  | 
»  | 
 | 
  
 | 
 | 
 |   |   |   
- 10
 
 - MESSAGE
 The code segment number is invalid.
  - CAUSE
 The caller passed in a code segment which is invalid for the process whose PIN was passed in, or the code segment is unassigned.
 - ACTION
 None.
 
 
  
 - 30
 
 - MESSAGE
 The data segment number is invalid.
  - CAUSE
 The caller passed in an invalid or an unassigned data segment number.
 - ACTION
 None.
 
 
  
 - 60
  
 - MESSAGE
 FREEZE returned a bad status.
  - CAUSE
 The memory manager failed to freeze a compatibility mode code or data segment into memory.
 - ACTION
 Examine the process error stack to determine what may have caused the problem.
 
 
  
 - 65
 
 - MESSAGE
 UNFREEZE returned a bad status.
  - CAUSE
 The memory manager failed to unfreeze a compatibility mode code or data segment into memory.
 - ACTION
 Examine the process error stack to determine what may have caused the problem.
 
 
  
 - 160
 
 - MESSAGE
 SWITCH_TO_CM returned a bad status.
  - CAUSE
 Corruption of an operating system data structure or operating system code caused SWITCH_TO_CM to fail.
 - ACTION
 Examine the process error stack to determine what may have caused the problem.
 
 
  
 - 301
 
 - MESSAGE
 The logical device parameter is not a real device.
  - CAUSE
 An attempt was made to place a non-existent device or a spooler virtual device into diagnostic mode.
 - ACTION
 None.
 
 
  
 - 302
 
 - MESSAGE
 The device is currently not in diagnostic mode.
  - CAUSE
 An attempt was made to remove a device not owned by the diagnostic system from the diagnostic mode.
 - ACTION
 None.
 
 
  
 - 304
 
 - MESSAGE
 The device is already in diagnostic mode.
  - CAUSE
 An attempt was made to place a device which was already owned by the diagnostic system into the diagnostic mode.
 - ACTION
 None.
 
 
  
 - 305
 
 - MESSAGE
 The device is currently in use.
  - CAUSE
 An attempt was made to place a device currently being accessed by a user into the diagnostic mode.
 - ACTION
 Try again once the user is no longer accessing the device.  The SHOWDEV command can be used to determine the current owner.
 
 
  
 - 309
 
 - MESSAGE
 The spooler for the device could not be stopped.
  - CAUSE
 While attempting to place a device into the diagnostic mode, the system could not stop the spooler active on the device.
 - ACTION
 Use the STOPSPOOL command to stop the spooler.  If sucessful, attemp the diagnostic again.
 
 
  
 - 311
 
 - MESSAGE
 The spooler for the device could not be restarted.
  - CAUSE
 While removing the device from the diagnostic mode, the system could not restart a spooler for the device.
 - ACTION
 If desired, use the STARTSPOOL command on the console to start a spooler for the device.
 
 
  
 - 312
 
 - MESSAGE
 The spooler for the device could not be suspended.
  - CAUSE
 While attempting to place a device into diagnostic mode, the system could not suspend the currently active spoolfile.
 - ACTION
 Try using the SUSPENDSPOOL command on the console to suspend the currently active spoolfile.
 
 
  
 - 320
 
 - MESSAGE
 The logical console cannot be placed in diagnostic mode.
  - CAUSE
 An attempt was made to place the logical console into diagnostic mode.
 - ACTION
 Move the logical console to another terminal using the CONSOLE command.
 
 
  
 - 321
 
 - MESSAGE
 Disks cannot be placed in diagnostic mode.
  - CAUSE
 An attempt was made to place a disk into diagnostic mode.
 - ACTION
 None.
 
 
  
 - 2550
 
 - MESSAGE
 GETSIR returned a bad status to the fast switch stub.
  - CAUSE
 Corruption of an operating system data structure or operating system code caused GETSIR to fail.
 - ACTION
 Perform a system dump.  Reboot the system using START.
 
 
  
 - 2551
 
 - MESSAGE
 RELSIR returned a bad status to the fast switch stub.
  - CAUSE
 Corruption of an operating system data structure or operating system code caused RELSIR to fail.
 - ACTION
 Perform a system dump.  Reboot the system using START.
 
 
  
  
 |