- 1
- MESSAGE
Only the user-specified length of data was transferred; however, the DEVICE MANAGER attempted to transfer more for some reason.
- CAUSE
User requested a data transfer, but the buffer supplied was zero bytes long.
- ACTION
Call your support representative.
- 2
- MESSAGE
UNLOCK Request was received; however, the DEVICE MANAGER was already unlocked.
- CAUSE
Diagnostics attempted to UNLOCK the Device Manager unnecessarily.
- ACTION
Call your support representative.
- 3
- MESSAGE
RELEASE is ALLOWED for operator requests; therefore, the disk pack is allowed to be dismounted.
- CAUSE
The front panel button used to spin down a disk pack is disabled.
- ACTION
None.
- 4
- MESSAGE
RELEASE will be denied for operator requests; therefore, the disk pack can not be dismounted.
- CAUSE
The front panel button used to spin down a disk pack is disabled.
- ACTION
None.
- 5
- MESSAGE
A DEVICE UNLOCK was requested, but the device was not locked.
- CAUSE
Device reservation for exclusive access was removed unnecessarily.
- ACTION
None.
- 6
- MESSAGE
DEVICE LOCK was requested, but the device was already locked by this host.
- CAUSE
Device reservation for exclusive access attempted, but it was already granted.
- ACTION
None.
- 7
- MESSAGE
A bit in the CS80 Hardware status information field was set for which there is no value defined.
- CAUSE
Device returned an undefined Warning/Info status.
- ACTION
Call your support representative.
- 8
- MESSAGE
The device missed a revolution during this transfer.
- CAUSE
Occurs normally on occasion.
- ACTION
None.
- 9
- MESSAGE
The bit in the CS80 hardware status was set, which indicates that the logs on the device are full.
- CAUSE
Error logs in the device are full.
- ACTION
Call your support representative.
- 10
- MESSAGE
The bit in the CS80 hardware status was set, which indicates that the data in this transfer was corrected by the device.
- CAUSE
Data was recovered with little difficulty.
- ACTION
None.
- 11
- MESSAGE
The bit in the CS80 hardware status was set, which indicates that the data was corrected by the device with difficulty.
- CAUSE
Data was recovered, but sector should be spared.
- ACTION
Call your support representative.
- 12
- MESSAGE
The bit in the CS80 Hardware status was set, which indicates that the data was corrected in more than one sector during this transfer. The sector number in the error log is of the first corrected one, only.
- CAUSE
Data was recovered, but sectors should be spared.
- ACTION
Call your support representative.
- 13
- MESSAGE
The bit in the CS80 hardware status was set, indicating that a defective sector was AUTOMATICALLY SPARED by the device.
- CAUSE
Device performed automatic sparing. Data was recovered.
- ACTION
None.
- 14
- MESSAGE
The bit in the CS80 hardware status was set, indicating that a LATENCY in the data transfer occurred.
- CAUSE
Additional rotation of spindle needed.
- ACTION
None.
- 15
- MESSAGE
The bit in the CS80 hardware status was set, indicating that only one spare track remains on the disk.
- CAUSE
Excessive sparing has been necessary with this media.
- ACTION
Call your support representative.
- 16
- MESSAGE
The bit in the CS80 hardware status was set, indicating that the device is requesting release to perform head alignment. The DEVICE MANAGER will grant.
- CAUSE
Automatic head alignment/diagnostics was performed.
- ACTION
None.
- 17
- MESSAGE
The bit in the CS80 Hardware status was set, indicating that the diagnostic frontpanel was manipulated causing a REQUEST for RELEASE.
- CAUSE
User activated front panel diagnostics.
- ACTION
Verify by looking at front panel.
- 18
- MESSAGE
The bit in the CS80 hardware status was set, indicating that the operator button was pushed, causing a REQUEST for RELEASE.
- CAUSE
User attempted to spin-down disk pack.
- ACTION
Either push button back in, or remove pack.
- 19
- MESSAGE
An error occurred previously which caused the request to be RETRIED by the DEVICE MANAGER. The retry was SUCCESSFUL.
- CAUSE
I/O was retried.
- ACTION
None.
- 20
- MESSAGE
The DOBIND was successful. However, the DEVICE ADAPTER MANAGER is of an incorrect revision.
- CAUSE
Software versioning problem.
- ACTION
Call your support representative.
- 21
- MESSAGE
The DOBIND was successful. However, the initialization of hardware received a TIMEOUT.
- CAUSE
Device did not respond when initialization was attempted.
