HP 3000 Manuals

SNACONTROL Error Messages [ SNA Link/iX Node Manager's Guide ] MPE/iX 5.0 Documentation


SNA Link/iX Node Manager's Guide

SNACONTROL Error Messages 

Listed below are the error messages that can be returned by SNACONTROL
commands.  They are listed in numerical order according to message
number.  These messages are written to $STDLIST; they are not logged.

NMS messages might also be returned in response to SNACONTROL commands.
For a list of those messages and their meanings, see the Using the Node 
Management Services Utilities manual.

SNACIERR 1   MESSAGE      SNA COMMAND ESCAPE CODE: SUBSYS=SubsysID 
                          INFO=ErrorNum.  (SNACIERR 1)

             CAUSE        This message provides troubleshooting
                          information.  It is added to many SNA command
                          interpreter (CI) error messages and aids in
                          locating the possible source of a problem.

             ACTION       None.

--------------------------------------------------------------------------

SNACIERR 2   MESSAGE      SNA TRANSPORT NOT PROPERLY INSTALLED. CHECK
                          VERSIONS. (SNACIERR 2)

             CAUSE        A version check of SNA Transport failed because
                          of differences in module versions or because of
                          missing modules.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 3   MESSAGE      TRACE ALREADY IN PROGRESS FOR THIS ENTITY.
                          (SNACIERR 3)

             CAUSE        The SNACONTROL TRACEON command was issued for an
                          LUName or link that is already executing
                          tracing.

             ACTION       If you are turning on intrinsic tracing, ensure
                          that you are specifying the correct LUName in
                          the SNACONTROL TRACEON command.  If you are,
                          issue the SNACONTROL STATUS command to see
                          whether tracing is already on for that LU. If
                          you are turning on link-level tracing, ensure
                          that you are specifying the LINKTRACE parameter
                          in the SNACONTROL TRACEON command.

--------------------------------------------------------------------------

SNACIERR 4   MESSAGE      TRACE NOT IN PROGRESS FOR THIS ENTITY. (SNACIERR
                          4)

             CAUSE        The SNACONTROL TRACEOFF command was issued for
                          an LUName or link that is not executing tracing.

             ACTION       If you are turning off intrinsic tracing, ensure
                          that you are specifying the correct LUName in
                          the SNACONTROL TRACEOFF command.  If you are,
                          issue the SNACONTROL STATUS command to see
                          whether tracing is already off for that LU. If
                          you are turning off link-level tracing, ensure
                          that you are specifying the LINKTRACE parameter
                          in the SNACONTROL TRACEOFF command.

             CAUSE        The SNACONTROL TRACEOFF command was issued after
                          the SNA node has started to shut down.

             ACTION       None; tracing is automatically turned off when a
                          node is shutting down.

--------------------------------------------------------------------------

SNACIERR 5   MESSAGE      COULDN'T OPEN TRACE FILE. (SNACIERR 5)

             CAUSE        An illegal TraceFile parameter was specified in
                          an SNACONTROL START or SNACONTROL TRACEON
                          command.

             ACTION       Ensure that the specified TraceFile is a legal
                          file name (see the description of the command
                          you issued).

             CAUSE        The user who issued the command might not have
                          the proper system capabilities.

             ACTION       Verify that the user has the proper system
                          capabilities.

             CAUSE        A trace manager problem might exist.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 6   MESSAGE      COULDN'T CLOSE TRACE FILE. (SNACIERR 6)

             CAUSE        A trace manager problem might exist.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 7   MESSAGE      COULDN'T GET NODE CONFIGURATION DATA. (SNACIERR
                          7)

             CAUSE        The network manager was unable to get the
                          configuration data for the node from the
                          NMCONFIG.PUB.SYS configuration file.

             ACTION       Use NMMGR to verify that the configuration file
                          is valid.  If it is, write down the
                          circumstances and call your Hewlett-Packard
                          support contact.

--------------------------------------------------------------------------

SNACIERR 8   MESSAGE      COULDN'T OPEN CONFIGURATION FILE. (SNACIERR 8)

             CAUSE        The NMCONFIG.PUB.SYS configuration file does not
                          exist.

             ACTION       Use NMMGR to verify that the configuration file
                          exists.  If it does, write down the
                          circumstances and call your Hewlett-Packard
                          support contact.

