- 1
- MESSAGE
A system error STACK OVERFLOW occurred.
- CAUSE
Number of error entries to PUSH into the Process Error Stack is greater than the Process Error Stack size.
- ACTION
Decrease the error entries or increase the Error Stack size.
- 2
- MESSAGE
A system error STACK UNDERFLOW occurred.
- CAUSE
Number of error entries to POP off the Process Error Stack is greater than the Error Stack size, or the Error Stack is empty.
- ACTION
Decrease the error entries or increase the Error Stack size.
- 3
- MESSAGE
The specified STACK ENTRY does not exist on the PROCESS ERROR STACK.
- CAUSE
The value of INDEX does not correspond to an error in the global error log, or in the Process Error Stack.
- ACTION
Check the STACK ENTRY and use the valid one.
- 4
- MESSAGE
CREATE_OBJECT failed in creating stack.
- CAUSE
In creating stack, an attempt to call CREAT_OBJECT failed; internal error.
- ACTION
Check CREATE_OBJECT.
- 5
- MESSAGE
RELEASE_OBJECT failed in releasing stack.
- CAUSE
In releasing stack, an attempt to call RELEASE_OBJECT failed; internal error.
- ACTION
Check RELEASE_OBJECT.
- 6
- MESSAGE
The specified error number is a zero, which is invalid.
- CAUSE
User specifies zero as an error number which is invalid in the System Catalog file.
- ACTION
Use the valid number( > 0, < 0).
- 7
- MESSAGE
The specified subsystem number is not valid.
- CAUSE
User specified an invalid SUBSYS number (<= 0) or the SUBSYS number is not in the System Catalog.
- ACTION
Use the correct SUBSYS number.
- 8
- MESSAGE
The specified buffer is too small to hold the text of the error message; the message has been truncated.
- CAUSE
The value of BUF_LEN is smaller than the actual message in the System Catalog being returned. The message has been truncated.
- ACTION
Increase the buffer size to hold the entire text.
- 9
- MESSAGE
The requested depth is outside of the valid range for the PROCESS ERROR STACK.
- CAUSE
User specified the depth outside of the Process Error Stack range. It has to be in the range between 1 and 16.
- ACTION
Use the valid stack depth, which is between 1 and 16.
- 10
- MESSAGE
An error occurred while attempting to create a KSO for use by the ERROR MANAGEMENT subsystem.
- CAUSE
An error was encountered in attempting to create the global system error log object or a KSO.
- ACTION
Check the system.
- 11
- MESSAGE
The ERROR MANAGEMENT subsystem was unable to get a pointer to one of its KSOs.
- CAUSE
An error occured in attempting to get a pointer to the global system error log or the KSO which holds parameters.
- ACTION
Check the global system error log or KSO.
- 12
- MESSAGE
The specified STACK ENTRY does not exist in the SYSTEM ERROR STACK.
- CAUSE
The value of DEPTH does not correspond to an error in the System Error Stack.
- ACTION
Check the value of DEPTH and System Error Stack.
- 15
- MESSAGE
A RECOVER statement was unexpectedly invoked in the ERROR MANAGEMENT subsystem.
- CAUSE
An unexpected trap occurred which caused the RECOVER block to be invoked.
- ACTION
Check the error trap.
- 16
- MESSAGE
An attempt was made to access process error stack by a caller running on the ICS.
- CAUSE
The caller is on ICS and, therefore, no operation was performed when attempting to access process error stack.
- ACTION
Do not access process error stack when the caller is on ICS.
- 17
- MESSAGE
An error occurred while attempting to close the System Catalog.
- CAUSE
When trying to close the System Catalog, an error occured.
- ACTION
Check the System Catalog. You must open it before you can close it.
- 18
- MESSAGE
The process error stack is empty.
- CAUSE
User is trying to access the process error stack and there are no errors in the stack.
- ACTION
Check the process error stack before accessing it.
- 19
- MESSAGE
An error occurred while attempting to open the System Catalog; error messages cannot be obtained.
- CAUSE
User is trying to open the System Catalog to access the error message and it failed.
- ACTION
Check System Catalog.
- 23
- MESSAGE
The BUFFER and BUF_LEN parameters must be supplied in order to return the text of the specified error to the caller.
- CAUSE
User specified a message to go into buffer and BUFFER and BUF_LEN parameters are not there.
- ACTION
Check the parameters and provide BUFFER and BUF_LEN parameters.
- 24
- MESSAGE
The requested display option is invalid.
- CAUSE
User is trying to use an invalid display option to display errors.
- ACTION
Check the requested display option and use the correct one.
- 25
- MESSAGE
There is no message set in the System Catalog which corresponds to the subsystem number in the specified status.
- CAUSE
User is trying to use the invalid subsystem set number to access the System Catalog.
- ACTION
Check the System Catalog or use the valid subsystem set number.
- 26
- MESSAGE
There is no error number in the System Catalog which corresponds to the specified status.
- CAUSE
User is tring to use the invalid error number to access the error message from System Catalog.
- ACTION
Check the System Catalog or use the valid error number.
- 27
- MESSAGE
The specified number of message parameters to push is invalid; valid range is from 1 to 5.
- CAUSE
The value of message parameters is not in the range. The valid range is from 1 to 5.
- ACTION
Check the value of message parameters and use the valid one.
- 28
- MESSAGE
One of the message parameters to be pushed is not a valid string parameter.
- CAUSE
One of the string parameters specified is invalid, meaning that the delimiter in the beginning of the string was not found prior to the maximum number of
characters allowed in the string.
- ACTION
Check the string parameter and correct it.
- 200
- MESSAGE
WARNING ** The error management subsystem was unable to open the System Catalog; error messages cannot be obtained.
