MPE/iX SNA Product Configuration [ HP SNA Products Remote System Configuration Guide ] MPE/iX 5.0 Documentation
HP SNA Products Remote System Configuration Guide
MPE/iX SNA Product Configuration
This section covers remote system configuration requirements for the
following MPE/iX SNA products:
* SNA/SDLC Link/iX
* SNA/X.25 Link/iX
* SNA/Token Ring Link/iX
* SNA DHCF/iX
* SNA IMF/iX
* SNA NRJE/iX
* LU 6.2 API/iX
* HP SNADS/iX
This section presents the requirements for:
* ACF/NCP and ACF/VTAM for switched and non-switched lines
* NCP Token-Ring Interconnection (NTRI)
* X.25 NCP Packet Switching Interface (NPSI)
* logmode table parameters.
ACF/NCP and ACF/VTAM Requirements
The ACF/VTAM start parameters refer to the table and buffer size
definitions that ACF/VTAM uses to configure the resource requirements for
the network. Because start parameters apply to the entire VTAM domain
and are not specific to the remote node, HP does not make any
suggestions. HP does recommend that the ACF/VTAM system programmer
review the defined values and make any adjustments for additional
requirements put on the system.
The tables in this section contain the parameters that HP allows for its
MPE/iX SNA products. Operands and values that you must specify are
noted. The tables also contain other operands that are allowed. For
operand definitions, refer to the section Parameter Definitions at the
end of this chapter, or to the appropriate NCP or VTAM manual for the
remote system.
WARNING The HP SNA products are emulations of IBM products. Thus, some
parameters will need particular values based on the requirements
of the HP products. Code these as specified or results are
unpredictable. Operands not listed are not allowed in the HP
SNA services definitions and therefore are not supported. Any
time spent solving problems related to incorrect configuration
of the host is billable to the customer on a time and materials
basis.
For MPE/iX SNA products, more than one PU may be defined for an HP 3000.
A maximum of eight PUs can be defined for each HP 3000 with SDLC links.
Multiple PUs can be defined for each HP 3000 SNA Token Ring Link. The
number of PUs defined depends upon the number of SNA Link products
installed.
A maximum of 255 LUs can be configured for each HP 3000 PU. For SNA
NRJE/iX, it is recommended that at least three LUs be defined. SNA IMF
can support a maximum of 64 LUs. The LU 6.2 products can start a maximum
of eight LUs. See the MPE/iX SNA product documentation for more
information on configuration requirements.
Switched Lines.
Tables 1-9 and 1-10 define the parameters necessary to connect MPE/iX SNA
products to a switched line. Any values listed that are not required are
given as examples. See Parameter Descriptions at the end of this chapter
or refer to the appropriate NCP or VTAM manual for the remote system for
more information.
Table 1-9. MPE/iX SNA Products: NCP/VTAM Switched Line
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| LUDRPOOL macro | |
| | |
- - -
| NUMTYPE2=n | Required by all MPE/iX SNA products. |
| | |
- - -
| GROUP macro | |
| | |
- - -
| DIAL=YES | Required by all SNA products. |
| | |
| LNCTL=SDLC | Required by all MPE/iX SNA products. |
| | |
| REPLYTO | |
| | |
| TEXTTO | |
| | |
| TYPE=NCP | Required by all MPE/iX SNA products. |
| | |
- - -
| LINE macro | |
| | |
- - -
| ADDRESS=line addr | Required by all MPE/iX SNA products. |
| | |
| SPEED=rate | Required by all MPE/iX SNA products. |
| | |
| ANSWER=ON | Required by all MPE/iX SNA products. |
| | |
| CALL=IN | Required by all MPE/iX SNA products. |
| | |
| CLOCKNG=EXT | Required by all MPE/iX SNA products. |
| | |
| DATRATE | |
| | |
| DUPLEX | |
| | |
| ETRATIO | |
| | |
| HDXSP | |
| | |
| INTPRI | |
| | |
| LPDATS | |
| | |
| MAXPU=1 | Required by all MPE/iX SNA products. |
| | |
| NRZI=YES | Allowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 |
