- -23
- MESSAGE
CS80_UNIT_AVAILABLE
A multi-unit disk device has notified the host system that a disk unit that was
previously locked by another host system has now been unlocked, and is now
available for use.
- CAUSE
The host system receiving this status had previously attempted to access a unit
that was locked by another host system. That attempted access was rejected due
to the unit lock imposed by the other host system. The lock has been removed.
- ACTION
Since MPE/iX does not yet support multi-unit disk devices, the host system
should never receive this notification. If it does, either a hardware error or
system software error has occurred. Call your Hewlett-Packard representative.
- -24
- MESSAGE
CS80_LOST_SPINDLE_SYNCH
A multi-mechanism disk controller has detected that the mechanisms within the
device are no longer rotationally synchronized within the specified tolerance.
- CAUSE
Some hardware problem within one or more of the disk mechanisms is causing the
spindle synchronization circuitry to lose synchronization lock.
- ACTION
Continue to use the disk. It will operate correctly even if spindle synch is
lost. Its speed of operation will be somewhat reduced. Call your Hewlett-Packard Representative to discuss the problem further.
- -25
- MESSAGE
CS80_MECHANISM_SKIPPED
A multi-mechanism disk array device controller has detected that one of the
"striped with parity" disk mechanisms is UNASSIGNED: present, not broken, but
not part of a logical unit. The "skipped" mech is not being used by the device.
- CAUSE
A mechanism has been physically removed and replaced with another mechanism,
or the disk diagnostic program has issued a Set Skip Drive command, and, in
either case, the disk's REBUILD operation has not yet been performed.
- ACTION
Use the FLEXDIAG diagnostic program to perform a REBUILD operation on the
disk device. After successful REBUILDing, the mechanism that was being skipped
will no longer be skipped: it will be assigned to the striped logical unit.
- -179
- MESSAGE
CS80_STRIPED_XOR_ERROR
A multi-mechanism disk array device controller has detected an XOR Error on a
Read Data operation on a Striped With Parity disk device. The parity computed
from the striped data did not match the parity stored on the Data Protect disk.
- CAUSE
1) Failure to properly format a Striped With Parity disk device.
2) Reading data from an area of the disk media that had not been completely
written.
- ACTION
Call your Hewlett-Packard Representative.
- -180
- MESSAGE
CS80_UNKNOWN_HW_STATUS_CLASS
The hardware status from the disk device could not be recognized by the system
software because the value of the first byte of status (the "status class") was
not one of the legal values defined for the device.
- CAUSE
Hardware problem in the disk device or in the cabling or interfaces between the
disk device and the host system.
- ACTION
Call your Hewlett-Packard Representative.
- -181
- MESSAGE
CS80_UNKNOWN_HARDWARE_ERR
The hardware status from the disk device could not be recognized by the system
software because the value of the second byte of status was not one of the
legal values defined for the Hardware Error status class.
- CAUSE
Hardware problem in the disk device or in the cabling or interfaces between the
disk device and the host system.
- ACTION
Call your Hewlett-Packard Representative.
- -182
- MESSAGE
CS80_UNKNOWN_RESOURCE_ERR
The hardware status from the disk device could not be recognized by the system
software because the value of the second byte of status was not one of the
legal values defined for the Resource Error status class.
- CAUSE
Hardware problem in the disk device or in the cabling or interfaces between the
disk device and the host system.
- ACTION
Call your Hewlett-Packard Representative.
- -183
- MESSAGE
CS80_UNKNOWN_COMMAND_ERR
The hardware status from the disk device could not be recognized by the system
software because the value of the second byte of status was not one of the
legal values defined for the Command Error status class.
- CAUSE
Hardware problem in the disk device or in the cabling or interfaces between the
disk device and the host system.
- ACTION
Call your Hewlett-Packard Representative.
- -184
- MESSAGE
CS80_NO_SELFTEST_PERFORMED
The disk array controller on a disk array device that is a "link device" (i.e.
is directly connected to the host system by fiber-optic cable) has rejected a
device-wide selftest command that was issued by the host system.
- CAUSE
Diagnostic program software error. Diagnostic programs should not issue device
-wide selftest commands to disk array devices when they are "link devices". The
disk array controllers are designed to reject such commands.
