RPM errors are (32-bit) integers that are returned in the
result parameter of the intrinsics RPMCREATE,
RPMKILL, RPMCONTROL,
and RPMGETSTRING when the intrinsic
execution fails. (A result of 0 indicates that the intrinsic succeeded.)
There are two ranges of RPM errors returned by the HP 3000 implementation
of RPM. The first range (0-99) includes generic RPM errors.
The second range (100-199) includes errors specific to
the HP 3000 implementation. MESSAGE: NO ERROR. | CAUSE: Successful
execution. ACTION: None. |
MESSAGE: NETWORK
DOWN. | CAUSE: The transport
is not available for use by RPM. ACTION: Wait until the transport
is available. |
MESSAGE: ILLEGAL
PROGRAM NAME LENGTH. | CAUSE: The program
namelen parameter in an RPMCREATE
call is greater than the allowed maximum of 256 (characters). ACTION: Shorten the program
name. |
MESSAGE: ILLEGAL
FLAG. | CAUSE: An RPMCREATE
call includes a flags parameter with one or more undefined flag
bits set. ACTION: Correct the flags
parameter. The defined flags are: - bit 0
No dsline (3000-specific) - bit 1
Wait until son dies (3000-specific) - bit 31
Dependent
|
MESSAGE: ILLEGAL
OPTION. | CAUSE: An RPMCREATE
call includes an opt parameter with one or more invalid options. ACTION: Correct the opt
parameter. The valid options are: - 20000
RPM string - 22001-22012, 22100
MPE options
|
MESSAGE: ILLEGAL
OPTION FORMAT. | CAUSE: The opt
parameter in an RPMCREATE
call is not formatted correctly. ACTION: Correct the opt format;
use the INITOPT
and ADDOPT intrinsics
to format the opt array. |
MESSAGE: INVALID
LOGIN. | CAUSE: This may
be caused by several conditions relating to the login (Env) and
password parameters of RPMCREATE: The login
parameter is syntactically incorrect for the remote machine. For
the HP 3000, the logon syntax is: user[/userpass].acct[/acctpass],group[grouppass] The password parameter is syntactically incorrect
for the remote machine. For the HP 3000, the password syntax is: [userpass][acctpass][,grouppass] The login and password are syntactically correct,
but the login (on the HP 3000, user,
group, or account)
is not defined on the remote machine. The login and password parameters do not supply
required passwords for the login. The login and password parameters were correct,
but the logon failed for some reason (on the HP 3000: jobfence too
high, session limit exceeded).
ACTION: Correct the login
and password parameters, if necessary. If login and password are
correct, determine the reason for the remote logon failure: possibly
wait until the remote logon resources are available. |
MESSAGE: ILLEGAL
PROGRAM NAME. | CAUSE: The program
indicated by the progname (and
namelen) parameters of an RPMCREATE
was not found on the remote computer. ACTION: Correct the progname
(and namelen) parameters, if necessary.
Make sure the program file exists on the remote node. Note that,
if the program name is not fully qualified, the logon group and
account (determined by login) will be used. |
MESSAGE: INVALID
PROGRAM DESCRIPTOR. | CAUSE: The program
descriptor (pd)
parameter of an RPMKILL contained
a program descriptor that was not defined on the remote node. There
are two cases in which this can happen: The
(pd) value was not generated by
PRM on the remote node. This would happen if the program descriptor
were incorrect or corrupted, or if the RPMCREATE
that was supposed to return the descriptor failed. The (pd)
value was generated for a program on the remote node, but the program
terminated itself, or was terminated by an abort or an RPMKILL.
In this case the program's descriptor is deleted when the
program terminates, and a later RPMKILL
receives the Invalid Program Descriptor error.
ACTION: Depending on the
cause: Correct the program descriptor.