- ACTION
Depends if device is supposed to be powered on.
- 22
- MESSAGE
The DOBIND was successful. However, the initialization of hardware received a DEVICE ERROR.
- CAUSE
Device responded with an initialization error.
- ACTION
Call your support representative.
- 191
- MESSAGE
The subsystem number in the received message was incorrect, usually during configuration.
- CAUSE
Configuration problem.
- ACTION
Verify your configuration and call your support representative.
- 192
- MESSAGE
A BIND request was received, but already was bound.
- CAUSE
Configuration problem.
- ACTION
Verify your configuration and call your support representative.
- 193
- MESSAGE
Data received from LOOPBACK did not match original data.
- CAUSE
Hardware problem during loopback test.
- ACTION
Call your support representative.
- 194
- MESSAGE
A request was received which requires the manager to be locked, but it is not locked.
- CAUSE
Diagnostics attempted destructive test on unreserved device.
- ACTION
Call your support representative.
- 195
- MESSAGE
An UNBIND request was received to UNBIND from incorrect HIGHER MANAGER port number.
- CAUSE
Unconfiguration process problem.
- ACTION
Call your support representative.
- 196
- MESSAGE
A DO_UNBIND request was received with the incorrect LOWER MANAGER port number.
- CAUSE
Unconfiguration process problem.
- ACTION
Call your support representative.
- 197
- MESSAGE
The memory request to RELEASE MEMORY (during Die request processing) failed.
- CAUSE
System software response problem.
- ACTION
Take a system dump.
- 198
- MESSAGE
An attempt to UNBIND failed due to pending I/Os from an external requester, or attempt to DO_UNBIND failed due to any pending I/Os for this manager.
- CAUSE
Unconfiguration inhibited as device busy.
- ACTION
Try again. If the error persists, call your support representative.
- 199
- MESSAGE
Update of the BAD SECTOR TABLE (which lists all sectors which should be spared because the manager detected recoverable or unrecoverable read errors) failed.
- CAUSE
Hardware problem or power failure during Bad Sector Table update.
- ACTION
Call your support representative.
- 200
- MESSAGE
BIND of this manager to the DEVICE ADAPTER MANAGER failed.
- CAUSE
Initialization of lower level (Device Adapter, etc.) failed.
- ACTION
Examine configuration file. Call your support representative.
- 201
- MESSAGE
An attempt to acquire memory for auxiliary data area failed.
- CAUSE
System software resource exhausted.
- ACTION
Take a system dump.
- 202
- MESSAGE
An attempt to acquire a message frame failed.
- CAUSE
System software resource exhausted.
- ACTION
Take a system dump.
- 203
- MESSAGE
Bad parity detected in data transfer.
- CAUSE
Fiber-optic connected disk has bad parity over fiber link.
- ACTION
Call your support representative.
- 204
- MESSAGE
User's buffer is incorrect for the request; either not present, nil pointer, or (for LOOPBACK only) not a virtual buffer.
- CAUSE
System problem.
- ACTION
Call your support representative.
- 205
- MESSAGE
An attempt to spare a block resulted in unexpected data errors in the new block.
- CAUSE
Device verifies new sector during spare. Detected new sector was also bad.
- ACTION
Call your support representative and try sparing block once again.
- 206
- MESSAGE
Request was cancelled by an abort.
- CAUSE
May have been caused by a power failure.
- ACTION
None.
- 207
- MESSAGE
A TIMEOUT has occurred, indicating that the drive is not talking to the manager.
- CAUSE
Device was not responding.
- ACTION
Check device and cabling; may be due to a power failure.
- 208
- MESSAGE
A request was made of the manager, but the manager is currently LOCKED by another higher manager (usually DIAGNOSTICS).
- CAUSE
Device accessed by diagnostics.
- ACTION
Terminate "sysdiag" session; try again.
- 209
- MESSAGE
An internal table entry in this manager was inconsistent; couldn't get or release the table entry desired.
- CAUSE
Software problem.
- ACTION
Take a system dump. Call your support representative.
- 210
- MESSAGE
An attempt to release a MESSAGE FRAME failed.
- CAUSE
System software problem.
- ACTION
Take a system dump. Call your support representative.
- 211
- MESSAGE
An attempt to SEND a message failed.
- CAUSE
System software resource depleted.
- ACTION
Take a system dump. Call your support representative.
- 212
- MESSAGE
An error bit was set in the ACCESS field of the CS80 hardware status that is undefined.