             CAUSE        The NMCONFIG.PUB.SYS configuration file has been
                          corrupted, and the file system cannot open it.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 9   MESSAGE      NODE SPECIFIED NOT ACTIVE. (SNACIERR 9)

             CAUSE        An SNACONTROL command was issued for an SNA node
                          that is not active.  The node either was never
                          started or has been stopped.

             ACTION       Issue the SNACONTROL STATUS command to see
                          whether the node is active.  If the node is not
                          active, issue the SNACONTROL START command for
                          the node.  Once the node is active, reissue the
                          first SNACONTROL command.  If the error still
                          occurs, write down the circumstances and call
                          your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 10  MESSAGE      NODE SPECIFIED IS ALREADY ACTIVE. (SNACIERR 10)

             CAUSE        The SNACONTROL START command was issued for a
                          node that is already active.

             ACTION       Ensure that you are specifying the correct
                          NodeName in the SNACONTROL START command.

--------------------------------------------------------------------------

SNACIERR 11  MESSAGE      NODE SPECIFIED NOT CONFIGURED. (SNACIERR 11)

             CAUSE        No configuration data was found for the SNA node
                          specified in the command.

             ACTION       Use NMMGR or the configuration file critical
                          summary to verify that the configuration file
                          NMCONFIG.PUB.SYS contains data for the specified
                          node.  If it does, ensure that the SNACONTROL
                          command was issued correctly.

--------------------------------------------------------------------------

SNACIERR 12  MESSAGE      MORE THAN ONE NODE IN CONFIGURATION. PLEASE
                          SPECIFY. (SNACIERR 12)

             CAUSE        An SNACONTROL command was issued without a
                          NodeName parameter.  Since more than one node is
                          configured, the NodeName must be specified.

             ACTION       Reissue the command with the correct NodeName 
                          specified.

--------------------------------------------------------------------------

SNACIERR 13  MESSAGE      NO SNA NODE IS CONFIGURED IN NMCONFIG.PUB.SYS.
                          (SNACIERR 13)

             CAUSE        An SNACONTROL START command was issued without a
                          NodeName parameter.  If this is done when the
                          configuration file (NMCONFIG.PUB.SYS) contains
                          data for only one node, that node is started, by
                          default.  However, no node data was found in the
                          configuration file when the command was issued.
                          So, the default could not be used.

             ACTION       Use NMMGR or the configuration file critical
                          summary to verify that the configuration file
                          contains data for at least one SNA node.  If it
                          does, ensure that the SNACONTROL START command
                          was issued correctly.  If the configuration file
                          does not contain data for at least one node,
                          configure the appropriate node and then reissue
                          the SNACONTROL START command.

--------------------------------------------------------------------------

SNACIERR 14  MESSAGE      UNABLE TO OPEN BUFFER POOL. (SNACIERR 14)

             CAUSE        An internal system error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 16  MESSAGE      UNABLE TO CREATE PORTS FOR SNA SERVERS.
                          (SNACIERR 16)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 17  MESSAGE      COULDN'T START SNASSV PROCESS. (SNACIERR 17)

             CAUSE        Either the SNASSV program module does not exist
                          or an internal error has occurred.

             ACTION       Check the installation of SNA Transport.  Use
                          NMMAINT or the SNACONTROL VERSION command to
                          verify that SNASSV.PUB.SYS is present and that
                          the version is correct.  If it is and the error
                          still occurs, write down the circumstances and
                          call your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 18  MESSAGE      COULDN'T ADD SNACSC'S PORT TO NMMON DICT.
                          (SNACIERR 18)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 19  MESSAGE      UNABLE TO OBTAIN STARTUP INFO FROM SDLC.
                          (SNACIERR 19)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 20  MESSAGE      UNABLE TO OPEN LINK. (SNACIERR 20)

             CAUSE        For an SDLC link, (1) the PSI card is not
                          installed, (2) the PSI card is installed
                          incorrectly, or (3) the physical path is not
                          configured.

             ACTION       Ensure that the PSI card is installed correctly,
                          and use NMMGR or the configuration file critical
                          summary to verify that the Physical Path field
                          contains the correct information.  If the error
                          still occurs, write down the circumstances and
                          call your Hewlett-Packard support contact.

             CAUSE        For an X.25 link, (1) X.25/XL System Access is
                          not active, (2) the necessary hardware is not
                          installed correctly, (3) the SNA/X.25 Link
                          configuration and the X.25/XL System Access
                          configuration are not compatible with each
                          other, (4) no SVCs are available, or (5) the PVC
                          number is not in the configured PVC range in the
                          DTC X.25 configuration.

