HP 3000 Manuals

MPE/V SNA Product Configuration [ HP SNA Products Remote System Configuration Guide ] MPE/iX 5.0 Documentation


HP SNA Products Remote System Configuration Guide

MPE/V SNA Product Configuration 

This section covers remote system configuration requirements for the
following MPE/V SNA products:

   *   SNA Link

   *   SNA IMF

   *   SNA NRJE

   *   LU 6.2 Base

   *   LU 6.2 API

This section presents the requirements for ACF/NCP and ACF/VTAM for
switched and non-switched lines and logmode table parameters.

ACF/NCP and ACF/VTAM Requirements 

The ACF/VTAM start parameters refer to the table and buffer size
definitions that ACF/VTAM uses to configure the resource requirements for
the network.  Because start parameters apply to the entire VTAM domain
and are not specific to the remote node, HP does not make any
suggestions.  HP does recommend that the ACF/VTAM system programmer
review the defined values and make any adjustments for additional
requirements put on the system.

The tables in this section contain the parameters that HP allows for its
MPE/V SNA products.  Operands and values that you must specify are noted.
The tables also contain other operands that are allowed.  For operand
definitions, refer to the section Parameter Descriptions at the end of
this chapter, or to the appropriate NCP or VTAM manual for the remote
system.


WARNING The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis.
For MPE/V SNA products, more than one PU (Physical Unit) may be defined for an HP 3000 node. A maximum of eight PUs can be defined for each HP 3000 node. The number of PUs defined depends upon the number of SNA Link products installed. A maximum of 64 LUs (Logical Units) can be configured for each HP 3000 PU. For SNA NRJE/V, it is recommended that at least three LUs be defined. SNA IMF can support a maximum of 64 LUs. The LU 6.2 products can start a maximum of eight LUs. See the MPE/V SNA product documentation for more information on configuration requirements. Switched Lines. Tables 1-1 and 1-2 define the parameters necessary to connect MPE/V SNA products to a switched line. Any values listed that are not required are given as examples. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information. Table 1-1. MPE/V Products: NCP/VTAM Switched Line ------------------------------------------------------------------------------- | | | | Operands and Values | Comments | | | | ------------------------------------------------------------------------------- | | | | LUDRPOOL macro | | | | | - - - | NUMTYPE2=n | Required by all MPE/V SNA products. | | | | - - - | GROUP macro | | | | | - - - | DIAL=YES | Required by all MPE/V SNA products. | | | | | LNCTL=SDLC | Required by all MPE/V SNA products. | | | | | REPLYTO | | | | | | TEXTTO | | | | | | TYPE=NCP | Required by all MPE/V SNA products. | | | | - - - | LINE macro | | | | | - - - | ADDRESS=line addr | Required by all MPE/V SNA products. | | | | | SPEED=rate | Required by all MPE/V SNA products. | | | | | ANSWER=ON | Required by all MPE/V SNA products. | | | | | CALL=IN | Required by all MPE/V SNA products. | | | | | CLOCKNG=EXT | Required by all MPE/V SNA products. | | | | | DATRATE | | | | | | DUPLEX | | | | | | ETRATIO | | | | | | HDXSP | | | | | | INTPRI | | | | | | LPDATS | | | | | | MAXPU=1 | Required by all MPE/V SNA products. | | | | | NRZI=NO | Required by all MPE/V SNA products. | | | | | PAUSE | | | | | | POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. | | | Invalid for ACF/NCP version 1, release 3, and | | | later versions. | | | | | RETRIES=7 | | | | | | RING | | | | | | SPDSEL | | | | | | TRANSFER | | | | | | OWNER | | | | | ------------------------------------------------------------------------------- Table 