This section covers remote system configuration requirements for the following MPE/iX SNA products: This section presents the requirements for: ACF/NCP and ACF/VTAM for switched and non-switched lines NCP Token-Ring Interconnection (NTRI) X.25 NCP Packet Switching Interface (NPSI) logmode table parameters.
ACF/NCP and ACF/VTAM Requirements |  |
The ACF/VTAM start parameters refer to the table and buffer size definitions that ACF/VTAM uses to configure the resource requirements for the network. Because start parameters apply to the entire VTAM domain and are not specific to the remote node, HP does not make any suggestions. HP does recommend that the ACF/VTAM system programmer review the defined values and make any adjustments for additional requirements put on the system. The tables in this section contain the parameters that HP allows for its MPE/iX SNA products. Operands and values that you must specify are noted. The tables also contain other operands that are allowed. For operand definitions, refer to the section Parameter Definitions at the end of this chapter, or to the appropriate NCP or VTAM manual for the remote system.  |  |  |  |  | WARNING! The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis. |  |  |  |  |
For MPE/iX SNA products, more than one PU may be defined for an HP 3000. A maximum of eight PUs can be defined for each HP 3000 with SDLC links. Multiple PUs can be defined for each HP 3000 SNA Token Ring Link. The number of PUs defined depends upon the number of SNA Link products installed. A maximum of 255 LUs can be configured for each HP 3000 PU. For SNA NRJE/iX, it is recommended that at least three LUs be defined. SNA IMF can support a maximum of 64 LUs. The LU 6.2 products can start a maximum of eight LUs. See the MPE/iX SNA product documentation for more information on configuration requirements. Tables 1-9 and 1-10 define the parameters necessary to connect MPE/iX SNA products to a switched line. Any values listed that are not required are given as examples. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information. Table 1-9 MPE/iX SNA Products: NCP/VTAM Switched Line Operands and Values | Comments |
---|
LUDRPOOL macro | | NUMTYPE2=n | Required by all MPE/iX SNA products. | GROUP macro | | DIAL=YES | Required by all SNA products. | LNCTL=SDLC | Required by all MPE/iX SNA products. | REPLYTO | | TEXTTO | | TYPE=NCP | Required by all MPE/iX SNA products. | LINE macro | | ADDRESS=line addr | Required by all MPE/iX SNA products. | SPEED=rate | Required by all MPE/iX SNA products. | ANSWER=ON | | CALL=IN | Required by all MPE/iX SNA products. | CLOCKNG=EXT | Required by all MPE/iX SNA products. | DATRATE | | DUPLEX | | ETRATIO | | HDXSP | | INTPRI | | LPDATS | | MAXPU=1 | Required by all MPE/iX SNA products. | NRZI=YES | Allowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 API/iX, and HP SNADS/iX. | PAUSE | | POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. Invalid for ACF/NCP version 1, release 3, and later versions. | RETRIES=7 | | RING | | SPDSEL | | TRANSFER | | OWNER | |
Table 1-10 MPE/iX SNA Products: VTAMLST Switched Major Node Operands and Values | Comments |
---|
VBUILD macro | | | | TYPE=SWNET | Required by all MPE/iX SNA products. | | | PU macro | | | | puname PU | Required by all MPE/iX SNA products. | ADDR=n | Required by all MPE/iX SNA products. | ANS | Required by all MPE/iX SNA products. | IDBLK=023 | Required for SNA IMF/iX, SNA NRJE/iX, LU 6.2 API/iX, HP SNADS/iX, SNA DHCF/iX. | IDNUM=n | Required by all MPE/iX SNA products. | DISCNT=NO | | ISTATUS | | MAXLU | | PUTYPE=2 | Required by all MPE/iX SNA products. | SRT | | XID=YES | Required for PU type 2.1 (T2.1). | LU macro | | luname LU | Required by all MPE/iX SNA products. | LOCADDR=n | Required by all MPE/iX SNA products. Set to 0 for independent LUs. | BATCH=YES | Recommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later. | DLOGMOD | Do not specify for SNA DHCF/iX. | ISTATUS | | MODETAB=HPMODTAB | Do not specify for SNA DHCF/iX. | PACING=0 | Recommended for SNA IMF/iX. | SSCPFM=FSS | Required for LU 6.2 API/iX, SNA NRJE/iX, HP SNADS/iX, and SNA DHCF/iX. | SSCPFM=USSSCS | Required for SNA IMF/iX. | VPACING=0 | Recommended for SNA IMF/iX keyboards and displays. | USSTAB | Must be specified for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 products. | LOGAPPL | Can be used with SNA IMF/iX only. Do not specify for SNA NRJE/iX, or SNA DHCF/iX. |
