 |  |  |  |  | NOTE: KSAM error messages are included with subsystem 143
(File System) messages. Refer to chapter 4, File System
(Native Mode),
for listing of messages. |  |  |  |  |
- 1026
- MESSAGE
Type manager; an internal error occurred.
- CAUSE
You requested a lower level system service and this reported an error to the type manager.
- ACTION
If the problem persists, contact your Hewlett-Packard support engineer.
- 1079
- MESSAGE
TM_KSM_INVALID_OFFSET
- CAUSE
The file offset pointer calculated for the KSAM file is invalid.
- ACTION
Close the KSAM file, store it to tape, and call your Hewlett-Packard
support representative.
- 1080
- MESSAGE
TM_KSM_UNEXPECTED_ERROR
- CAUSE
During an operation on a KSAM file, a non-file system error occurred.
- ACTION
Close the KSAM file, store it to tape, and call your
Hewlett-Packard support representative.
- 6005
- MESSAGE
Type manager; invalid function code or parameter.
- CAUSE
An FCONTROL or FDEVICECONTROL function, or one of its parameters, is not valid
for the particular device or access method in which it was used. It may also
be invalid for any device (for example, out of range).
- ACTION
Check the intrinsic call for which the error is reported and correct any
errors in the calling sequence.
- 6006
- MESSAGE
Type manager; you specified a parameter value that is more than the maximum specified for this
function.
- CAUSE
Self-explanatory.
- ACTION
Use the MPE XL Intrinsics manual to verify the set of acceptable parameters
for a given function code.
- 6007
- MESSAGE
Type manager; you specified a parameter value that is less than the minimum specified for this
function.
- CAUSE
Self-explanatory.
- ACTION
Use the MPE XL Intrinsics manual to verify the set of acceptable parameters
for a given function code.
- 6013
- MESSAGE
Type manager; device is off-line.
- CAUSE
For printers attached via the Distributed Terminal Controller (DTC), this is a
generic error indicating the inability of the DTC to communicate with its
device. It is currently not returned for other devices.
- ACTION
Check the DTC-to-device cable connections, parity and baud rate settings, DTR
and CTS settings, and Transmit/Receive Pacing settings. Ensure that they are
set as required for proper use by the DTC.
- 6022
- MESSAGE
Type manager; unit failure.
- CAUSE
An undetermined device or transmission error occurred.
- ACTION
Check lower level statuses to determine the root cause of the error.
- 6025
- MESSAGE
Type manager; timeout while waiting for I/O completion.
- CAUSE
This usually indicates a hardware failure of some component of the I/O
subsystem.
- ACTION
Contact your Hewlett-Packard support engineer.
- 6026
- MESSAGE
Type manager; data transmission error.
- CAUSE
An undetermined transmission error was reported by a lower level subsystem.
- ACTION
Check the lower level statuses to determine the root cause of the error.
- 6029
- MESSAGE
Type manager; the device reported a power-up.
- CAUSE
Self-explanatory. For printers, this status is returned only if device status
reporting is disable (the default). If it is enabled, the intrinsic interface
returns CCG instead, indicating that status is available.
- ACTION
The application or operator should take whatever steps are appropriate (for
example, putting the device on line). For printers, the Native Mode Spooler
will attempt to recover to the start of the current page.
- 6035
- MESSAGE
Type manager; your I/O request was aborted due to a system power failure.
- CAUSE
Self-explanatory.
- ACTION
If the device is owned by a spooler, the spooler process will terminate.
Restart the process. For other situations, take whatever steps are
appropriate to re-establish normal device operation.
- 6036
- MESSAGE
Type manager; data lost.
- CAUSE
A lower level subsystem has reported an error of some kind which resulted in
an incomplete data transfer.
- ACTION
Check the lower level statuses to determine the root cause of the error.
- 6037
- MESSAGE
Type manager; the I/O request was aborted externally.
- CAUSE
Either you entered an explicit ABORTIO, or the process with outstanding I/O is
being terminated.
- ACTION
None.
- 6039
- MESSAGE
Type manager; the device reported a parity error.
- CAUSE
Self-explanatory.
- ACTION
Take whatever steps are appropriate, for example, cleaning tape heads. If the
problem persists, contact your Hewlett-Packard support engineer.
|