             ACTION       Issue the NETCONTROL command to verify the X.25
                          link status and start the link if necessary.
                          When you check the link's status, verify that
                          the X.25 Level 1 status is "connected," Level 2
                          is "on," and Level 3 is "ready." If the link
                          status is correct, ensure that the SNA/X.25 Link
                          configuration and the X.25/XL System Access
                          configuration are compatible with each other and
                          with the X.25 configuration on the DTC (see
                          chapter 2 of this manual).  If the error still
                          occurs, write down the circumstances and call
                          your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 21  MESSAGE      COULDN'T OPEN LOG FILE. (SNACIERR 21)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 22  MESSAGE      COULDN'T START SNACSC PROCESS. (SNACIERR 22)

             CAUSE        Either the SNACSC program module does not exist
                          or an internal error has occurred.

             ACTION       Check the installation of SNA Transport.  Use
                          NMMAINT or the SNACONTROL VERSION command to
                          verify that SNACSC.PUB.SYS is present and that
                          the version is correct.  If the error still
                          occurs, write down the circumstances and call
                          your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 23  MESSAGE      BAD START REPLY FROM SNACSC. (SNACIERR 23)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 24  MESSAGE      COULDN'T SEND STOP REQUEST TO SNACSC. (SNACIERR
                          24)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 25  MESSAGE      UNABLE TO ADD NODENAME TO NODE DIRECTORY.
                          (SNACIERR 25)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 26  MESSAGE      COULDN'T RELEASE NODE DIRECTORY. (SNACIERR 26)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 27  MESSAGE      COULDN'T GET DIRECTORY INFO. (SNACIERR 27)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 28  MESSAGE      THE LUNAME MUST BE SPECIFIED. (SNACIERR 28)

             CAUSE        The ROUTE, HSCB, or LURECORD parameter was
                          specified in the SNACONTROL STATUS command, but
                          no LUName parameter was specified.

             ACTION       Reissue the SNACONTROL STATUS command with the
                          appropriate LUName parameter specified.

--------------------------------------------------------------------------

SNACIERR 29  MESSAGE      COULDN'T FIND LUNAME SPECIFIED. (SNACIERR 29)

             CAUSE        The LUName parameter specified in an SNACONTROL
                          STATUS, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, or SNACONTROL TRACEON command could
                          not be found in the NMCONFIG.PUB.SYS
                          configuration file.

             ACTION       Ensure that the LUName is spelled correctly, and
                          use NMMGR or the configuration file critical
                          summary to ensure that the LU is actually
                          configured.
--------------------------------------------------------------------------

SNACIERR 32  MESSAGE      COULDN'T GET AN NCB FOR THIS SNA NODE. (SNACIERR
                          32)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 33  MESSAGE      NO SUCH ACTIVE SESSION. (SNACIERR 33)

             CAUSE        An LUName for which no active session exists was
                          specified in an SNACONTROL STOPSESS or
                          SNACONTROL TRACEOFF command.

             ACTION       Issue the SNACONTROL STATUS command to see
                          whether the session for the specified LUName 
                          exists.  If it does, reissue the first command.
                          If the error still occurs, write down the
                          circumstances and call your Hewlett-Packard
                          support contact.

--------------------------------------------------------------------------

SNACIERR 34  MESSAGE      CAN'T SPECIFY NODENAME HERE. (SNACIERR 34)

             CAUSE        The NodeName parameter was specified in an
                          SNACONTROL VERSION command.  NodeName is not a
                          valid parameter for that command.

             ACTION       Reissue the SNACONTROL VERSION command without a
                          NodeName parameter.

--------------------------------------------------------------------------

SNACIERR 36  MESSAGE      CAN'T SPECIFY STYPE HERE. (SNACIERR 36)

             CAUSE        The STYPE parameter was specified in an
                          SNACONTROL command; none of the commands uses
                          STYPE.

             ACTION       Reissue the command without an STYPE parameter.

--------------------------------------------------------------------------

SNACIERR 37  MESSAGE      CAN'T SPECIFY STOP TYPE HERE. (SNACIERR 37)

             CAUSE        The StopType parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STATUS, SNACONTROL TRACEOFF,
                          SNACONTROL TRACEON, or SNACONTROL VERSION
                          command.  None of these commands uses StopType.

             ACTION       Reissue the command without a StopType 
                          parameter.