1-2. MPE/V Products: VTAMLST Switched Major Node ------------------------------------------------------------------------------- | | | | Operands and Values | Comments | | | | ------------------------------------------------------------------------------- | | | | VBUILD macro | | | | | - - - | TYPE=SWNET | Required by all MPE/V SNA products. | | | | - - - | PU macro | | | | | - - - | puname PU | Required by all MPE/V SNA products. | | | | | ADDR=n | Required by all MPE/V SNA products. | | | | | ANS | Required by all MPE/V SNA products. | | | | | IDBLK=023 | Required for LU 6.2 API/V, LU 6.2 Base/V, SNA | | | IMF/V, and SNA NRJE/V. | | | | | IDNUM=n | Required by all MPE/V SNA products. | | | | | DISCNT=NO | | | | | | ISTATUS | | | | | | MAXLU | | | | | | PUTYPE=2 | Required by all MPE/V SNA products. | | | | | SRT | | | | | | XID=YES | Required for node type 2.1 (T2.1). | | | | - - - | LU macro | | | | | - - - | luname LU | Required by all MPE/V SNA products. | | | | | LOCADDR=n | Required by all MPE/V SNA products. Set to 0 | | | for independent LUs. | | | | | BATCH=YES | Recommended for SNA NRJE/V on applicable | | | versions of ACF/NCP. This parameter is not | | | supported for ACF/NCP version 5 or later. | | | | | DLOGMOD | | | | | | ISTATUS | | | | | | MODETAB=HPMODTAB | | | | | | PACING=0 | Recommended for SNA IMF/V | | | | | SSCPFM=FSS | Required for LU 6.2 API/V, LU 6.2 Base/V, and | | | SNA NRJE/V. | | | | | SSCPFM=USSSCS | Required for SNA IMF/V. | | | | | VPACING=0 | Recommended for SNA IMF/V keyboards and | | | displays. | | | | | USSTAB | Must be specified for SNA IMF/V only. Do not | | | specify for SNA NRJE/V or LU 6.2 products. | | | | | LOGAPPL | Can be used with SNA IMF/V only. Do not specify | | | for SNA NRJE/V. | | | | ------------------------------------------------------------------------------- Non-Switched Lines. Table 1-3 defines the parameters necessary to connect MPE/V SNA products to a leased (non-switched) line. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information. Table 1-3. MPE/V Products: NCP/VTAM Non-Switched Line ------------------------------------------------------------------------------- | | | | Operands and Values | Comments | | | | ------------------------------------------------------------------------------- | | | | GROUP macro | | | | | - - - | DIAL=NO | Required by all MPE/V SNA products. | | | | | LNCTL=SDLC | Required by all MPE/V SNA products. | | | | | REPLYTO | | | | | | TEXTTO | | | | | | TYPE=NCP | Required by all MPE/V SNA products. | | | | - - - | LINE macro | | | | | - - - | ADDRESS=line addr | Required by all MPE/V SNA products. | | | | | SPEED=rate | Required by all MPE/V SNA products. | | | | | CLOCKNG=EXT | Required by all MPE/V SNA products. | | | | | DATRATE | | | | | | DUPLEX | | | | | | ETRATIO | | | | | | HDXSP | | | | | | INTPRI | | | | | | LPDATS | | | | | | MAXPU | | | | | | NRZI=NO | Required for SNA NRJE/V, SNA IMF/V, LU 6.2 | | | Base/V, and LU 6.2 API/V. | | | | | PAUSE | | | | | | POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. | | | Invalid for ACF/NCP version 1, release 3, and | | | later versions. | | | | | RETRIES | | | | | | SERVLIM | | | | | | SPDSEL | | | | | | TRANSFER | | | | | | OWNER | | | | | ------------------------------------------------------------------------------- Table 1-3. MPE/V Products: NCP/VTAM Non-Switched Line (cont.) ------------------------------------------------------------------------------- | | | | Operands and Values | Comments | | | | ------------------------------------------------------------------------------- | | | | SERVICE macro | | | | | - - - | ORDER | | | | | | MAXLIST | | | | | - - - | PU macro | | | | | - - - | puname