION     If this error appears only rarely, then no action
                      is needed.  If it appears frequently, then call
                      your Hewlett-Packard service representative.

---------------------------------------------------------------

536          MESSAGE    UPS LDEV ! I/O Operation error: UPS device failed
                      to complete a Read I/O request in allotted time.
                      The Read request timed out. (UPSERR 0536)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the I/O software subsystems
                      that the UPS Monitor uses to communicate with UPS
                      devices.  It could indicate a disconnected I/O
                      cable or a UPS hardware malfunction.

           ACTION     Check for proper connection of the UPS I/O
                      interface cable at both ends.  See if the UPS is
                      powered-on.  If those checks do not reveal
                      the source of the problem, then call your
                      Hewlett-Packard service representative.

---------------------------------------------------------------

538          MESSAGE    UPS Monitor logic error: UPS operating substate
                      invalid while processing a "Monitoring" I/O
                      completion. (UPSERR 0538)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

539          MESSAGE    UPS Monitor logic error: A UPS I/O completion
                      reply message was received when none was expected,
                      or the message received was not the one that was
                      expected. (UPSERR 0539)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

540          MESSAGE    UPS Monitor UPS initialization: UPS LDEV ! was
                      initialized successfully and is now being
                      monitored. (UPSWRN 0540)

           CAUSE      During system startup, the specified UPS device was
                      successfully initialized by the UPS Monitor.

           ACTION     No action is needed.  This is merely an expected
                      confirmation that the UPS and UPS Monitor software
                      are operating correctly.

---------------------------------------------------------------

541          MESSAGE    UPS Monitor system call error: Error status !
                      (Subsystem # !, Error # !) received from procedure
                      Send_Msg. (UPSERR 0541)

           CAUSE      This is a software-detected error condition that
                      indicates an error occurred in a call to the
                      specified MPE/iX Operating System procedure when
                      that procedure was called by the UPS Monitor
                      software.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

542          MESSAGE    UPS Monitor logic error: A UPS I/O reply message
                      was received unexpectedly. The operating state of
                      the UPS Monitor is inappropriate for receiving an
                      I/O completion reply message. (UPSERR 0542)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

543          MESSAGE    UPS Monitor logic error: Processing of a UPS I/O
                      completion message resulted in an unknown/undefined
                      "io_result" variable. (UPSERR 0543)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

544          MESSAGE    UPS Monitor logic error: An invalid message was
                      received by the UPS Monitor at its message port.
                      The message is not recognized as any of the UPS
                      Monitor's message types. (UPSERR 0544)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

545          MESSAGE    UPS Monitor logic error: An event message of
                      invalid type was received by the UPS Monitor. The
                      message is recognized as an event message, but the
                      kind of event is unknown. (UPSERR 0545)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

546          MESSAGE    :  UPS Monitor logic error: A timer message of
                      invalid type was received by the UPS Monitor. The
                      message is recognized as a timer message, but the
                      kind of timer is unknown. (UPSERR 0546)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

547          MESSAGE    UPS Monitor system call error: Error status !
                      (Subsystem # !, Error # !) received from procedure
                      Get_Timer. (UPSERR 0547)

           CAUSE      This is a software-detected error condition that
                      indicates an error occurred in a call to the
                      specified MPE/iX Operating System procedure when
                      that procedure was called by the UPS Monitor
                      software.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------

548          MESSAGE    UPS Monitor logic error: UPS Monitor attempted to
                      process a timer event message of an invalid type.
                      (UPSERR 0548)

           CAUSE      This is a software-detected error condition that
                      indicates an error in the UPS Monitor software or
                      in some other system software, or a system memory
                      error.

           ACTION     Call your Hewlett-Packard service representative.

---------------------------------------------------------------