--------------------------------------------------------------------------

SNACIERR 39  MESSAGE      CAN'T SPECIFY TRACE HERE. (SNACIERR 39)

             CAUSE        The TRACE parameter was specified in an
                          SNACONTROL command; none of the commands uses
                          TRACE.

             ACTION       Reissue the command without a TRACE parameter.

--------------------------------------------------------------------------

SNACIERR 41  MESSAGE      CAN'T SPECIFY ERROPT HERE. (SNACIERR 41)

             CAUSE        The ERROPT parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL STATUS,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          ERROPT.

             ACTION       Reissue the command without an ERROPT parameter.

--------------------------------------------------------------------------

SNACIERR 42  MESSAGE      CAN'T SPECIFY NCB HERE. (SNACIERR 42)

             CAUSE        The NCB parameter was specified in an SNACONTROL
                          AUTODIAL, SNACONTROL START, SNACONTROL STOP,
                          SNACONTROL STOPSESS, SNACONTROL TRACEOFF,
                          SNACONTROL TRACEON, or SNACONTROL VERSION
                          command.  None of these commands uses NCB.

             ACTION       Reissue the command without an NCB parameter.

--------------------------------------------------------------------------

SNACIERR 43  MESSAGE      CAN'T SPECIFY HSCB HERE. (SNACIERR 43)

             CAUSE        The HSCB parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          HSCB.

             ACTION       Reissue the command without an HSCB parameter.

--------------------------------------------------------------------------

SNACIERR 44  MESSAGE      CAN'T SPECIFY ROUTE HERE. (SNACIERR 44)

             CAUSE        The ROUTE parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          ROUTE.

             ACTION       Reissue the command without a ROUTE parameter.

--------------------------------------------------------------------------

SNACIERR 45  MESSAGE      CAN'T SPECIFY DEBUG HERE. (SNACIERR 45)

             CAUSE        The DEBUG parameter was specified in an
                          SNACONTROL command; none of the commands uses
                          DEBUG.

             ACTION       Reissue the command without a DEBUG parameter.

--------------------------------------------------------------------------

SNACIERR 46  MESSAGE      SNA SWITCH FROM COMPAT. MODE TO NATIVE MODE
                          ERROR. (SNACIERR 46)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 47  MESSAGE      LINK TRACE SIO REQUEST FAILURE. (SNACIERR 47)

             CAUSE        Link-level tracing is already on for the node.

             ACTION       None.

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 48  MESSAGE      LINK TRACE DISABLE REQUEST FAILURE. (SNACIERR
                          48)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 49  MESSAGE      LINK TRACE FILE OPEN FAILURE. (SNACIERR 49)

             CAUSE        An illegal TraceFile parameter was specified in
                          an SNACONTROL START or SNACONTROL TRACEON
                          command.

             ACTION       Ensure that the specified TraceFile is a valid
                          file name (see the description of the command
                          you issued).

             CAUSE        The user who issued the command might not have
                          the proper system capabilities.

             ACTION       Verify that the user has node manager (NM)
                          capabilities.

             CAUSE        A trace manager problem might exist.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 50  MESSAGE      MAX DATA (PIU) TOO LARGE. (SNACIERR 50)

             CAUSE        The value specified in the MAX DATA field of the
                          "SNA Node Configuration:  PU Data" screen is too
                          large.

             ACTION       Enter a valid value in the MAX DATA field.

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 51  MESSAGE      CAN'T SPECIFY LUNAME HERE. (SNACIERR 51)

             CAUSE        The LUName parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, or SNACONTROL VERSION command.
                          None of these commands uses LUName.

             ACTION       Reissue the command without an LUName parameter.

--------------------------------------------------------------------------

SNACIERR 52  MESSAGE      CAN'T SPECIFY LINKTRACE HERE. (SNACIERR 52)

             CAUSE        The LINKTRACE parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL STATUS,
                          SNACONTROL STOP, SNACONTROL STOPSESS, or
                          SNACONTROL VERSION command.  None of these
                          commands uses LINKTRACE.

             ACTION       Reissue the command without a LINKTRACE
                          parameter.

--------------------------------------------------------------------------

SNACIERR 53  MESSAGE      CAN'T SPECIFY NODETRACE HERE. (SNACIERR 53)

             CAUSE        The NODETRACE parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL STATUS,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          NODETRACE.

             ACTION       Reissue the command without a NODETRACE
                          parameter.