- ACTION
Check to see that the diagnostic program is being run correctly. If it is,
and this error persists, call your Hewlett-Packard Representative.
- -185
- MESSAGE
CS80_CONFIGURATION_FAULT
During a device power-on selftest, the disk array device controller could not
satisfy the device configuration (operating mode) that was specified by the
settings of the device's front-panel configuration switches.
- CAUSE
Device installation error or hardware failure. Either the configuration switch
settings are wrong, or the drive modules are wrongly located in the disk array
module slots, or one or more drive modules have failed.
- ACTION
Check for and correct improper configuration switch settings or drive module
placements. Check for failed drive modules. If none of these checks reveal
and correct the problem, then call your Hewlett-Packard representative.
- -186
- MESSAGE
CS80_FIRMWARE_UPGRADE_MODE
A host system has issued a transaction to a disk array device at a time when
the device cannot perform the transaction, due to a lack of operational firmware in the disk array device controller.
- CAUSE
The host system, under diagnostic program control, attempted to upgrade the
controller firmware in the disk array device controller (by downloading new
firmware), and that upgrade operation did not complete successfully.
- ACTION
Call your Hewlett-Packard Representative.
- -187
- MESSAGE
CS80_TOO_MANY_SPARES
The disk device controller has rejected a SPARE BLOCK command issued by the
host system. The command was rejected because ten or more SPARE BLOCK commands
had already been given to the device since it was last powered-on.
- CAUSE
Probably a hardware problem in the disk device has been causing the disk device
to report an excessive number of Unrecoverable Read errors to the host system,
thus causing the host to issue an excessive number of SPARE BLOCK commands.
- ACTION
Call your Hewlett-Packard Representative.
- -188
- MESSAGE
CS80_MECHANISM_FAULT
The disk array device controller has detected sufficient error conditions in
one of the disk mechanisms to cause the controller to declare the mechanism to
be faulty. The controller has removed the mechanism from service.
- CAUSE
A mechanism within a disk array device has exceeded its allowable error
threshold.
- ACTION
Call your Hewlett-Packard Representative. If this is a Parity-Protected disk
array device and this is the only mechanism that has faulted, then the device
will continue to operate correctly. If not, the device will go "offline".
- -189
- MESSAGE
CS80_UNABLE_TO_SKIP_MECH
CS80 hardware status indicates that the device has received an improper "Set
Skip Drive" command from the host system. The command was improper because its
execution would have caused the disk unit to "go offline" and be inoperable.
- CAUSE
In disk array devices, either a Parity-Protected Striped Unit already has one
"skipped" or "faulted" mechanism (and so cannot tolerate another skipped mechanism)
or else a Non-Parity-Protected Unit has been asked to skip a mechanism; it can't.
- ACTION
This condition indicates improper operation by or of the host system's disk
diagnostic software. Check to see that the diagnostic program is being run
correctly. If it is, and the problem persists, call your Hewlett-Packard Representative.
- -190
- MESSAGE
CS80_VIRT_CIRCUIT_IN_USE
Disk hardware status indicates that the device received a new command that used
the same Virtual Circuit Number as a previous command that is still executing.
- CAUSE
Possible intermittent problem in disk hardware, cabling or interface hardware,
or a system software error.
- ACTION
If the problem persists, take a system dump, and call your Hewlett-Packard
Representative.
- 312
- MESSAGE
DISK ARRAY HAS DISABLED A MECHANISM IN LDEV #.
NOW IN DATA RECOVERY MODE. NO DATA LOST OR CORRUPTED.
OPERATION MAY CONTINUE. PLEASE PLACE SERVICE CALL SOON.
- CAUSE
A mechanism in the disk array has suffered a failure. The disk array is
in data recovery mode and no immediate action need be taken on the part
of the user.
- ACTION
This message will be repeated on the console once a minute until the
operator acknowledges that he has seen it by replying 'yes' to it.
A service call should be placed in the near future.
- 313
- MESSAGE
ACKNOWLEDGE DISABLED MECHANISM IN DISK ARRAY IN LDEV #
- CAUSE
This is the acknowledgement message which corresponds to the repeating
message regarding the disabled mechanism in the disk array.
- ACTION
This message must be replied to (Y) in order to stop the repeating
message.
|