The following message will automatically be displayed on the
operator's console when a network transport tries to startup
the WAN driver: WAN MODULE CONFIG (linkname) Version: A0001037 This section describes error messages that might occur when
you are starting a LAP-B link. They are displayed on the HP 3000
Series 900 operator's console in the following format: WAN MODULE CONFIG (linkname) Message text WAN MODULE CONFIG (linkname) Error ErrorNum, Status = Status, Path: PhysPath MESSAGE: The link
type is not SDLC, LAP-B, or RJE. | CAUSE: The caller
of this module did not set the link type to one of SDLC, LAP-B,
or RJE. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
open NMCONFIG.PUB.SYS. | CAUSE: Either
the NMCONFIG.PUB.SYS
file was purged or renamed, or the file NMCONFIG.PUB.SYS
was opened with exclusive access. ACTION: Restore the file
NMCONFIG.PUB.SYS
from a backup tape, or wait for the program or process that has
this file opened exclusively to close it. |
MESSAGE: Link data
not found in NMCONFIG.PUB.SYS. | CAUSE: The link
data in the file NMCONFIG.PUB.SYS
does not exist. ACTION: Using the program
NMMGR.PUB.SYS,
create the link data associated with the link you are trying to
start up. |
MESSAGE: Could not
close NMCONFIG.PUB.SYS. | CAUSE: The file
NMCONFIG.PUB.SYS,
which contains configuration information could not be closed. This
did not prevent the link from starting, but it is worth noting because
this should not happen. The file system integrity may be in question. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
open download file. | CAUSE: Either
the file PSILAPB0.PUB.SYS
was purged or renamed, or the file was opened for exclusive access. ACTION: Either restore the
PSILAPB0.PUB.SYS
file from a backup tape, or wait for the program or process that
has this file opened exclusively to close it. |
MESSAGE: FGETINFO
failed to return recsize and/or numrec. | CAUSE: The file
PSILAPB0.PUB.SYS
is corrupted. ACTION: Restore the file
from a backup tape. |
MESSAGE: FREEZE of
download file failed. | CAUSE: The system
is experiencing memory shortage problems. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
open trace file ! | CAUSE: Either
the trace file name specified is invalid, or the trace file specified
was opened for exclusive access. ACTION: Either wait for the
program or process that has the trace file opened exclusively to
close the file, or specify a different file name or let it default
to NMTCxxxx.PUB.SYS (xxxx =
next available 4 digit number). |
MESSAGE: Could not
start trace. | CAUSE: There are
many causes and the only way to determine them is by the status
indicator. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. In the meantime, try running without trace. |
MESSAGE: Could not
start trace. | CAUSE: Trace may
have been turned off via the LINKCONTROL
command, but the link software status indicated that it was on. ACTION: Ignore this problem
unless you are experiencing other problems. Otherwise record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
freeze the driver configuration data. | CAUSE: The system
is experiencing memory shortage problems. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
send the configuration message. | CAUSE: Internal
system ports problem. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
receive the config reply message. | CAUSE: Internal
system ports problem. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Timeout
waiting for the config reply message. | CAUSE: Could not
configure the link software or the card. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Received
message was not the config reply. | CAUSE: An erroneous
message was left hanging on the process port data communications
subqueue. ACTION: Try to start the
link again. If this problem continues then record the error information
printed on the console and contact your Hewlett-Packard representative. |
MESSAGE: Link configuration
data is invalid. | CAUSE: The configuration
information was corrupted. ACTION: Run NMMGR.PUB.SYS
and recreate the link data associated with this node. If this does
not work then record the error information printed on the console
and contact your Hewlett-Packard representative. |
MESSAGE: Could not
unfreeze the configuration data. | CAUSE: The system
is experiencing memory problems. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Unable to
obtain dump/diag ports. | CAUSE: The Sherlock
diagnostic software and/or Network Dump Process was not installed
properly. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
create the auxiliary buffer pool. | CAUSE: The buffer
size specified is either too small (under 16 bytes) or is too large
(over 4096 bytes). ACTION: Adhere to the range
allowed by NMMGR when configuring the buffer size. If this does
not fix this problem then record the error information printed on
the console and contact your Hewlett-Packard representative. |
MESSAGE: Could not
create or bind with the driver. | CAUSE: Possible
causes for this problem are as follows: (Status = FAxx00D9)
The I/O subsystem still has the card configured and marked active. (Status = E0xx00D5)
The Bus converter is not configured. (Status = DAxx00D5)
There is no card in the slot for the path number given. (Status = CDxx00D5)
The card is bad for the path number given. (Status = C3xx00D9)
The wrong card exists for the path number given.
ACTION: Possible actions
for this problem are as follows: Try
shutting down the link first. The system may need to be restarted.
If this does not work then record the error information printed
on the console and contact your Hewlett-Packard representative. Check the bus converter configuration in SYSGEN.
You may need to configure the bus converter using SYSGEN (Series
950 only). Set the correct physical path number in NMCONFIG.PUB.SYS
for this link or contact your Hewlett-Packard representative to
install a PSI card. Verify that the physical path configured for the
link matches with a good PSI card. Run Sherlock
Diagnostics to determine if the PSI card is good. Contact your Hewlett-Packard
representative if you need to install a good PSI card. Set the correct physical path number in NMCONFIG.PUB.SYS
for this link.
|
MESSAGE: Could not
add the link name to the link table. | CAUSE: Possible
causes for this problem are as follows: Another
the link with the same name has already started. The link table was corrupted. The link table does not exist.
ACTION: Possible actions
for this problem are as follows: Try
shutting down the link and starting it up again. Please record the error information printed on the
console and contact your Hewlett-Packard representative. The system may need to be restarted.
|
MESSAGE: Could not
unfreeze the download file ! | CAUSE: The system
is experiencing memory problems. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Could not
close download file ! | CAUSE: The system
is experiencing file system problems. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: Manager
entry not found in the system library. | CAUSE: The link
software was not installed properly. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
MESSAGE: The link
has already been started. | CAUSE: A link
of the same name is currently active. You cannot start the same
link twice. ACTION: Please record the
error information printed on the console and contact your Hewlett-Packard
representative. |
|