--------------------------------------------------------------------------

SNACIERR 54  MESSAGE      CAN'T SPECIFY INTRINSIC HERE. (SNACIERR 54)

             CAUSE        The INTRINSIC parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STATUS, SNACONTROL STOP, SNACONTROL
                          STOPSESS, or SNACONTROL VERSION command.  None
                          of these commands uses INTRINSIC.

             ACTION       Reissue the command without an INTRINSIC
                          parameter.

--------------------------------------------------------------------------

SNACIERR 55  MESSAGE      TRACE COMMAND IGNORED. PLEASE SPECIFY TRACE
                          TYPE. (SNACIERR 55)

             CAUSE        The SNACONTROL TRACEOFF or SNACONTROL TRACEON
                          command was issued, but a valid trace type was
                          not specified.

             ACTION       Reissue the command with the LINKTRACE or
                          INTRINSIC parameters.

--------------------------------------------------------------------------

SNACIERR 59  MESSAGE      CAN'T SPECIFY "LINK" HERE. (SNACIERR 59)

             CAUSE        The LINK parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK.

             ACTION       Reissue the command without a LINK parameter.

--------------------------------------------------------------------------

SNACIERR 60  MESSAGE      CAN'T SPECIFY "LINK=A" HERE. (SNACIERR 60)

             CAUSE        The LINK=A parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=A.

             ACTION       Reissue the command without a LINK=A parameter.

--------------------------------------------------------------------------

SNACIERR 61  MESSAGE      CAN'T SPECIFY "LINK=C" HERE. (SNACIERR 61)

             CAUSE        The LINK=C parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=C.

             ACTION       Reissue the command without a LINK=C parameter.

--------------------------------------------------------------------------

SNACIERR 62  MESSAGE      CAN'T SPECIFY "LINK=L" HERE. (SNACIERR 62)

             CAUSE        The LINK=L parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=L.

             ACTION       Reissue the command without a LINK=L parameter.

--------------------------------------------------------------------------

SNACIERR 63  MESSAGE      CAN'T SPECIFY "LINK=S" HERE. (SNACIERR 63)

             CAUSE        The LINK=S parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=S.

             ACTION       Reissue the command without a LINK=S parameter.

--------------------------------------------------------------------------

SNACIERR 64  MESSAGE      CAN'T SPECIFY "LINK=D" HERE. (SNACIERR 64)

             CAUSE        The LINK=D parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=D.

             ACTION       Reissue the command without a LINK=D parameter.

--------------------------------------------------------------------------

SNACIERR 65  MESSAGE      CAN'T SPECIFY "LINK=R" HERE. (SNACIERR 65)

             CAUSE        The LINK=R parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=R.

             ACTION       Reissue the command without a LINK=R parameter.

--------------------------------------------------------------------------

SNACIERR 66  MESSAGE      CAN'T SPECIFY "LINK=ALL" HERE. (SNACIERR 66)

             CAUSE        The LINK=ALL parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=ALL.

             ACTION       Reissue the command without a LINK=ALL
                          parameter.

--------------------------------------------------------------------------

SNACIERR 67  MESSAGE      CAN'T SPECIFY "LINK=CONF" HERE. (SNACIERR 67)

             CAUSE        The LINK=CONF parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=CONF.

             ACTION       Reissue the command without a LINK=CONF
                          parameter.

--------------------------------------------------------------------------

SNACIERR 68  MESSAGE      CAN'T SPECIFY "LINK=LINK" HERE. (SNACIERR 68)

             CAUSE        The LINK=LINK parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=LINK.

             ACTION       Reissue the command without a LINK=LINK
                          parameter.

--------------------------------------------------------------------------

SNACIERR 69  MESSAGE      CAN'T SPECIFY "LINK=STAT" HERE. (SNACIERR 69)

             CAUSE        The LINK=STAT parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=STAT.

             ACTION       Reissue the command without a LINK=STAT
                          parameter.

--------------------------------------------------------------------------

SNACIERR 70  MESSAGE      CAN'T SPECIFY "LINK=DIAG" HERE. (SNACIERR 70)

             CAUSE        The LINK=DIAG parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=DIAG.

             ACTION       Reissue the command without a LINK=DIAG
                          parameter.

--------------------------------------------------------------------------

SNACIERR 71  MESSAGE      CAN'T SPECIFY "LINK=RESET" HERE. (SNACIERR 71)

             CAUSE        The LINK=RESET parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=RESET.

             ACTION       Reissue the command without a LINK=RESET
                          parameter.

