  - 1
 
  
    - MESSAGE
 
    Inexact exception in a floating point conversion.
        (HPFPCONVERT WARNING 1)  
    - CAUSE
 
    Exact representation is not possible in the specified
        IEEE destination format.  
    - ACTION
 
    None.  
    
 
  - 3
 
  
    - MESSAGE
 
    Underflow exception in a floating point conversion.
        (HPFPCONVERT WARNING 3)  
    - CAUSE
 
    Result magnitude is too small for the destination format.  
    - ACTION
 
    Consider other destination formats and/or rounding mode.  
    
 
  - 5
 
  
    - MESSAGE
 
    Overflow result in a floating point conversion.
        (HPFPCONVERT WARNING 5)  
    - CAUSE
 
    Result magnitude is too large for the destination format.  
    - ACTION
 
    Consider other destination formats and/or rounding mode.  
    
 
  - 8
 
  
    - MESSAGE
 
    Invalid operation exception.
        (HPFPCONVERT WARNING 8)  
    - CAUSE
 
    The input NaN cannot be represented in the
        destination format.  
    - ACTION
 
    Program around the attempted conversion or correct
        the bad data.  
    
 
  - 101
 
  
    - MESSAGE
 
    Invalid source format. (HPFPCONVERT ERROR 101)  
    - CAUSE
 
    The source format value is not between 1 and 5.  
    - ACTION
 
    Use valid numbers (shortint 1 through 5): 1 = cm32,
        2 = cm64, 3 = nm32, 4 = nm64, 5 = nm128  
    
 
  - 102
 
  
    - MESSAGE
 
    Invalid destination format. (HPFPCONVERT ERROR 102)  
    - CAUSE
 
    The destination format value is not between 1 and 5.  
    - ACTION
 
    Use valid numbers (shortint 1 through 5): 1 = cm32,
        2 = cm64, 3 = nm32, 4 = nm64, 5 = nm128  
    
 
  - 104
 
  
    - MESSAGE
 
    Invalid rounding mode. (HPFPCONVERT ERROR 104)  
    - CAUSE
 
    The rounding mode value is not between 0 and 3.  
    - ACTION
 
    Use valid numbers: 0 = round to nearest, 1 = round toward zero,
        2 = round toward + infinity, 3 = round toward - infinity  
    
 
  - 105
 
  
    - MESSAGE
 
    CM to NM switch error. (HPFPCONVERT ERROR 105)  
    - CAUSE
 
    Input parameters are incomplete or invalid.  
    - ACTION
 
    Use valid input parameters.  
    
 
  - 106
 
  
    - MESSAGE
 
    CM parameter(s) missing. (HPFPCONVERT ERROR 106)  
    - CAUSE
 
    Parameters incomplete or invalid.  
    - ACTION
 
    Use all valid required parameters.  
    
 
    
    
     
    
    
      
        
  File System Storage Management (Subsystem 185) | 
       | 
      
        
  High Level I/O (Subsystem 111) | 
     
     
     
   |