Global POWER Parameters |  |
Note that the global parameters
and subparameters described below have special
implications for the SNA NRJE workstation definitions. - BLOCKGP=n
The
block group size
for data files. Specify this parameter for FBA devices
only. Recommended value: 0 Default: 0 - COPYSEP=YES/NO
Specifies
whether separator pages/cards are produced between each copy of the
output. Recommended value:
YES Default: YES - DBLK=n
The
block size of data
file records and the size of each data buffer. If this parameter is
omitted or set to zero, VSE/POWER chooses the appropriate block
size. Range: 548-2008 Recommended value: 0 Default: 0 - JLOG=YES/NO
Specifies
whether job information messages will be logged on the system console. Recommended value: YES Default: YES - JSEP=(n,m)
The
number of separator
pages (n) and
separator cards (m)
to be included in the output to separate jobs. Range:
0-9 Recommended value: (1,1) Default: (0,0) - NTFYMSG=nnn
The
number of
messages to be kept in the notify queue. Range:
1-999 Recommended value: 64 - PAUSE=YES/NO
Specifies
whether the punch
writer task will wait before a job entry is punched. Recommended value: NO Default: NO - PRI=n
If
a priority is not specified on the
* $ $ JOB statement, the priority will default
to the value specified here. Range:
1-9 Default: 3 - RBS=(n,m)
The
number of pages and
cards to be processed before segmentation happens. Range: 1-999999 Recommended
value: (0,0) Default: (0,0), which means no
segmentation. - RJEBSC=YES/NO
Specifies
whether RJEBSC
code should be loaded. If no BSC nodes exist, specify
NO. Recommended value:
NO Default: YES - SNA=(,,POWER)
The
host job entry subsystem
VTAM expects. - STDCARD=(n,m)
The
number of job
entry cards that can be punched before a warning message is issued.
0 means no warning messages will be
sent. Range: 1-999999 Recommended
value: (0,0) Default: (0,0) - STDLINE=(n,m)
The
number of
records that can be printed before a warning message is issued.
0 means no warning messages will be
sent. Range: 1-999999 Recommended value: (0,0) Default: (0,0)
POWER Macro and Parameters |  |
- CMPACT=name
Do not specify this
parameter
Hewlett-Packard does not support compaction. - CONSOLE=YES
Specifies
whether
outbound data will be interrupted for messages to the remote
operator. This parameter can be specified only if the workstation
has a line printer in addition to a terminal console. - LSTROUT
The
default
destination for output from jobs submitted by this remote
workstation. If this parameter is omitted, the output will be sent
to the device specified by the value of the
REMOTE parameter (described below). - LU=name
Do not specify this
parameter
- PSWRD=password
The
password for the
remote station being defined. - PUNROUT
The
default
destination for punch output from jobs submitted by this remote
workstation. If this parameter is omitted, the output will be sent
to the device specified by the value of the
REMOTE parameter (described below). - REMOTE=nnn
The
remote
identifier. SNA remote identifiers must be higher than BSC
identifiers. Range: 1-200 - SESSLIM=6
The
maximum
number of sessions that can be logged on at this workstation. Default: 1 - TYPE=LUT1
The
type of terminal
to be supported. - XLATE=NO
Specifies
whether host