--------------------------------------------------------------------------

SNACIERR 72  MESSAGE      CAN'T SPECIFY "LINK=CONFIGURATION" HERE.
                          (SNACIERR 72)

             CAUSE        The LINK=CONFIGURATION parameter was specified
                          in an SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=CONFIGURATION.

             ACTION       Reissue the command without a LINK=CONFIGURATION
                          parameter.

--------------------------------------------------------------------------

SNACIERR 73  MESSAGE      CAN'T SPECIFY "LINK=LINKSTATE" HERE. (SNACIERR
                          73)

             CAUSE        The LINK=LINKSTATE parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=LINKSTATE.

             ACTION       Reissue the command without a LINK=LINKSTATE
                          parameter.

--------------------------------------------------------------------------

SNACIERR 74  MESSAGE      CAN'T SPECIFY "LINK=STATISTICS" HERE. (SNACIERR
                          74)

             CAUSE        The LINK=STATISTICS parameter was specified in
                          an SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=STATISTICS.

             ACTION       Reissue the command without a LINK=STATISTICS
                          parameter.

--------------------------------------------------------------------------

SNACIERR 75  MESSAGE      CAN'T SPECIFY "LINK=DIAGSTATS" HERE. (SNACIERR
                          75)

             CAUSE        The LINK=DIAGSTATS parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LINK=DIAGSTATS.

             ACTION       Reissue the command without a LINK=DIAGSTATS
                          parameter.

--------------------------------------------------------------------------

SNACIERR 76  MESSAGE      MESSAGE CATALOG FILE (CATSNA.PUB.SYS) OPEN
                          ERROR. (SNACIERR 76)

             CAUSE        The SNA message catalog CATSNA.PUB.SYS is
                          missing, or is not in the correct format.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 77  MESSAGE      COULDN'T CREATE SNA'S PORT FACILITY PROCESS.
                          (SNACIERR 77)

             CAUSE        A call to Create_pfp to create SNA's port
                          facility process during SNACSC's initialization
                          failed.  This is an internal error.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 78  MESSAGE      COULDN'T GET THE PIN OF SNA'S PORT FACILITY
                          PROCESS. (SNACIERR 78)

             CAUSE        A call to Port_info to obtain the Process
                          Identification Number (PIN) of SNA's port
                          facility process failed.  This is an internal
                          error.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 79  MESSAGE      BAD TRACE FILE SIZE SPECIFIED. (SNACIERR 79)

             CAUSE        An illegal NumRecords value was specified for
                          the TFILESIZE parameter in an SNACONTROL START
                          or SNACONTROL TRACEON command.

             ACTION       Ensure that the specified NumRecords value is
                          within the acceptable range (see the description
                          of the command you issued).

--------------------------------------------------------------------------

SNACIERR 80  MESSAGE      SNA/X.25 NOT PROPERLY INSTALLED. CHECK VERSIONS.

                          (SNACIERR 80)

             CAUSE        A version check of SNA/X.25 Link failed because
                          of differences in module versions or because of
                          missing modules.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 81  MESSAGE      AN ATTEMPT TO SEE IF SNA/X.25 IS INSTALLED
                          FAILED. (SNACIERR 81)

             CAUSE        A call to FLabelInfo for the file SNAX25.PUB.SYS
                          failed with a file system error.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 82  MESSAGE      NMCAT.PUB.SYS OPEN FAILURE. (SNACIERR 82)

             CAUSE        SNA Transport cannot open the message catalog
                          NMCAT.PUB.SYS to enable the SDLC link to display
                          link status information.

             ACTION       Use the MPE FLIST command to ensure that
                          NMCAT.PUB.SYS is installed on your system.  If
                          it is, write down the circumstances and call
                          your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 83  MESSAGE      LINK STATUS DISPLAY ERROR. (SNACIERR 83)

             CAUSE        An attempt to display the X.25 link status
                          information failed.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 84  MESSAGE      CAN'T SPECIFY LURECORD HERE. (SNACIERR 84)

             CAUSE        The LURECORD parameter was specified in an
                          SNACONTROL AUTODIAL, SNACONTROL START,
                          SNACONTROL STOP, SNACONTROL STOPSESS, SNACONTROL
                          TRACEOFF, SNACONTROL TRACEON, or SNACONTROL
                          VERSION command.  None of these commands uses
                          LURECORD.

             ACTION       Reissue the command without an LURECORD
                          parameter.