- CAUSE
When the user tried to access the System Catalog to obtain error messages, an error occurred.
- ACTION
Check the System Catalog or Error messages.
- 201
- MESSAGE
WARNING ** Message set ! was not found in the System Catalog.
- CAUSE
If the user is trying to access System Catalog with an invalid subsystem number, this warning message is issued.
- ACTION
Check the System Catalog and use the valid number.
- 202
- MESSAGE
WARNING ** Message set !, Error number ! was not found in the System Catalog.
- CAUSE
When the user is trying to access the System Catalog with invalid subsystem numbers and error number, this warning message is issued.
- ACTION
Check the subsystem and error number before accessing the System Catalog.
- 203
- MESSAGE
WARNING ** An unexpected error was encountered while reading error messages from the System Catalog.
- CAUSE
When the user tried to query the System Catalog with subsystem numbers and message numbers, an internal error occurred.
- ACTION
Check the subsystem numbers and message numbers.
- 204
- MESSAGE
The ERROR MANAGEMENT subsystem was unable to initialize its semaphore.
- CAUSE
When the ERROR MANAGEMENT subsystem tried to call the Control Block routine to initialize its semaphore, an internal error occurred.
- ACTION
Check the internal error and contact the Control Block routines owner.
- 205
- MESSAGE
WARNING ** One or more entries on the error stack have been overwritten.
- CAUSE
If the user tried to dump the entire error stack and some entries were overwritten, this warning message is issued to warn the user of that fact.
- ACTION
Check the error stack.
- 501
- MESSAGE
The menu selection is not valid; select from the menu choices only.
- CAUSE
User has entered a character string which does not match any of the options specified in the accompanying menu of choices.
- ACTION
Enter only the indicated selections.
- 502
- MESSAGE
The specified INFO string is longer than allowed.
- CAUSE
User has entered an INFO string which is larger than the program can handle.
- ACTION
The program will handle an INFO string with the largest possible subsystem INFO string. Entries must be limited to 50 characters between the quotations.
- 503
- MESSAGE
Only numeric digits (0...9) and an optional sign indicator (+, -) are allowed.
- CAUSE
Numeric entries may contain a leading "+" or "-", but all other characters must be digits only. Blanks (other than leading or trailing blanks) are not allowed.
- ACTION
Enter a valid numeric quantity.
- 504
- MESSAGE
The specified time code contains an invalid date and/or time.
- CAUSE
The time stamp code provided is not recognized by the system conversion procedures.
- ACTION
Check the time code and re-enter correctly.
- 505
- MESSAGE
An internal failure of NATIVE LANGUAGE SUPPORT intrinsic occurred.
- CAUSE
Unexpected error of an unknown nature returned from NLS.
- ACTION
Notify your support engineer. An error stack dump may indicate the precise nature of the error.
- 506
- MESSAGE
NATIVE LANGUAGE SUPPORT is not available on this system.
- CAUSE
This is an unexpected error which should have been detected at the start of the program and corrected by bypassing Native Language support.
- ACTION
Notify your support engineer.
- 508
- MESSAGE
The subsystem was specified without a corresponding message number.
- CAUSE
The message number (second parameter) was left blank after specifying a subsystem number.
- ACTION
Either provide a message number or delete the subsystem number from the INFO string.
- 509
- MESSAGE
A message number was specified without a corresponding subsystem number.
- CAUSE
A message number was specified but the subsystem number (first parameter) was left blank.
- ACTION
You must either specify both a subsystem number and message number or neither.
- 510
- MESSAGE
The specified number is outside the permissible range of 1...32766.
- CAUSE
The user has provided a number less than 0 or greater than one less than maxshortint. (One less than maxshortint is a message catalog limitation).
- ACTION
Restrict entries to the indicated range.
- 511
- MESSAGE
The specified number is outside the permissible range of 1...2147483647.
- CAUSE
The user has provided a number less than 0 or greater than maxint.
- ACTION
Restrict entries to the indicated range.
- 512
- MESSAGE
The specified number is outside the permissible range of 1...9223372036854775807.
- CAUSE
The user has provided a number less than 0 or greater than maxlongint.
- ACTION
Restrict entries to the indicated range.
- 513
- MESSAGE
The specified number is larger/smaller than the largest/smallest integer which this system can handle.
- CAUSE
The user has provided a number that this system can not handle.
- ACTION
Check the number and use a correct one.
- 514
- MESSAGE
An unexpected problem was encountered while trying to convert a string to a number.
- CAUSE
When trying to convert a string to a number, an internal error was encountered.
- ACTION
Check the string.
- 515
- MESSAGE
Too few parameters were specified in the INFO string.
- CAUSE
Syntax error. Parameters may be nil, but their corresponding delimiters must be present.
- ACTION
Adhere to required syntax. The INFO string for this program must contain a minimum of two parameters. If you need help on syntax, type "HELP MSGUTIL".
- 516
- MESSAGE
The name for the specified subsystem could not be obtained.
- CAUSE
The user has provided a subsystem number which is not in the System Catalog.
- ACTION
Check the System Catalog or use the right number.
- 534
- MESSAGE
Unable to display Message #
- ACTION
Information only.
- 550
- MESSAGE
WARNING - Time/date display capabilities could not be activated.
- CAUSE
The program could not adequately initialize range checking for time codes. Therefore, time code conversions will not be accepted. This error is unexpected and may be system dependent.
- ACTION
Other functions of the program will continue to function. Notify your support engineer.
- 551
- MESSAGE
WARNING - Extra, unused parameters were specified in the INFO string.
- CAUSE
More than three parameters have been supplied. MSGUTIL ignored all past those first three.
- ACTION
Adhere to the required syntax.
|