Table 1-11 defines the parameters necessary to connect MPE/iX SNA products to a leased (non-switched) line. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information. Table 1-11 MPE/iX SNA Products: NCP/VTAM Non-Switched Line Operands and Values | Comments |
---|
GROUP macro | | | | DIAL=NO | Required by all MPE/iX SNA products. | LNCTL=SDLC | Required by all MPE/iX SNA products. | REPLYTO | | TEXTTO | | TYPE=NCP | Required by all MPE/iX SNA products. | | | LINE macro | | | | ADDRESS=line addr | Required by all MPE/iX SNA products. | SPEED=rate | Required by all MPE/iX SNA products. | CLOCKNG=EXT | Required by all MPE/iX SNA products. | DATRATE | | DUPLEX | | ETRATIO | | HDXSP | | INTPRI | | LPDATS | | MAXPU | | NRZI=YES | Allowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 API/iX, and HP SNADS/iX. | PAUSE | | POLLED=YES | Required for ACF/NCP ver. 1, rel. 1 or 2. Invalid for ACF/NCP ver. 1, rel. 3, and later versions. | | RETRIES | | | SERVLIM | | | SPDSEL | | | TRANSFER | | | OWNER | | | SERVICE macro | | | | | | ORDER | MAXLIST | | | | | PU macro | | | | | | puname PU | Required by all MPE/iX SNA products. | | ADDR=n | Required by all MPE/iX SNA products. | | ANS | | | DISCNT=NO | | | IRETRY | | | ISTATUS | | | MAXDATA=265 or | | | MAXDATA=521 | Required by all MPE/iX SNA products. | | MAXOUT=7 | PASSLIM=7 | | PUTYPE=2 | Required by all MPE/iX SNA products. | | RETRIES=7 | | | SRT | | | XID=YES | Required for type 2.1 node. | | LU macro | | | | | | luname LU | Required by all MPE/iX SNA products. | | LOCADDR=n | Required by all MPE/iX SNA products. Set to 0 for independent LUs. | | BATCH=YES | Recommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later. | | DLOGMOD | Do not specify for SNA DHCF/iX. | | ISTATUS | | | MODETAB=HPMODTAB | Do not specify for SNA DHCF/iX. | | PACING=0 | Recommended for SNA IMF/iX keyboards and displays. | | SSCPFM=FSS | Required for LU 6.2 API/iX, HP SNADS/iX, SNA NRJE/iX, and SNA DHCF/iX. | | SSCPFM=USSSCS | Required for SNA IMF/iX. | | VPACING=0 | Recommended for SNA IMF/iX keyboards and displays. | | USSTAB | Must be specified for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 products. | | LOGAPPL | Can be used with SNA IMF/iX only. Do not specify for SNA NRJE/iX, or LU 6.2 products. | |
X.25 NPSI Requirements |  |
This section defines the X.25 Network Control Program Packet Switching Interface (NPSI) parameters that are necessary for a successful connection between a host and MPE/iX SNA products. The ACF/VTAM start parameters refer to the table and buffer size definitions that ACF/VTAM uses to configure the resource requirements for the network. Because start parameters apply to the whole network and are not specific to the remote node, HP does not make any suggestions. HP does recommend that the ACF/VTAM system programmer review the defined values and make any adjustments for additional requirements put on the system. The tables in this section contain the parameters that HP allows for its MPE/iX SNA products. Operands and values that you must specify are noted. The tables also contain other operands that are allowed. For operand definitions, refer to the section Parameter Definitions at the end of this chapter, or to the appropriate NCP or VTAM manual for the remote system.  |  |  |  |  | WARNING! The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis. |  |  |  |  |
Table 1-15 defines the NPSI parameters that are necessary to connect to a PVC. See the Parameter Descriptions at the end of this chapter or refer to the NPSI manual for the remote system for more information. Table 1-15 MPE/iX SNA Products: PVC NPSI Parameters Operands and Values | Comments |
---|
| | | | | | | Required by all MPE/iX SNA products. | | | | Required by all MPE/iX SNA products. | | | | | | | | | | | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | | | | | | | Required by all MPE/iX SNA products. | | | | | | | | | | | | | | Required by all MPE/iX SNA products. | | | | | | | | | | | | Required by all MPE/iX SNA products. | | | | |
There are two methods that can be used to define an SVC: Use the X25.LINE macro, the X25.PU macro, and the Switched Major Node parameters for SVCs. Use the X25.VC macro and the Switched Major Node parameters for SVCs.