--------------------------------------------------------------------------

SNACIERR 85  MESSAGE      CAN'T SPECIFY FILESIZE HERE. (SNACIERR 85)

             CAUSE        A file size was specified as a parameter to an
                          SNACONTROL command.

             ACTION       Do not specify a file size as a parameter to a
                          command.

--------------------------------------------------------------------------

SNACIERR 86  MESSAGE      AN SNA LINK INTERNAL ERROR HAS OCCURRED. STATUS
                          COMMAND NOT AVAILABLE. (SNACIERR 86)

             CAUSE        An internal error has occurred.  The SNACONTROL
                          STATUS command cannot be executed at this time.

             ACTION       A memory dump will probably be required.  Call
                          your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 87  MESSAGE      ATTEMPT TO DISPLAY LINK STATUS FAILED. (SNACIERR
                          87)

             CAUSE        An attempt to call the link status display
                          procedure failed.

             ACTION       Use the MPE FLIST command to ensure that the
                          file XL.PUB.SYS exists.  Write down the
                          circumstances and call your Hewlett-Packard
                          support contact.

--------------------------------------------------------------------------

SNACIERR 88  MESSAGE      CANNOT AUTODIAL BECAUSE OF CABLING PROBLEMS.
                          (SNACIERR 88)

             CAUSE        No cable is attached, a non-automatic-dial cable
                          is attached, or a bad automatic-dial cable is
                          attached.

             ACTION       Ensure that the cable is properly attached.  If
                          it is, try attaching a different cable.  If the
                          error still occurs, write down the circumstances
                          and call your Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 89  MESSAGE      LOCAL AUTODIAL MODEM IS BUSY. (SNACIERR 89)

             CAUSE        Someone else is using the local automatic-dial
                          modem.

             ACTION       Check with other users on the system to ensure
                          that no one else is using the modem.  If no one
                          is using the modem, powercycle the modem and try
                          again.  If someone is using the modem, wait
                          until they are not using it and then try again.

--------------------------------------------------------------------------

SNACIERR 90  MESSAGE      LOCAL AUTODIAL MODEM IS NOT POWERED ON.
                          (SNACIERR 90)

             CAUSE        The local automatic-dial modem is not turned on.

             ACTION       Turn the modem on.

--------------------------------------------------------------------------

SNACIERR 91  MESSAGE      AUTODIAL NOT COMPLETED. (SNACIERR 91)

             CAUSE        The automatic dial was not completed, possibly
                          because the remote system's modem is not turned
                          on or is not functional.

             ACTION       Ensure that the remote system's modems are
                          turned on and functional.

--------------------------------------------------------------------------

SNACIERR 92  MESSAGE      AUTODIAL PHONE NUMBER CONFIGURED INCORRECTLY.
                          (SNACIERR 92)

             CAUSE        The configured automatic-dial phone number is
                          not correct.

             ACTION       Use NMMGR or the configuration file critical
                          summary to ensure that the Phone Number field
                          contains the correct number.

--------------------------------------------------------------------------

SNACIERR 93  MESSAGE      AUTODIAL NOT ATTEMPTED BECAUSE NODE IS SHUTTING
                          DOWN. (SNACIERR 93)

             CAUSE        The automatic dial was not attempted because the
                          node is in the process of shutting down.

             ACTION       Issue the SNACONTROL START command to restart
                          the node, and then try the automatic dial again.

--------------------------------------------------------------------------

SNACIERR 94  MESSAGE      BAD AUTODIAL REPLY. (SNACIERR 94)

             CAUSE        An internal error has occurred.

             ACTION       Write down the circumstances and call your
                          Hewlett-Packard support contact.

--------------------------------------------------------------------------

SNACIERR 95  MESSAGE      AUTODIAL REQUEST IS ALREADY PENDING. (SNACIERR
                          95)

             CAUSE        Another process has already issued an automatic
                          dial request.

             ACTION       The node will become active after the other
                          automatic dial request is successful; no action
                          is needed.

--------------------------------------------------------------------------

SNACIERR 104 MESSAGE      NMCONFIG.PUB.SYS LUDATA CONFIGURATION ERROR. RUN
                          NMMGR CONDENSE AND VALIDATION ROUTINE. (SNACIERR
                          104)

             CAUSE        SNANODE data configuration error.  Mostly due to
                          LU configuration (duplicate NAU, duplicate
                          LUNAME, PU type not matching LU configuration).

             ACTION       Check NMCONFIG.PUB.SYS and run validate routine.

