 |
» |
|
|
|
|  |  |
The Schema Processor accesses three files: The text file (DBSTEXT) containing the schema records and
Schema Processor commands for processing.
The list file (DBSLIST) containing the schema listing, if
requested, and error messages, if any.
The root file, if requested, created as a result of an
error-free schema.
Any file error which occurs while accessing any of these files
causes the Schema Processor to terminate execution. A message
indicating the nature of the error is sent to $STDLIST (and to
the list file, if the list file is different from $STDLIST). Schema Processor command errors may occur. They neither cause
termination nor do they prohibit the creation of a root file.
In some cases, however, the resultant root file will differ
from what might have occurred had the commands been error free.
Command errors are added to an error count which, if it exceeds
a limit, will cause the Schema Processor to
terminate execution. Note that if the LIST option is active, error messages for
command errors and syntax errors appear in the list file following
the offending statement. If the NOLIST option is active, only
the offending statement, followed by the error message, is
listed. Schema Processor File Errors |  |
Various file error messages are listed in this section. Each such
message is preceded by the character string: Additionally, the Schema Processor prints a standard MPE/iX file
information display on the $STDLIST file. - MESSAGE
READ ERROR ON file name
- CAUSE
FREAD error occurred on the specified file.
- ACTION
Check text file or :FILE command.
- MESSAGE
FILE ALREADY EXISTS; UNABLE TO CLOSE file name
- CAUSE
FCLOSE error occurred on specified file. May be caused by duplicate file in group with same name as root file.
- ACTION
Change database name or purge file of same name.
Or, be sure correct file and file name used.
Check :FILE commands used. If other cause,
consult MPE/iX Intrinsics Manual (32650-90028) for similar message.
- MESSAGE
UNABLE TO USE file name
- CAUSE
Specified file cannot be FOPENed or its characteristics make it unsuitable for its intended use.
- ACTION
Change database name or purge file of same name.
Or, be sure correct file and file name used. Check :FILE commands used.
If other cause, consult MPE/iX Intrinsics Manual (32650-90028) for similar message.
- MESSAGE
UNABLE TO WRITE LABEL OF file name
- CAUSE
FWRITELABEL error occurred on specified file.
- ACTION
Change database name or purge file of same name.
Or, be sure correct file and file name used. Check :FILE commands used.
If other cause, consult MPE/iX Intrinsics Manual (32650-90028) for similar message.
- MESSAGE
UNEXPECTED END-OF-FILE ON file name
- CAUSE
Call to FREAD or FWRITE on specified file has yielded unexpected end of file condition.
- ACTION
Change database name or purge file of same name. Or,
be sure correct file and file name used. Check :FILE commands used.
If other cause, consult MPE/iX Intrinsics Manual (32650-90028) for similar message.
- MESSAGE
WRITE ERROR ON file name
- CAUSE
FWRITE error occurred on the specified file.
- ACTION
Change database name or purge file of same name.
Or, be sure correct file and file name used. Check :FILE commands used.
If other cause, consult MPE/iX Intrinsics Manual (32650-90028) for similar message.
Schema Processor Command Errors |  |
Various Schema Processor command error
messages are listed in this section. Each such message is preceded by the character string: - MESSAGE
COMMAND CONTINUATION NOT FOUND
- CAUSE
If the schema processor command is continued to the next
record, the last non-blank character of the preceding
line must be an ampersand (&) and the continuation
record must start with a dollar sign ($).
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
- MESSAGE
COUNT HAS BAD FORMAT
- CAUSE
The numbers in ERRORS, LINES, or BLOCKMAX parameters of the
$CONTROL command are not properly formatted integer values.
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
- MESSAGE
ILLEGAL COMMAND
- CAUSE
The Schema Processor does not recognize the command.
Valid commands are $PAGE, $TITLE, and $CONTROL.
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
- MESSAGE
IMPROPER COMMAND PARAMETER
- CAUSE
One of the commands in the parameter is not valid.
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
- MESSAGE
MISSING QUOTATION MARK
- CAUSE
Character string specified in $PAGE or $TITLE command must
be bracketed by quotation marks (").
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
- MESSAGE
SPECIFIED TITLE IS TOO LONG
- CAUSE
Character string in $TITLE or $PAGE command exceeds 104
characters.
- ACTION
Examine the schema text file to find any incorrect commands. Edit the text file and run the Schema
Processor again.
Schema Syntax Errors |  |
Database definition syntax errors may be detected by the Schema
Processor. Their existence does not cause termination but does
prohibit root file creation. Discovery of one may trigger others
which disappear after the first is corrected. Also, detection of
one may preclude detection of others which appear after the first
is corrected. Syntax errors are also added to an error count
which, if excessive, will cause Schema Processor termination. Various syntax error messages are listed in this section. As with command
errors, each syntax error is preceded by the character string: - MESSAGE
AUTOMATIC MASTER DATA SET MUST HAVE SEARCH ITEM ONLY
- CAUSE
Automatic master data sets must contain entries with
only one data item. The data item must be a key item.