| | API/iX, and HP SNADS/iX. |
| | |
| PAUSE | |
| | |
| POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. |
| | Invalid for ACF/NCP version 1, release 3, and |
| | later versions. |
| | |
| RETRIES=7 | |
| | |
| RING | |
| | |
| SPDSEL | |
| | |
| TRANSFER | |
| | |
| OWNER | |
| | |
-------------------------------------------------------------------------------
Table 1-10. MPE/iX SNA Products: VTAMLST Switched Major Node
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| VBUILD macro | |
| | |
- - -
| TYPE=SWNET | Required by all MPE/iX SNA products. |
| | |
- - -
| PU macro | |
| | |
- - -
| puname PU | Required by all MPE/iX SNA products. |
| | |
| ADDR=n | Required by all MPE/iX SNA products. |
| | |
| ANS | Required by all MPE/iX SNA products. |
| | |
| IDBLK=023 | Required for SNA IMF/iX, SNA NRJE/iX, LU 6.2 |
| | API/iX, HP SNADS/iX, SNA DHCF/iX. |
| | |
| IDNUM=n | Required by all MPE/iX SNA products. |
| | |
| DISCNT=NO | |
| | |
| ISTATUS | |
| | |
| MAXLU | |
| | |
| PUTYPE=2 | Required by all MPE/iX SNA products. |
| | |
| SRT | |
| | |
| XID=YES | Required for PU type 2.1 (T2.1). |
| | |
-------------------------------------------------------------------------------
Table 1-10. MPE/iX SNA Products: VTAMLST Switched Major Node (cont.)
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| LU macro | |
| | |
- - -
| luname LU | Required by all MPE/iX SNA products. |
| | |
| LOCADDR=n | Required by all MPE/iX SNA products. Set to 0 |
| | for independent LUs. |
| | |
| BATCH=YES | Recommended for SNA NRJE/iX on applicable |
| | versions of ACF/NCP. This parameter is not |
| | supported for ACF/NCP version 5 or later. |
| | |
| DLOGMOD | Do not specify for SNA DHCF/iX. |
| | |
| ISTATUS | |
| | |
| MODETAB=HPMODTAB | Do not specify for SNA DHCF/iX. |
| | |
| PACING=0 | Recommended for SNA IMF/iX. |
| | |
| SSCPFM=FSS | Required for LU 6.2 API/iX, SNA NRJE/iX, HP |
| | SNADS/iX, and SNA DHCF/iX. |
| | |
| SSCPFM=USSSCS | Required for SNA IMF/iX. |
| | |
| VPACING=0 | Recommended for SNA IMF/iX keyboards and |
| | displays. |
| | |
| USSTAB | Must be specified for SNA IMF/iX only. Do not |
| | specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 |
| | products. |
| | |
| LOGAPPL | Can be used with SNA IMF/iX only. Do not |
| | specify for SNA NRJE/iX, or SNA DHCF/iX. |
| | |
-------------------------------------------------------------------------------
Non-Switched Lines.
Table 1-11 defines the parameters necessary to connect MPE/iX SNA
products to a leased (non-switched) line. See Parameter Descriptions at
the end of this chapter or refer to the appropriate NCP or VTAM manual
for the remote system for more information.
Table 1-11. MPE/iX SNA Products: NCP/VTAM Non-Switched Line
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| GROUP macro | |
| | |
- - -
| DIAL=NO | Required by all MPE/iX SNA products. |
| | |
| LNCTL=SDLC | Required by all MPE/iX SNA products. |
| | |
| REPLYTO | |
| | |
| TEXTTO | |
| | |
| TYPE=NCP | Required by all MPE/iX SNA products. |
| | |
- - -
| LINE macro | |
| | |
- - -
| ADDRESS=line addr | Required by all MPE/iX SNA products. |
| | |
| SPEED=rate | Required by all MPE/iX SNA products. |
| | |
| CLOCKNG=EXT | Required by all MPE/iX SNA products. |
| | |
| DATRATE | |
| | |
| DUPLEX | |
| | |
| ETRATIO | |
| | |
| HDXSP | |
| | |
| INTPRI | |
| | |
| LPDATS | |
| | |
| MAXPU | |
| | |
| NRZI=YES | Allowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 |
| | API/iX, and HP SNADS/iX. |
| | |
| PAUSE | |
| | |
| POLLED=YES | Required for ACF/NCP ver. 1, rel. 1 or 2. |
| | Invalid for ACF/NCP ver. 1, rel. 3, and later |
| | versions. |
| | |
| RETRIES | |
| | |
| SERVLIM | |
| | |
| SPDSEL | |
| | |
| TRANSFER | |
| | |
| OWNER | |
| | |
-------------------------------------------------------------------------------
Table 1-11. MPE/iX SNA Products: NCP/VTAM Non-Switched Line (cont.)