- CAUSE
CS80 device status returned invalid information.
- ACTION
Call your support representative.
- 213
- MESSAGE
Either an error bit in the FAULT field of the CS80 hardware status which is undefined was set, OR the DEVICE ADAPTER MANAGER returned LLIO_HW_PROBLEM status, OR Diagnostics previously set the DEVICE MANAGER state to BROKEN.
- CAUSE
May be hardware problem.
- ACTION
Call your support representative.
- 214
- MESSAGE
An error bit in the REJECT field of the CS80 hardware status was set which is undefined.
- CAUSE
CS80 device status returned invalid information.
- ACTION
Call your support representative.
- 215
- MESSAGE
An invalid unit number was returned in the CS80 hardware status.
- CAUSE
CS80 device status returned invalid information.
- ACTION
Call your support representative.
- 216
- MESSAGE
An invalid QSTAT was returned in CS80 hardware status.
- CAUSE
The QSTAT from device was not defined.
- ACTION
Call your support representative.
- 217
- MESSAGE
The DEVICE ADAPTER MANAGER returned a bad status in the status field of the DAM Reply message.
- CAUSE
Problem in the device adapter level; could be due to a power failure.
- ACTION
Monitor the process.
- 218
- MESSAGE
Immediate status indicates link protocol or port event errors occur.
- CAUSE
Fiber-optic connected disk interface problem. Could be due to a power failure.
- ACTION
If problem persists, call your support representative.
- 219
- MESSAGE
An incorrect META language was specified during configuration.
- CAUSE
Configuration or software version incorrect.
- ACTION
Call your support representative.
- 220
- MESSAGE
An invalid hardware address was specified during configuration.
- CAUSE
Configuration of device address incorrect or out of range.
- ACTION
Examine configuration files.
- 221
- MESSAGE
The disk driver has an internal data structure error.
- CAUSE
Critical software resource problem.
- ACTION
Take a system dump. Call your support representative.
- 222
- MESSAGE
The INTERNAL TABLE is inconsistent.
- CAUSE
Software problem.
- ACTION
Take a system dump. Call your support representative.
- 223
- MESSAGE
The DEVICE MANAGER received a request which it could not understand OR is not currently supported.
- CAUSE
The application attempted an inappropriate action for the device.
- ACTION
Take a system dump and call your Hewlett-Packard Service Representative.
- 224
- MESSAGE
A message was received which is inappropriate for the current DEVICE MANAGER state, (e.g., an I/O request prior to DOBIND).
- CAUSE
Software problem.
- ACTION
Call your support representative.
- 225
- MESSAGE
The transaction was aborted due to SYSTEM POWERFAIL.
- CAUSE
Power failure occurred while transaction was active.
- ACTION
None.
- 226
- MESSAGE
The CYCLIC REDUNDANCY CHECK of the data transaction failed.
- CAUSE
Transmission problem; possible cabling problem.
- ACTION
Verify cabling; call your support representative.
- 227
- MESSAGE
The ALINK DEVICE ADAPTER is indicating the fiber-optic link is non-functional, possibly due to a power failure.
- CAUSE
Fiber-optic connected disk interface broken. Maybe due to power failure.
- ACTION
Monitor the process; if problem persists, call your support representative.
- 228
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to access beyond the END OF VOLUME.
- CAUSE
Addressed block beyond volume range.
- ACTION
Should not occur with single volume devices. Call your support representative.
- 229
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to access beyond an END OF FILE.
- CAUSE
A file mark was detected; should not occur on disks.
- ACTION
Call your support representative.
- 230
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an UNRECOVERABLE DATA ERROR. The sector number is entered into the BAD SECTOR TABLE.
- CAUSE
Data was lost due to bad sectors.
- ACTION
Call your support representative.
- 231
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates more than one sector had UNRECOVERABLE DATA ERRORS. The first bad sector number is placed in the BAD SECTOR NUMBER.
- CAUSE
Data was lost due to bad sectors.
- ACTION
Call your support representative.
- 232
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to read UNITIALIZED DATA.
- CAUSE
Data uninitialized at address location.
- ACTION
Call your support representative.
- 233
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to write to a "READ ONLY" device.
- CAUSE
Device does not allow writes.
- ACTION
Verify the device is active. Call your support representative.
- 234
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates the heads are NOT LOADED as yet.
- CAUSE
A transient not ready condition existed.
- ACTION
Power on the device. Call your support representative.
- 235
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to SPARE FAILED due to no more spare sectors available.