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD CAPACITY OR TERMINATOR
- CAUSE
Either the number in the CAPACITY: statement is not an integer between 1 and 2 -1, or a semicolon is missing.
- ACTION
Examine the schema text file to find the error and edit the file. Run the Schema Processor again.
- MESSAGE
BAD CHARACTER IN USER CLASS NUMBER
- CAUSE
User class number in password is not an integer from 1 to 63.
- ACTION
Examine the schema text file to find the error and edit the file. Run the Schema Processor again.
- MESSAGE
BAD DATA BASE NAME OR TERMINATOR
- CAUSE
Database name in BEGIN DATA BASE statement is not a
valid database name beginning with an alphabetic
character and having up to 6 alphanumeric
characters. Or, the name is not followed by a
semicolon (;).
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD DATA SET TYPE
- CAUSE
The data set type designator is not AUTOMATIC (or A),
MANUAL (or M), or DETAIL (or D).
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD DEVICE CLASS NAME
- CAUSE
The device class name specified contains an invalid character.
The name must be less than eight characters and begin with a
letter.
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD DEVICE CLASS NAME OR TERMINATOR
- CAUSE
The device class name specified contains an invalid character
or was not ended with a semicolon ";".
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD LANGUAGE
- CAUSE
Language name contains invalid characters, or the language
number is not a valid integer.
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD PATH CONTROL PART DELIMITER
- CAUSE
Data item defined as sort item in detail data set is
not properly delimited with parentheses ().
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD PATH COUNT OR TERMINATOR
- CAUSE
The path count in the master data set definition is
not an integer from 1 to 16 (for an automatic master), or
0 to 16 (for a manual master). This message may also mean the path
count is not followed by a quotation mark (").
- ACTION
Examine the schema text file to find the error and edit the file. Run
the Schema Processor again.
- MESSAGE
BAD PATH SPECIFICATION DELIMITER
- CAUSE
Name of master data set following search item name in detail
data set definition is not followed by a right parenthesis ")", or
by a sort item name in parentheses.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD READ CLASS OR TERMINATOR
- CAUSE
Read user class number defined for either a data set or
data item is not an integer from 0 to 63, or it is not
terminated by a comma (,) or slash (/).
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD SET NAME OR TERMINATOR
- CAUSE
The data set name does not conform to naming rules. (Names must start with a letter and may have up to 16 alphanumeric characters including
+ - * / ? ' # % & @.) Or the data set name is not
terminated by the correct character for the context
in which it appears.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD SUBITEM COUNT OR TERMINATOR
- CAUSE
Subitem count for a data item defined in schema item part
is not an integer from 1 to 255.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD SUBITEM LENGTH OR TERMINATOR
- CAUSE
Subitem length for data item defined in schema item is not
an integer from 1 to 255.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD TERMINATOR-';' EXPECTED
- CAUSE
Password or capacity was not followed by a semicolon.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD TERMINATOR- ';' OR ',' EXPECTED
- CAUSE
Items within an entry definition must be separated from each
other with commas and terminated with a semicolon.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD TYPE DESIGNATOR
- CAUSE
Data item defined in schema item part is not defined as
type I, J, K, R, U, X, Z, or P.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
BAD WRITE CLASS OR TERMINATOR
- CAUSE
Write user class number shown for the data set or
data item is not an integer from 0 to 63, or it
is not terminated by a right parenthesis ")" or comma.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
'CAPACITY:' EXPECTED
- CAUSE
CAPACITY statement must follow entry definition in the
definition of data sets in the set part of schema.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
DATA BASE HAS NO DATA SETS
- CAUSE
No data sets were defined in the set part of schema.
The database must contain at least one data set.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
DATA BASE NAME TOO LONG
- CAUSE
Database name has more than six characters.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
DUPLICATE ITEM SPECIFIED
- CAUSE
The same data item name was used more than once in
the entry definition of data sets.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
DUPLICATE SET NAME
- CAUSE
The same data set name was used to define more than
one data set in the set part of schema.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
'ENTRY:' EXPECTED
- CAUSE
Each set defined in the set part of schema must contain
ENTRY: statement followed by the data item names of the data
items in entry.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
ENTRY TOO BIG
- CAUSE
The number and size of the data items defined for an
entry makes an entry too big for maximum block size.
The block size is specified by $CONTROL, or BLOCKMAX=
command, or default.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
ENTRY TOO SMALL
- CAUSE
A detail data set that is not linked to any master data
set must have a data entry length of two or more halfwords.