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| SERVICE macro | |
| | |
- - -
| ORDER | |
| | |
| MAXLIST | |
| | |
- - -
| PU macro | |
| | |
- - -
| puname PU | Required by all MPE/iX SNA products. |
| | |
| ADDR=n | Required by all MPE/iX SNA products. |
| | |
| ANS | |
| | |
| DISCNT=NO | |
| | |
| IRETRY | |
| | |
| ISTATUS | |
| | |
| MAXDATA=265 or | |
| | |
| MAXDATA=521 | Required by all MPE/iX SNA products. |
| | |
| MAXOUT=7 | |
| | |
| PASSLIM=7 | |
| | |
| PUTYPE=2 | Required by all MPE/iX SNA products. |
| | |
| RETRIES=7 | |
| | |
| SRT | |
| | |
| XID=YES | Required for type 2.1 node. |
| | |
-------------------------------------------------------------------------------
Table 1-11. MPE/iX SNA Products: NCP/VTAM Non-Switched Line (cont.)
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| LU macro | |
| | |
- - -
| luname LU | Required by all MPE/iX SNA products. |
| | |
| LOCADDR=n | Required by all MPE/iX SNA products. Set to 0 |
| | for independent LUs. |
| | |
| BATCH=YES | Recommended for SNA NRJE/iX on applicable |
| | versions of ACF/NCP. This parameter is not |
| | supported for ACF/NCP version 5 or later. |
| | |
| DLOGMOD | Do not specify for SNA DHCF/iX. |
| | |
| ISTATUS | |
| | |
| MODETAB=HPMODTAB | Do not specify for SNA DHCF/iX. |
| | |
| PACING=0 | Recommended for SNA IMF/iX keyboards and |
| | displays. |
| | |
| SSCPFM=FSS | Required for LU 6.2 API/iX, HP SNADS/iX, SNA |
| | NRJE/iX, and SNA DHCF/iX. |
| | |
| SSCPFM=USSSCS | Required for SNA IMF/iX. |
| | |
| VPACING=0 | Recommended for SNA IMF/iX keyboards and |
| | displays. |
| | |
| USSTAB | Must be specified for SNA IMF/iX only. Do not |
| | specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 |
| | products. |
| | |
| LOGAPPL | Can be used with SNA IMF/iX only. Do not |
| | specify for SNA NRJE/iX, or LU 6.2 products. |
| | |
-------------------------------------------------------------------------------
NTRI Requirements
This section defines the Network Control Program Token-Ring
Interconnection (NTRI) parameters that are necessary for a successful
connection between a host and MPE/iX SNA products.
The ACF/VTAM start parameters refer to the table and buffer size
definitions that ACF/VTAM uses to configure the resource requirements for
the network. Because start parameters apply to the whole network and are
not specific to the remote node, HP does not make any suggestions. HP
does recommend that the ACF/VTAM system programmer review the defined
values and make any adjustments for additional requirements put on the
system.
The tables in this section contain the parameters that HP allows for its
MPE/iX SNA products. Operands and values that you must specify are
noted. The tables also contain other operands that are allowed. For
operand definitions, refer to the section Parameter Definitions at the
end of this chapter, or to the appropriate NCP or VTAM manual for the
remote system.
WARNING The HP SNA products are emulations of IBM products. Thus, some
parameters will need particular values based on the requirements
of the HP products. Code these as specified or results are
unpredictable. Operands not listed are not allowed in the HP
SNA services definitions and therefore are not supported. Any
time spent solving problems related to incorrect configuration
of the host is billable to the customer on a time and materials
basis.
NTRI Parameters.
