NM and CM callable.
Formats the time of day, in the specified language, obtained with the
CLOCK intrinsic.
Syntax
I32V CA I16V U16A
NLFMTCLOCK (time, buffer, langnum, error);
Parameters
- time
32-bit signed integer by value (required)
Contains the time format returned by the CLOCK intrinsic:
Bits | Value/Meaning |
24:8 | Tenths of seconds |
16:8 | Seconds |
8:8 | Minute of hour |
0:8 | Hour of day |
- buffer
character array (required)
Returns the formatted time of day in an 8-character array. Using a buffer
of a different size may produce unexpected results.
- langnum
16-bit signed integer by value (required)
Contains the language ID number, specifying which format to use. A
langnum of 0 returns the time formatted as if you used
FMTCLOCK.
- error
16-bit unsigned integer array (required)
Returns two elements: the first element is the error number; the second
element is reserved and always returns 0. The possible error number
values are:
Value | Meaning |
0 | Successful |
1 | *NLS not installed |
2 | *Specified language not configured |
3 | Invalid time format |
4 | *NLS internal error |
5 | *NLS internal error |
6 | *NLS internal error |
* Does not apply to calls with a langnum equal to 0
(NATIVE3000/XL).