The method chosen depends upon the remote system. See the Parameter Descriptions at the end of this chapter or refer to the NPSI manual for the remote system for more information. Table 1-16 defines the NPSI parameters that are necessary to connect to an SVC. Table 1-17 defines the Switched Major Node parameters for SVCs. For MPE/iX SNA products, more than one PU may be defined for an HP 3000 node. A maximum of eight PUs can be defined for each HP 3000 node. The number of PUs defined depends upon the number of SNA Link products installed. A maximum of 64 LUs can be configured for each HP 3000 PU. For SNA NRJE/V, it is recommended that at least three LUs be defined. SNA IMF can support a maximum of 64 LUs. The LU 6.2 products can start a maximum of eight LUs. See the MPE/V SNA product documentation for more information on configuration requirements. Table 1-16 MPE/iX SNA Products: SVC NPSI Parameters Operands and Values | Comments |
---|
| | | | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | | | | | | | | | | | | | | | | | | | | | Required by all MPE/iX SNA products. | | | | | | | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | | | | | | | | | | | | | |
Table 1-17 MPE/iX SNA Products: SVC Switched Major Node Operands and Values | Comments |
---|
| | | | | Required by all MPE/iX SNA products. | | | | | | | | Required by all MPE/iX SNA products. | | | | Required for LU 6.2 API/iX, SNA NRJE/iX, and HP SNADS/iX. | | Required for SNA IMF/iX and SNA DHCF/iX IBM 3274 emulation. | | Required for SNA IMF/iX and SNA DHCF/iX IBM 3276 emulation. | | Required by all MPE/iX SNA products. | | | | | | | | | | | | | | Required by all MPE/iX SNA products. | | | | | | | | | | | | | | | | | | Required by all MPE/iX SNA products. | | | | | | | | | | Required by all MPE/iX SNA products. | | Required by all MPE/iX SNA products. | | Recommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later. | | Do not specify for SNA DHCF/iX. | | | | Do not specify for SNA DHCF/iX. | | Specify for SNA IMF/iX. | | Required by LU 6.2 API/iX, HP SNADS/iX, and SNA NRJE/iX. | | Required by SNA IMF/iX and SNA DHCF/iX. | | Recommended for SNA IMF/iX keyboards and displays. | | Valid for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX or LU 6.2 products. | | Valid for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX or LU 6.2 products. |
Logmode Table Requirements |  |
The Logmode table definitions determine the operating characteristics of the session with a host LU—the bind parameters. The tables in this section define the Logmode table parameters necessary for MPE/iX SNA products. Tables 1-18, 1-19, and 1-20 contain Logmode table parameters required for SNA NRJE/iX for the JES2, JES3, and POWER job entry subsystems. Table 1-21 contains the Logmode table parameters required for SNA IMF/iX. Table 1-22 contains the Logmode table parameters required for SNA DHCF/iX. Table 1-23 contains the Logmode table parameters for non-SNA devices connected to HCF. Table 1-24 contains the Logmode table parameters required for the LU 6.2 products, LU 6.2 API/iX and HP SNADS/iX. Table 1-18 SNA NRJE/iX: JES2 Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | Required value. | | | | | | Suggested value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | Suggested value. | | | Required value. | [1] | | |
Table 1-19 SNA NRJE/iX: JES3 Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | Required value. | | | Suggested value. | | | Required value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | Required value. | [1] | | |
Table 1-20 SNA NRJE/iX: POWER Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | | | | Required value. | | | Suggested value. | | | Required value. | | | Required value. | | | Suggested value. | | | Suggested value. | | | Required value. | [1] | | |
Table 1-21 SNA IMF/iX: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | for LU.T1 for LU.T2 with 1920 size screen for LU.T2 with 480 size screen for LU.T2 with 3440 size screen for LU.T3 | Suggested value. | | | Suggested value. | | | Required value. | | Printer (LU.T1): Terminal (LU.T2) and screen size of 1920 (24 x 80): Terminal (LU.T2) and screen size of 480 (12 x 40): Terminal (LU.T2) and screen size of 3440 (43 x 80): Printer (LU.T3): | Suggested value. | | Must be 8989 or less. -LU.T1 Printer -LU.T2 Terminal | Suggested value. | | (LU.T1/T3 printer), , or (LU.T2 display station) | Required value. | | -LU.T1 and LU.T3 printers -LU.T2 terminals | Suggested value. | | | Suggested value. | | | Required value. | [1] | | |
 |  |  |  |  | NOTE: Table 1-22 shows the logmode definitions for IBM 3270 terminals. The logmode entries defined for HP 3000 LUs are not used with SNA DHCF/iX. |  |  |  |  |
Table 1-22 SNA DHCF/iX: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | DHCF1920 for 1920 size screen | Suggested values. | | DHCF2560 for 2560 size screen | may be used | | DHCF3440 for 3440 size screen | for Model 2 devices. | | | Required value. | | Screen size of 1920 (24 x 80): Screen size of 2560 (32 x 80): Screen size of 3440 (43 x 80): | Suggested values. | | | Suggested value. | | | Required value. | | | Required value. | [1] | | |
Table 1-23 Non-SNA HCF Devices: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Required value. | | | Required value. | | | , the standard IBM-supplied logmode entry for non-SNA or BSC Model 2 devices, may be used. | | | Required value. | | Screen size of 1920: | Suggested value. | | | Suggested value. | | | Required value. | | | Required value. | [1] | | |
Table 1-24 MPE/iX LU 6.2 Products: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
| | Suggested value. | | | Suggested value. | | for LU 6.2 API/iX for HP SNADS/iX | Suggested value. | | | Suggested value. | | | Suggested value. |
 |  |  |  |  | NOTE: The values in table 1-24 are for node type 2.0 (T2.0) only. For T2.1 LUs (that is, independent LUs), the actual logmode value is not important, as long as the logmode is a valid one. |  |  |  |  |
|