The following error messages may appear when using or installing
FDDI on your system. The following
list consists of error messages that you may be able to resolve
yourself. Other error messages may appear, but require the help
of your HP representative. If the message number does not appear
in this list, either write down the error if it is displayed on
your console, take a system dump, or run the diagnostics before
calling your HP representative for help. MESSAGE: FDDI link
! aborted user's request. | CAUSE: Your request
has been aborted due to power fail recovery or the driver was shutting
down. ACTION: This is a warning. |
MESSAGE: FDDI link
! received frame with unknown 802.2 ctrl option. | CAUSE: Unknown. ACTION: This is only a warning. |
MESSAGE: FDDI link
! received frame with unknown 802.2 ctrl option. | CAUSE: Unknown. ACTION: This is only a warning. |
MESSAGE: FDDI link
! trace manager overrun. | CAUSE: The driver
is generating trace entries faster than the trace manager can process
them. This causes some trace entries to be lost. ACTION: This is only a warning
and is indicative of a very busy system. If debugging is a problem
use partial tracing if possible (when full data frames are not needed)
to ensure trace data is not lost. |
MESSAGE: FDDI link
! aborted user's request. | CAUSE: Your request
has been aborted due to the power fail recovery or the driver was
shutting down. ACTION: This is a warning. |
MESSAGE: FDDI link
! hardware reported that the ring went down. | CAUSE: Unknown. ACTION: This is a warning.
If the ring does not come up shortly, then check network components
(adapters, cables, etc.). Have your network provider examine the
network. |
MESSAGE: FDDI link
! found incorrect HW or SW ID. | CAUSE: The FDDI
driver found an old or incorrect version of the firmware or hardware
on the FDDI interface card. ACTION: Update the card to
the correct version. |
MESSAGE: FDDI link
! could not read hardware ID. | CAUSE: The FDDI
driver could not read the FDDI hardware identification codes. ACTION: Run the diagnostic
program to see if the hardware has failed. If so, replace the card. |
MESSAGE: Could not
open NMCONFIG file for link ! | CAUSE: The file
NMCONFIG.PUB.SYS does not exist
or is not readable. ACTION: Create NMCONFIG.PUB.SYS
with NMMGR. |
MESSAGE: Could not
read NMCONFIG file for link ! | CAUSE: The file
NMCONFIG.PUB.SYS either did not
exist or was not readable. ACTION: Use NMMGR to create
a NMCONFIG file. Check that its
file protections are correct. |
MESSAGE: NMCONFIG
file link ! not validated. | CAUSE: NMCONFIG.PUB.SYS was
not validated after being updated. ACTION: Use NMMGR to validate
NMCONFIG.PUB.SYS. |
MESSAGE: Invalid
card at path specified for link ! | CAUSE: The card,
as the configured path, is not an FDDI
card. ACTION: Change your configuration
in NMCONFIG.PUB.SYS to the correct
path. |
MESSAGE: No card
at path specified for link ! | CAUSE: The FDDI
subsystem could not find a card at the configured path. ACTION: Change your configuration
in NMCONFIG.PUB.SYS to the correct
path. |
MESSAGE: FDDI driver
already created. | CAUSE: The driver
was already created under a different linkname, or by the diagnostic. ACTION: Check your NMCONFIG.PUB.SYS
file and correct it if needed, or check to see if the diagnostic
is running. |
|