HPlogo MPE XL Native Language Programmer's Guide: 900 Series HP 3000 Computer Systems > Appendix D Converting 7-Bit to 8-Bit Data

V7FF8CNV Operation

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Index

V7FF8CNV must be run on a terminal supported by VPLUS/XL, which supports display of all characters, enhancements, and alternate character sets used in the forms. If alternate character sets are used, the HP 2392, 2625, 2627, 2628, 2700, or 150 are recommended.

The V7FF8CNV procedure is:

  1. Configure your terminal type properly for 8-bit operation by using the settings recommended in System Startup, Configuration, and Shutdown Reference Manual (32650-90042).

  2. Run V7FF8CNV.PUB.SYS. Respond to prompts for the terminal group and the national substitution set.

  3. Press Next to begin going through the forms file.

  4. Press Enter after each screen until the end of the forms file is reached. Two exceptions are:

    1. Enter Y in Function key labels on each FORM MENU and the GLOBALS MENU to see and convert function key labels.

    2. On the field definition screen, if the processing specifications have converted data that you want to save, press the FIELD TOGGLE key then Enter to save that conversion.

    NOTE: If you try to redisplay a screen that has already been converted and this conversion has been saved by pressing Enter, a message Form contains 8 bit data is displayed. Do not press Enter again, but continue on through the forms file.

  5. Compile your forms file as usual.

These conversion utilities are designed to be used once only to update existing data to 8-bit compatibility.

Feedback to webmaster