NTRI is an NCP function that allows a communications controller to be
attached to an IBM Token-Ring network. NTRI provides SNA subarea and
peripheral nodes with data link control services. Table 1-12 contains
NTRI parameters that are defined in NCP. Table 1-13 contains the VTAM
switched major node parameters for NTRI.
Table 1-12. MPE/iX SNA Products: NTRI Parameters
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| GROUP macro (physical) | |
| | |
- - -
| ECLTYPE=(PHYSICAL, | |
| | |
| PERIPHERAL) | Required by all MPE/iX SNA products. |
| | |
| COMPSWP=NO | Required for NCP version 5, release 2.1 and |
| | earlier. |
| | |
| DIAL=NO | |
| | |
| LNCTL=SDLC | Required by all MPE/iX SNA products. |
| | |
| TYPE=NCP | Required by all MPE/iX SNA products. |
| | |
- - -
| LINE macro | |
| | |
- - -
| ADAPTER=TIC1 or | |
| | |
| ADAPTER=TIC2 | Required by all MPE/iX SNA products. |
| | |
| ADDRESS=lnbr, FULL | Required by all MPE/iX SNA products. |
| | |
| PORTADD=n | Required by all MPE/iX SNA products. |
| | |
| LOCADD=4000abbbbbbb | Required by all MPE/iX SNA products. |
| | |
| RCVBUFC=n | Required by all MPE/iX SNA products. |
| | |
- - -
| PU macro | |
| | |
- - -
| puname PU | Required by all MPE/iX SNA products. |
| | |
- - -
| LU macro | |
| | |
- - -
| luname LU | Required by all MPE/iX SNA products. |
| | |
-------------------------------------------------------------------------------
Table 1-12. MPE/iX SNA Products: NTRI Parameters (cont.)
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| GROUP macro (logical) | |
| | |
- - -
| ECLTYPE=(LOGICAL, | |
| | |
| PERIPHERAL) | Required by all MPE/iX SNA products. |
| | |
| DIAL=YES | Required by all MPE/iX SNA products. |
| | |
| PHYPORT=n | Required by all MPE/iX SNA products. |
| | |
- - -
| LINE macro | |
| | |
- - -
| linename LINE | Required by all MPE/iX SNA products. |
| | |
- - -
| PU macro | |
| | |
- - -
| puname LU | Required by all MPE/iX SNA products. |
| | |
-------------------------------------------------------------------------------
NOTE Table 1-13 contains those parameters that are added to the BUILD
statement for NTRI. It does not contain all of the parameters that
are necessary for a complete BUILD statement.
Table 1-13. MPE/iX SNA Products: NTRI Switched Major Node
-------------------------------------------------------------------------------
| | |
| Operands and Values | Comments |
| | |
-------------------------------------------------------------------------------
| | |
| VBUILD macro | |
| | |
- - -
| TYPE=SWNET | Required by all MPE/iX SNA products. |
| | |
- - -
| PU macro | |
| | |
- - -
| puname PU | Required by all MPE/iX SNA products. Must match |
| | logical PU name. |
| | |
| ADDR=n | Required by all MPE/iX SNA products. |
| | |
| ANS=CONT | Required by all MPE/iX SNA products. |
| | |
| IDBLK=n | Required by all MPE/iX SNA products. |
| | |
| IDNUM=n | Required by all MPE/iX SNA products. |
| | |
| DISCNT=NO | |
| | |
| ISTATUS=ACTIVE | |
| | |
| MAXDATA | |
| | |
| MAXLU | |
| | |
| PUTYPE=2 | Required by all MPE/iX SNA products. |
| | |
| SRT | |
| | |
| XID=YES | Required for PU type 2.1 (T2.1). |
| | |
| MAXDATA=n | Required by all MPE/iX SNA products. |
| | |
- - -
| LU macro | |
| | |
- - -
| luname LU | Required by all MPE/iX SNA products. |
| | |
| LOCADDR=n | Required by all MPE/iX SNA products. Set to 0 |
| | for independent LUs. |
| | |
| DLOGMOD | Do not specify for SNA DHCF/iX. |
| | |
-------------------------------------------------------------------------------
MPE/iX 5.0 Documentation