- CAUSE
Spare command failed.
- ACTION
Call your support representative.
- 236
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates an attempt to access UNFORMATTED MEDIA.
- CAUSE
Disk was not initialized.
- ACTION
Call your support representative.
- 237
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the CS80 protocol requested too many operations at one time.
- CAUSE
Software problem or cabling problem.
- ACTION
Call your support representative.
- 238
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the device requires the I/O to be tried again.
- CAUSE
Device required I/O; usually due to auto head alignment.
- ACTION
None.
- 239
- MESSAGE
The error bit in the CS80 hardware was set, which indicates the device has had power re-applied or the heads have re-loaded.
- CAUSE
Device powered-on; head loaded.
- ACTION
None.
- 240
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the device needs to align its heads or run internal diagnostics (RELEASE REQUIRED).
- CAUSE
Device determined that automatic head alignment was required; performed same.
- ACTION
None.
- 241
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the diagnostic frontpanel on the device was accessed (RELEASE REQUIRED).
- CAUSE
Device allowed front-panel diagnostics to be executed.
- ACTION
Determine if front panel was accessed.
- 242
- MESSAGE
The error bit in the hardware status was set, which indicates that the operator unload button was pushed (RELEASE REQUIRED).
- CAUSE
Device allowed the operator to spin-down pack.
- ACTION
Either push button back in, or remove pack.
- 243
- MESSAGE
The error bit in the hardware status was set, which indicates a HARDWARE FAULT detected by internal diagnostics.
- CAUSE
Device diagnostics detected hardware problem.
- ACTION
Call your support representative.
- 244
- MESSAGE
The error bit in the CS80 hardware status is set, which indicates that a HARDWARE FAULT occurred in the addressed unit of the device.
- CAUSE
Could be hardware problem, or a transient problem due to power-on.
- ACTION
Call your support representative.
- 245
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that a HARDWARE FAULT occurred in the device controller.
- CAUSE
Device hardware problem.
- ACTION
Call your support representative.
- 246
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that an error occurred during a transfer of data between 2 units in the device (COPY DATA CS80 Command only).
- CAUSE
This should never occur as this feature is not supported.
- ACTION
Call your support representative.
- 247
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates the execution phase length is not as expected. A REJECT error occurred; could be cabling.
- CAUSE
CS80 transaction was incorrect; could be cabling.
- ACTION
Verify that cabling is correct and call your support representative.
- 248
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the CS80 Command bytes were out-of-sequence. A REJECT error occurred; could be cabling.
- CAUSE
CS80 transaction was incorrect; could be cabling.
- ACTION
Verify that cabling is correct and call your support representative.
- 249
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the parameter field of the CS80 Command is invalid. A REJECT error occurred; could be cabling.
- CAUSE
CS80 transaction was incorrect.
- ACTION
Verify that cabling is correct and call your support representative.
- 250
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the value in the PARAMETERS of the CS80 Command is too large. A REJECT error occurred; could be cabling.
- CAUSE
CS80 transaction was incorrect.
- ACTION
Verify that cabling is correct and call your support representative.
- 251
- MESSAGE
The error bit in the CS80 hardware status is set, which indicates that the value in the ADDRESS field in the CS80 Command is illegal. A REJECT error occurred; could be cabling.
- CAUSE
CS80 transaction was incorrect. The medium address range was exceeded.
- ACTION
Verify that cabling is correct and call your support representative.
- 252
- MESSAGE
The error bit was set in the CS80 hardware status was set, which indicates that CS80 Command Volume or Unit is illegal. A REJECT error occurred; could be cabling.
- CAUSE
CS80 protocol was incorrect. The device address range was exceeded.
- ACTION
Verify that cabling is correct and call your support representative.
- 253
- MESSAGE
The error bit in the CS80 hardware status was set, which indicates that the OPCODE of the CS80 Command bytes is invalid. A REJECT error occurred; could be
cabling.
- CAUSE
CS80 command bytes could be invalid.
- ACTION
Verify that cabling is correct and call your support representative.
- 254
- MESSAGE
The error bit in the CS80 hardware status is set, which indicates the PARITY of the CS80 Command bytes is bad. A REJECT error occurred; could be cabling.
- CAUSE
The device detected a parity error.
- ACTION
Verify that cabling is correct and call your support representative.
- 255
- MESSAGE
Immediate status returned, indicating the HOST targeted for this I/O did not respond.
- CAUSE
Fiber-optic disk detected lack of host communication.
- ACTION