This section describes the AS/400 configuration parameters that must
be specified in order for the AS/400 to communicate with SNA IMF on
the HP 3000.
Display Line Description |
 |
This portion of the AS/400 configuration describes the connection
between the AS/400 and the HP 3000.
- ROLE
(Data link role) Must be
*PRI (data link role for the AS/400).
- MAXFRAME
(Maximum frame size) Must match the MAX
DATA value configured on the HP 3000 SNA Node
Configuration: PU Data screen.
- LINESPEED
(Line speed) Must match the Transmission
Speed value configured on the HP 3000 SNA Node
Configuration: SDLC Link Data screen.
Display Controller Description |
 |
This portion of the AS/400 configuration describes the HP 3000 as a
3274 Cluster Controller.
- EXCHID
(Exchange identifier) Must match the ID
BLK and ID NUM values
configured on the HP 3000 SNA Node Configuration: PU Data screen for
dial-up lines.
- STNADR
(Station address) Must match the Station
ID value configured on the HP 3000 SNA Node
Configuration: SDLC Link Data screen.
Display Device Description |
 |
This portion of the AS/400 configuration describes the terminals
connected to the HP 3000.
- DEVD
(Device description) Must match the LU name
values configured on the HP 3000 SNA Node
Configuration: LU Data screen and in the SNA IMF Configuration:
Security Class Data screen.
- TYPE
(Device type) Must be
3277 for display terminals.