PU | Required by all MPE/V SNA products. | | | | | ADDR=n | Required by all MPE/V SNA products. | | | | | ANS | | | | | | DISCNT=NO | | | | | | IRETRY | | | | | | ISTATUS | | | | | | MAXDATA=265 | Required by all MPE/V SNA products. | | | | | or MAXDATA=521 | | | | | | MAXOUT=7 | | | | | | PASSLIM=7 | | | | | | PUTYPE=2 | Required by all MPE/V SNA products. | | | | | RETRIES=7 | | | | | | SRT | | | | | | XID=YES | Required for type 2.1 node. | | | | - - - | LU macro | | | | | - - - | luname LU | Required by all MPE/V SNA products. | | | | | LOCADDR=n | Required by all MPE/V SNA products. Set to 0 | | | for independent LUs. | | | | | BATCH=YES | Recommended for SNA NRJE/V on applicable | | | versions of ACF/NCP. This parameter is not | | | supported for ACF/NCP version 5 or later. | | | | | DLOGMOD | | | | | | ISTATUS | | | | | | MODETAB=HPMODTAB | | | | | | PACING=0 | Recommended for SNA IMF/V keyboards and | | | displays. | | | | | SSCPFM=FSS | Required for LU 6.2 API/V, LU 6.2 Base/V, and | | | SNA NRJE/V. | | | | | SSCPFM=USSSCS | Required for SNA IMF/V. | | | | | VPACING=0 | Recommended for SNA IMF/V keyboards and | | | displays. | | | | | USSTAB | Must be specified for SNA IMF/V only. Do not | | | specify for SNA NRJE/V or LU 6.2 products. | | | | | LOGAPPL | Can be used with SNA IMF/V only. Do not specify | | | for SNA NRJE/V. | | | | ------------------------------------------------------------------------------- Logmode Table Requirements The Logmode table definitions determine the operating characteristics of the session with a host LU--the bind parameters. The tables in this section define the Logmode table parameters necessary for MPE/V SNA products. Tables 1-4, 1-5, and 1-6 contain Logmode table parameters required for SNA NRJE/V for the JES2, JES3, and POWER job entry subsystems. Table 1-7 contains the Logmode table parameters required for SNA IMF/V. Table 1-8 contains the Logmode table parameters required for the LU 6.2 products, LU 6.2 Base/V and LU 6.2 API/V. Table 1-4. SNA NRJE/V: JES2 Logmode Table ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | COMPROT | 7080 | Required value. | | | | | - - - - | FMPROF | 03 | Required value. | | | | | - - - - | LOGMODE | MODENRJE | Suggested value. | | | | | - - - - | PSNDPAC | 3 | Suggested value. | | | | | - - - - | PRIPROT | B1 or B3 | Required value. | | | | | | | B3 | | | | | | - - - - | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | | - - - - | RUSIZES* | 8585 | Required value. | | | | | - - - - | SECPROT | A3 | Suggested value. | | | | | - - - - | SSNDPAC | 3 | Suggested value. | | | | | - - - - | SRCVPAC | 3 | Suggested value. | | | | | - - - - | TSPROF | 03 | Required value. | | | | | ---------------------------------------------------------------------------------- * See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values. Table 1-5. SNA NRJE/V: JES3 Logmode Table ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | COMPROT | 7080 | Required value. | | | | | | FMPROF | 03 | Required value. | | | | | | LOGMODE | MODENRJE | Suggested value. | | | | | | PSNDPAC | 3 | Suggested value. | | | | | | PRIPROT | A1, A3, B1, or B3 | Required value. | | | | | | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | | | RUSIZES* | 8686 | Required value. | | | | | | SECPROT | A1 or A3 | Required value. | | | | | | SSNDPAC | 3 | Suggested value. | | | | | | SRCVPAC | 3 | Suggested value. | | | | | | TSPROF | 03 | Required value. | | | | | ---------------------------------------------------------------------------------- * See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values. Table 1-6. SNA NRJE/V: POWER Logmode Table ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | COMPROT | 7080 | Required value. | | | | | - - - - | FMPROF | 03 | Required value. | | | | | - - - - | LOGMODE | MODENRJE | Suggested value. | | | | | - - - - | PSNDPAC | 3 | Suggested value. | | | | | - - - - | PRIPROT | A3 | Required value. | | | | | | | B3 | | | | | | - - - - | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | | - - - - | RUSIZES* | 8585 | Required value. | | | | | - - - - | SECPROT | A1 | Required value. | | | | | - - - - | SSNDPAC | 3 | Suggested value. | | | | | - - - - | SRCVPAC | 3 | Suggested value. | | | | | - - - - | TSPROF | 03 | Required value. | | | | | - - - - ---------------------------------------------------------------------------------- * See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values. Table 1-7. SNA IMF/V: Logmode Table ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | COMPROT | 3080 | Required value. | | | | | - - - - | FMPROF | 03 | Required value. | | | | | - - - - | LOGMODE | IMFLU1 for LU.T1 | Suggested value. | | | | | | | IMF1920 for LU.T2 with 1920 | | | | size screen | | | | | | | | IMF480 for LU.T2 with 480 size | | | | screen | | | | | | | | IMF3440 for LU.T2 with 3440 | | | | size screen | | | | | | | | IMFLU3 for LU.T3 | | | | | | - - - - | PSNDPAC | 3 | Suggested value. | | | | | - - - - | PRIPROT | 11, 21, 31, A1, or B1 | Required value. | | | | | - - - - | PSERVIC | Printer (LU.T1): | Suggested values. | | | 01000000E100000000000000 | | | | | | | | Terminal (LU.T2) and screen | | | | size of 1920: | | | | | | | | 020000000000000000000200 | | | | | | | | 020000000000185000007E00 | | | | | | | | 020000000000185018507F00 | | | | | | | | Terminal (LU.T2) and screen | | | | size of 480: | | | | | | | | 020000000000000000000100 | | | | | | | | 0200000000000C280C287E00 | | | | | | | | 0200000000000C280C287F00 | | | | | | | | Terminal (LU.T2) and screen | | | | size of 3440: | | | | | | | | 0200000000002B5000007E00 | | | | | | | | 02000000000018502B507E00 | | | | | | | | Printer (LU.T3): | | | | 030000000000000000000200 | | | | | | ---------------------------------------------------------------------------------- Table 1-7. SNA IMF/V: Logmode Table (cont.) ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | RUSIZES* | Must be 8989 or less. | Suggested value. | | | | | | | 8587-LU.T1 Printer | | | | | | | | 8989-LU.T2 Terminal | | | | | | - - - - | SECPROT | 90 (LU.T1/T3 printer), A0, or | Required value. | | | B0 (LU.T2 display station) | | | | | | - - - - | SSNDPAC | 3-LU.T1 and LU.T3 printers | | | | | | | | 0-LU.T2 terminals | Suggested value. | | | | | - - - - | SRCVPAC | 3 | Suggested value. | | | | | - - - - | TSPROF | 03 | Required value. | | | | | ---------------------------------------------------------------------------------- * See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values. Table 1-8. MPE/V LU 6.2: Logmode Table ---------------------------------------------------------------------------------- | | | | | Required | Values (hexadecimal) | Comments | | Parameters | | | | | | | ---------------------------------------------------------------------------------- | | | | | LOGMODE | MODE62 | Suggested value. | | | | | - - - - | PSERVIC | 000000000000000000000000 | Suggested value. | | | | | - - - - | PSNDPAC | 3 for LU 6.2 Base/V | Suggested value. | | | | | | | 3 for LU 6.2 API/V | | | | | | - - - - | SSNDPAC | 0 | Suggested value. | | | | | - - - - | SRCVPAC | 0 | Suggested value. | | | | | ----------------------------------------------------------------------------------
NOTE The values in table 1-8 are for node type 2.0 (T2.0) only. For T2.1 LUs (that is, independent LUs), the actual logmode value is not important, as long as the logmode is a valid one.


MPE/iX 5.0 Documentation