Do not issue an RPMKILL when the
RPMCREATE failed. Do not issue an RPMKILL
if the created process is supposed to terminate itself. Do not issue
more than one RPMKILL for the same
process.
|
MESSAGE: REMOTE PROCESS
LIMIT. | CAUSE: A resource
needed to create the process is not available. On a remote HP 3000
(or the local HP 3000 if the created process is local), this can
include: Process Control Block entry
for created process stack space for created process RPM Table entry for created process pseudo terminal for created session On the local HP 3000, some resources needed for a process
creating a dependent process may not be available: RPM Table entry for creator process AFT entry in creator process' stack
ACTION: Wait for the resource(s)
to become available. If the Remote Process Limit error occurs often,
resources like the number of PCB and DST entries or number of configured
pseudo terminals may have to be increased. |
MESSAGE: REMOTE MEMEORY
LIMIT. | CAUSE: Memory
was not available for storage of data. The possible reasons for
this include: RPM String could not
be stored buffers in the RPM server could not be allocated
ACTION: Wait until the resource(s)
become available. |
MESSAGE: PROGRAM
ACCESS ERROR. | CAUSE: The program
to be created by an RPMCREATE could
not be accessed. This may be due to one of the following reasons: The program file is secured against access from
the login user and account. The program file has a lockword that was not specified
in progname. The program name in progname is not syntactically
correct
ACTION: Depending on the
cause: Change the program file's
security or the login user and account to allow Execute access to
the program. Insert the program file's lockword into
the progname parameter. The syntax is: progname/lockword[.acct][,group]] Correct the syntax of the progname
|
MESSAGE: UNKNOWN
ERROR. | CAUSE: Internal
software error. For example, the RPM Table (which is always supposed
to be there) was not found. ACTION: See Appendix A “Submitting an SR ” of this manual. |
MESSAGE: NETWORK
ERROR. | CAUSE: An error
occurred in using a transport connection to send or receive an RPM
message. The transport error will be logged by Network Management
logging, log class 6, subclass 5. ACTION: Examine the log file
and see Appendix A “Submitting an SR ” of
this manual. |
MESSAGE: INCOMPATIBLE
VERSIONS. | CAUSE: The versions
of the RPM software on the local and remote computers are incompatible. ACTION: Check the versions
of the RPM software on the local and remote computers. On an HP
3000, the RPM version can be obtained by running NMMAINT.PUB.SYS,
or by NSCONTROL VERSION=MOD.
The RPM version is listed as ASRPMVERS.
Update the software on the local or remote nodes to compatible versions. |
MESSAGE: UNSUPPORTED
OPTION. | CAUSE: A legal
option specified in the opt parameter of the RPMCREATE
is not supported by the remote RPM software. ACTION: Modify the option,
or update the remote RPM software to a version that supports the
option. |
MESSAGE: RPMCREATE
LENGTH ERROR. | CAUSE: An RPMCREATE
resulted in a message that could not be handled by the remote node
RPM software. ACTION: Decrease the size
of the RPMCREATE message by shortening
the program name or the lengths of options. |
MESSAGE: ILLEGAL
OPTION ERROR. | CAUSE: The value
of an option in the opt parameter of an RPMCREATE
was invalid. ACTION: Check the options
for validity. In some cases (like the Initial Stack Size option),
the option value might exceed maximum configured limits for the
remote system. |
MESSAGE: INVALID
NODE NAME. | CAUSE: The node
name specified by the location and loclen
parameters of an RPMCREATE call
is not a valid node. It may be syntactically incorrect, or it may
not be defined in the network. ACTION: Correct the location
and loclen parameters. |
MESSAGE: NO RPM STRING. | CAUSE: A program
called the RPMGETSTRING intrinsic,
but there was no RPM string to be passed to the program. This could
be caused by one of the following: The
program was not created by an RPMCREATE
(but by a RUN, CREATE, or
CREATEPROCESS). The creating process did not pass an RPM string
in the opt parameter in its RPMCREATE
call. The created process has called RPMGETSTRING
more times than the number of RPM strings passed by the creating
process.