This length is determined by adding the size in halfwords of
each data item defined in the data entry.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
ILLEGAL ITEM NAME OR TERMINATOR
- CAUSE
The data item name does not conform to naming rules. (Names must
start with a letter and may have up to 16 alphanumeric
characters including + - ? / # $ & * @ ). Or if in the
item part, it is not followed by a comma.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
ILLEGAL USER CLASS NUMBER
- CAUSE
User class number defined in schema password part is
not an integer between 1 and 63.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
ITEM TOO LONG
- CAUSE
The length of a single data item may not exceed 2047
halfwords.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
'LANGUAGE:' EXPECTED
- CAUSE
The Schema Processor expected to find a LANGUAGE statement
after the comma following the BEGIN DATA BASE name statement.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
LANGUAGE NOT SUPPORTED
- CAUSE
Language specified is not supported on
your system, or is not a valid language.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
MASTER DATA SET LACKS EXPECTED DETAIL(S)
- CAUSE
Master data set was defined with a non-zero data count,
but the number of detail search items which back-referenced
the master is less than the value of the path count.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
MASTER DATA SET LACKS KEY ITEM
- CAUSE
A master data set was defined without defining one of
the data items in the set as a key item.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
MORE THAN ONE KEY ITEM
- CAUSE
A master data set cannot be defined with more than one key
item.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
MORE THAN ONE PRIMARY MASTER
- CAUSE
User has defined more than one primary path for a
detail data set.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
'NAME:' OR 'END.' EXPECTED
- CAUSE
Schema Processor expected, at this point, to find the
beginning of another data set definition, or the end of
schema.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
NATIVE LANGUAGE SUPPORT ERROR
- CAUSE
NLS/3000 returned an error.
- ACTION
Notify the system manager
- MESSAGE
'PASSWORDS:' NOT FOUND
- CAUSE
'PASSWORDS:' statement must immediately follow the BEGIN
DATA BASE statement in schema. If it does not, DBSCHEMA
terminates execution.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
PASSWORD TOO LONG
- CAUSE
A password defined in data schema cannot exceed
eight characters.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
REFERENCED SET NOT MASTER
- CAUSE
The data set referenced by the detail data set search
item is another detail data set instead of a master
data set.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SCHEMA PROCESSOR LACKS NEEDED TABLE SPACE
- CAUSE
Schema Processor is unable to expand its data stack to accommodate
all of the translated information which will make up the root
file. It continues to scan the schema for the proper form, but
will not perform all of the checks for correctness nor will it
create a root file. To process the schema correctly, the
operating system must be configured with a larger maximum stack size.
- ACTION
Ask system manager to increase maximum stack size.
- MESSAGE
SEARCH OR KEY ITEM NOT SIMPLE
- CAUSE
All data items defined in data schema as key or search items must
be simple items.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SEARCH AND KEY ITEMS NOT OF SAME LENGTH
- CAUSE
Master key item must be the same length as any related
detail data set search item.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SEARCH AND KEY ITEMS NOT OF SAME TYPE
- CAUSE
Master key item must be of the same type as any related
detail data set search item.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SET HAS NO PATHS AVAILABLE
- CAUSE
More detail data set search items have specified a
relationship with a master data set than the number specified in
the master set's path count.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SORT ITEM OF BAD TYPE
- CAUSE
Data item defined as sort item must be of type U, K, or X.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SORT ITEM NOT IN DATA SET
- CAUSE
Detail data set's entry definition does not include an item
which is specified as a sort item for another item in the entry.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
SORT ITEM SAME AS SEARCH ITEM
- CAUSE
The same item cannot be both a search and a sort item for the
same path.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
TOO MANY DATA ITEMS
- CAUSE
The item part of schema cannot have more than 1023 data item
names
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
TOO MANY DATA SETS
- CAUSE
The database cannot have more than 199 data sets.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
TOO MANY ERRORS
- CAUSE
The specified or default number of errors has been
exceeded. Processing is terminated.
- ACTION
Correct the errors, or increase the ERROR parameter
value.
- MESSAGE
TOO MANY ITEMS SPECIFIED
- CAUSE
The data set entry cannot have more than 255 data items.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
TOO MANY PATHS IN DATA SET
- CAUSE
Detail data set entries cannot have more than 16 search items.
- ACTION
Examine the schema text file to find the error and edit the file.
Run the Schema Processor again.
- MESSAGE
UNDEFINED ITEM REFERENCED
- CAUSE
A data item appearing in the data set definition was not
previously defined in the item part of schema.
- ACTION
Examine the schema text file and find the incorrect statement. Edit it
and run the Schema Processor again.
- MESSAGE
UNDEFINED SET REFERENCED
- CAUSE
Master data set referenced by detail search item was not
previously defined in the set part of schema.
- ACTION
Examine the schema text file and find the incorrect statement. Edit it
and run the Schema Processor again.
|