--------------------------------------------------------------------------

SNACIERR 105 MESSAGE      CAN'T SPECIFY LFSID HERE. (SNACIERR 105)

             CAUSE        LFSID was specified as a parameter to an
                          SNACONTROL command other than SNACONTROL STATUS.
                          Only SNACONTROL STATUS permits this parameter.

             ACTION       Don't specify LFSID as a parameter to any
                          SNACONTROL command except SNACONTROL STATUS.

--------------------------------------------------------------------------

SNACIERR 106 MESSAGE      CAN'T SPECIFY NAU HERE. (SNACIERR 106)

             CAUSE        NAU was specified as a parameter to an
                          SNACONTROL command other than SNACONTROL STATUS.
                          Only SNACONTROL STATUS permits this parameter.

             ACTION       Don't specify NAU as a parameter to any
                          SNACONTROL command except SNACONTROL STATUS.

--------------------------------------------------------------------------

SNACIERR 107 MESSAGE      CAN'T SPECIFY STATE HERE. (SNACIERR 107)

             CAUSE        STATE was specified as a parameter to an
                          SNACONTROL command other SNACONTROL STATUS. Only
                          SNACONTROL STATUS permits this parameter.

             ACTION       Don't specify STATE as a parameter to any
                          SNACONTROL command except SNACONTROL STATUS.

--------------------------------------------------------------------------

SNACIERR 108 MESSAGE      CAN'T SPECIFY SESSTYPE HERE. (SNACIERR 108)

             CAUSE        SESSTYPE was specified as a parameter to an
                          SNACONTROL command other than SNACONTROL STATUS.
                          Only SNACONTROL STATUS permits this parameter.

             ACTION       Don't specify SESSTYPE as a parameter to any
                          SNACONTROL command except SNACONTROL STATUS.

--------------------------------------------------------------------------

SNACIERR 109 MESSAGE      BAD NAU SPECIFICATION. (SNACIERR 109)

             CAUSE        A non-integer value was specified in the NAU=
                          parameter.

             ACTION       The NAU= parameter must be an integer.

--------------------------------------------------------------------------

SNACIERR 110 MESSAGE      BAD LFSID SPECIFICATION. (SNACIERR 110)

             CAUSE        A non-hex value was specified in the LFSID=
                          parameter.

             ACTION       The LFSID= parameter must be a hex value.

--------------------------------------------------------------------------

SNACIERR 111 MESSAGE      NAU NOT FOUND. (SNACIERR 111)

             CAUSE        The NAU specified in the SNACONTROL STATUS
                          command does not exist.

             ACTION       The NAU= parameter must specify an existing NAU.

--------------------------------------------------------------------------

SNACIERR 112 MESSAGE      LFSID NOT FOUND. (SNACIERR 112)

             CAUSE        The LFSID specified in the SNACONTROL STATUS
                          command does not exist.

             ACTION       The LFSID= parameter must specify an existing
                          LFSID.

--------------------------------------------------------------------------

SNACIERR 113 MESSAGE      BAD LUNAME SPECIFICATION. (SNACIERR 113)

             CAUSE        A bad LUNAME was specified in the LUNAME=
                          parameter.

             ACTION       Verify that the LUNAME= parameter was valid.

--------------------------------------------------------------------------

SNACIERR 114 MESSAGE      NO SUCH SESSIONS FOUND. (SNACIERR 114)

             CAUSE        No sessions were found that match the given
                          STATE= and SESSTYPE= parameters.

             ACTION       None.  This is a normal event.

--------------------------------------------------------------------------

SNACIERR 115 MESSAGE      BAD TOKEN RING LINK NAME. (SNACIERR 115)

             CAUSE        Link name specified in the SNA NODE
                          configuration is not valid.

             ACTION       Change LINKNAME to a valid link name.

--------------------------------------------------------------------------

SNACIERR 116 MESSAGE      SNA TOKEN RING NOT INSTALLED PROPERLY. (SNACIERR
                          116)

             CAUSE        SNA TOKEN RING not installed.

             ACTION       Call your Hewlett-Packard contact.

--------------------------------------------------------------------------

SNACIERR 117 MESSAGE      SNA SDLC NOT INSTALLED PROPERLY. (SNACIERR 117)

             CAUSE        SNA SDLC LINK not installed.

             ACTION       Call your Hewlett-Packard contact.

--------------------------------------------------------------------------



MPE/iX 5.0 Documentation