ACTION: Either add the RPM
string to the creating process's RPMCREATE
call, or remove the RPMGETSTRING
from the created program. |
MESSAGE: RPM STRING
LENGTH. | CAUSE: In a call
to RPMGETSTRING, the parameter
specifying the maximum string length was less than zero. ACTION: Check that the parameter
specifying string length is set to a positive integer in the RPMGETSTRING
intrinsic. If the string length is positive, and you are getting
the error anyway, submit an SR. See Appendix A “Submitting an SR ” in this manual. |
MESSAGE: REMOTE SON
ABORTED. | CAUSE: The remote
process aborted abnormally. ACTION: Check the remote
program to ascertain what caused the premature termination. |
MESSAGE: INSUFFICIENT
STACK SPACE. | CAUSE: The program
calling RPMCREATED, RPMKILL,
RPMCONTROL, or RPMGETSTRING
could not expand its stack to accommodate the requirements of the
RPM software. ACTION: Increase the stack
size and/or maxdata of the program and rerun. |
MESSAGE: NOT AT THE
STACK. | CAUSE: RPMCREATE,
RPMKILL, or RPMGETSTRING
was called when the DB register was not at the process'
stack "split-stack mode". ACTION: Switch the DB register
to the process stack before calling any RPM intrinsic. |
MESSAGE: PARAMETER
OUT OF BOUNDS. | CAUSE: A parameter
for an RPMCREATE, RPMKILL,
RPMCONTROL, or RPMGETSTRING
call was not fully within the stack of the calling process. ACTION: Check each parameter
of the call to make sure it is between the DL and S registers. For
arrays, also check that the end of the array (beginning + length)
is also between DS and S. |
MESSAGE: PROGRAM
DOES NOT HAVE PH CAPABILITY. | CAUSE: A program
without PH (Process Handling) capability called RPMCREATE
or RPMKILL. ACTION: PREP
the program with CAP=PH... and rerun. (Only users with PH capability
can PREP a program with CAP=PH.) |
MESSAGE: REQUIRED
PARAMETER OMITTED. | CAUSE: A required
parameter for RPMCREATE or RPMKILL
has been omitted. The required parameters are: - RPMCREATE
progname, namelen - RPMKILL
pd
ACTION: Add the required
parameter to the call. |
MESSAGE: RPM OR PTOP
PROCESS AT LOCATION. | CAUSE: An RPM
or PTOP created process already
exists in the remote session specified by the location parameter.
Because of the design of the RPM
and PTOP services, only one RPM
or PTOP process can exist in a
remote session. ACTION: Terminate the first
RPM or PTOP
process, or change the location to a different remote session. By
means of the environment facility of Network Services, it is possible
to have more than one remote session on the same remote node. Use
DSLINE commands to set up the environments; for
example: DSLINE S1=NODE DSLINE S2=NODE Then use the different environment IDs (S1 and S2) in the
location parameter of the RPMCREATEs
and of a POPEN. |
MESSAGE: LOGON TIME
OUT. | CAUSE: The logon
of the remote session for an RPMCREATE
did not complete in a set amount of time. This time can be set by
the Logon TimeOut option in an RPMCREATE;
if the logon TimeOut is not set, a default of 1 hours (3600.0 seconds)
is used. ACTION: Increase the timeout
with the Logon TimeOut option; the timeout depends on factors like
the load on the remote system and set-up and execution time of UDCs
for the remote session. It is possible to have a logon UDC that
never completes (for example, one that runs a program that does
not terminate), so in this case no logon timeout is sufficient. |
MESSAGE: LOCAL RPM
SERVICE NOT STARTED. | CAUSE: The local
RPM service (RPML) has not been started, or has been stopped and
aborted. ACTION: Start the RPM service
with NSCONTROL START=RPML or NSCONTROL START.
(Only users with NM capability can use the NSCONTROL
command. |
MESSAGE: RPMDAD CREATE
ERROR. | CAUSE: The remote
node was unable to create the RPMDAD
process. ACTION: Check to verify that
RPMDAT.PUB.SYS exists on the remote
node. Also check that the process limit has not been exceeded on
the remote node. The log file (NMLGxxxx.PUB.SYS)
may contain additional information. |
MESSAGE: RPMDAD DEAD
ERROR. | CAUSE: RPMDAD
is terminating and exiting the session because the session has been
aborted or because all sons created by RPM have terminated. ACTION: Try again. A new
RPMDAD and a new session are created
at the next RPMCREATE request. |
MESSAGE: BAD RPMCONTROL
STATE. | CAUSE: RPMCONTROL
was unable to suspend the remote process. A system process may have
impeded the remote process, or the remote process may be waiting
for a system resource. ACTION: Call RPMCONTROL
again with the suspend option, or attempt to use another method
of synchronization such as NetIPC. |
MESSAGE: SWITCH FAILURE. | CAUSE: RPM was
unable to call a native mode procedure. ACTION: See Appendix A “Submitting an SR ” in this manual.
The log file (NMLGxxxx.PUB.SYS)
may contain additional information. |
MESSAGE: ADOPT FAILURE. | CAUSE: RPMDAD
was unable to enter the remote session because the remote session
was being aborted. ACTION: Try again. Make sure
the session is not aborted before the RPM son is created. The log
file (NMLGxxxx.PUB.SYS)
may contain additional information. |
|