Sets the next value of a specified resource counter, and optionally
enables automatic rollback when a specified limit is reached. Duplicate
values are avoided.
Operation Notes |
 |
The SETCOUNTER
command allows you to specify limits other than 1 and the maximum
possible value of one of four counters (but within that range) You
may set limits for one counter with each use of the command and,
therefore, you must invoke the command four times to change the
limits of all four coutners.
You may also use SETCOUNTER
to display the current values of the counters. Only one invocation
of the command is necessary to see all current values.
To set a maximum operating value for the specified counter
and enable its operation, enter a positive value for the MAX
keyword. Specify MAX=0
to disable the operation, that is, the counter's limit is then its
maximum possible value. Omitting MAX
leaves its previous value in force. Once MAX
is reached, the next value tried is the BASE
value. If you specify a non-zero value for MAX,
it must be greater than the current BASE
for the corresponding counter, but less than the maximum possible
value
The BASE
keyword causes the specified counter to be immediately yanked to
the specified value. If you supply a value, it must be less than
the supplied or current value of MAX
(other than 0), and in any case, less than the maximum possible
value. If you do not specify BASE,
it is not changed, nor is current sequencing affected.
For each counter, duplicate values are avoided. For example,
if #O10 is in use when due to be assigned as the next output spoolid,
it is skipped and #O11 is tried. This process continues until an
available value is found.
The defaults, established when the system is booted, are MAX=0
and BASE=1. This
is for backward compatibility; if these settings are not changed,
the system will operate as it does today. These boot time settings
can be modified by including one or more instances of this command
in SYSSTART.PUB.SYS.
The SHOW
option can be used alone to display the current values of BASE
and MAX for a
specified counter or for all four counters. If used in addition
to either BASE
or MAX, the value(s)
displayed are the new setting(s).
This command may be issued from a session, job, program, or
in Break. Any display specified by the SHOW option is breakable,
but command operation is not. Any user may execute this command
with only the SHOW option to display current values of BASE, Next,
and MAX for the specified counter (or all counters if none is specified).
When changing either value, this command may be executed only:
by a user with SM capability, -OR-
by any user who has been allowed the use of the
SETCOUNTER command with the ALLOW command.
Examples |
 |
To display the current BASE, Next, MAX, and maximum possible
values for all four counters, enter:
:SETCOUNTER ; SHOW Absolute COUNTER BASE Next MAX maximum Input spoolid 1 172 16383 9999999 Output spoolid 1 1872 32767 9999999 Job number 1 172 0 16383 Session number 1 2753 0 16383
|
To limit input spoolids to the same range as their corresponding
jobs, enter:
:SETCOUNTER INSP; MAX=16383
|