 |
» |
|
|
|
This section covers remote system configuration requirements for the
following MPE/V SNA products: This section presents the requirements for ACF/NCP and ACF/VTAM for
switched and non-switched lines and logmode table parameters. ACF/NCP and ACF/VTAM Requirements |  |
The ACF/VTAM start parameters refer to the table and buffer size
definitions that ACF/VTAM uses to configure the resource
requirements for the network. Because start parameters apply to the
entire VTAM domain and are not specific to the remote node, HP does
not make any suggestions. HP does recommend that the ACF/VTAM system
programmer review the defined values and make any adjustments for
additional requirements put on the system. The tables in this section contain the parameters that HP allows for
its MPE/V SNA products. Operands and values that you must specify
are noted. The tables also contain other operands that are allowed.
For operand definitions, refer to the section Parameter
Descriptions at the end of this chapter, or to the appropriate NCP
or VTAM manual for the remote system.  |  |  |  |  | WARNING! The HP SNA products are emulations of IBM products. Thus, some
parameters will need particular values based on the requirements of
the HP products. Code these as specified or results are
unpredictable. Operands not listed are not allowed in the HP SNA
services definitions and therefore are not supported. Any time spent
solving problems related to incorrect configuration of the host is
billable to the customer on a time and materials basis. |  |  |  |  |
For MPE/V SNA products, more than one PU (Physical Unit) may be defined for an HP
3000 node. A maximum of eight PUs can be defined for each HP 3000
node. The number of PUs defined depends upon the number of SNA Link
products installed. A maximum of 64 LUs (Logical Units) can be configured for each HP 3000 PU. For
SNA NRJE/V, it is recommended that at least three LUs be defined. SNA
IMF can support a maximum of 64 LUs. The LU 6.2 products can start a
maximum of eight LUs. See the MPE/V SNA product documentation for
more information on configuration requirements. Tables 1-1 and 1-2 define the parameters necessary to connect MPE/V
SNA products to a switched line. Any values listed that are not
required are given as examples. See Parameter Descriptions at
the end of this chapter or refer to the appropriate NCP or VTAM
manual for the remote system for more information. Table 1-1 MPE/V Products: NCP/VTAM Switched Line Operands and Values | Comments |
---|
LUDRPOOL macro | | | | NUMTYPE2=n | Required by all MPE/V SNA products. | | | GROUP macro | | | | DIAL=YES | Required by all MPE/V SNA products. | LNCTL=SDLC | Required by all MPE/V SNA products. | REPLYTO | | TEXTTO | | TYPE=NCP | Required by all MPE/V SNA products. | | | LINE macro | | | | ADDRESS=line addr | Required by all MPE/V SNA products. | SPEED=rate | Required by all MPE/V SNA products. | ANSWER=ON | Required by all MPE/V SNA products. | CALL=IN | Required by all MPE/V SNA products. | CLOCKNG=EXT | Required by all MPE/V SNA products. | DATRATE | | DUPLEX | | ETRATIO | | HDXSP | | INTPRI | | LPDATS | | MAXPU=1 | Required by all MPE/V SNA products. | NRZI=NO | Required by all MPE/V SNA products. | PAUSE | | POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. Invalid for ACF/NCP version 1, release 3, and later versions. | RETRIES=7 | | RING | | SPDSEL | | TRANSFER | | OWNER | |
Table 1-2 MPE/V Products: VTAMLST Switched Major Node Operands and Values | Comments |
---|
VBUILD macro | | | | TYPE=SWNET | Required by all MPE/V SNA products. | | | PU macro | | | | puname PU | Required by all MPE/V SNA products. | ADDR=n | Required by all MPE/V SNA products. | ANS | Required by all MPE/V SNA products. | IDBLK=023 | Required for LU 6.2 API/V, LU 6.2 Base/V, SNA IMF/V,
and SNA NRJE/V. | IDNUM=n | Required by all MPE/V SNA products. | DISCNT=NO | | ISTATUS | | MAXLU | | PUTYPE=2 | Required by all MPE/V SNA products. | SRT | | XID=YES | Required for node type 2.1 (T2.1). | | | LU macro | | | | luname LU | Required by all MPE/V SNA products. | LOCADDR=n | Required by all MPE/V SNA products. Set to 0 for independent LUs. | BATCH=YES | Recommended for SNA NRJE/V on applicable versions of
ACF/NCP. This parameter is not supported for ACF/NCP version 5 or
later. | DLOGMOD | | ISTATUS | | MODETAB=HPMODTAB | | PACING=0 | Recommended for SNA IMF/V | SSCPFM=FSS | Required for LU 6.2 API/V, LU 6.2 Base/V, and SNA NRJE/V. | SSCPFM=USSSCS | Required for SNA IMF/V. | VPACING=0 | Recommended for SNA IMF/V keyboards and displays. | USSTAB | Must be specified for SNA IMF/V only. Do not specify
for SNA NRJE/V or LU 6.2 products. | LOGAPPL | Can be used with SNA IMF/V only. Do not specify for SNA NRJE/V. |
Table 1-3 defines the parameters necessary to connect MPE/V SNA products
to a leased (non-switched) line. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual
for the remote system for more information. Table 1-3 MPE/V Products: NCP/VTAM Non-Switched Line Operands and Values | Comments |
---|
GROUP macro | | | | DIAL=NO | Required by all MPE/V SNA products. | LNCTL=SDLC | Required by all MPE/V SNA products. | REPLYTO | | TEXTTO | | TYPE=NCP | Required by all MPE/V SNA products. | | | LINE macro | | | | ADDRESS=line addr | Required by all MPE/V SNA products. | SPEED=rate | Required by all MPE/V SNA products. | CLOCKNG=EXT | Required by all MPE/V SNA products. | DATRATE | | DUPLEX | | ETRATIO | | HDXSP | | INTPRI | | LPDATS | | MAXPU | | NRZI=NO | Required for SNA NRJE/V, SNA IMF/V, LU 6.2 Base/V, and
LU 6.2 API/V. | PAUSE | | POLLED=YES | Required for ACF/NCP version 1, release 1 and 2. Invalid for ACF/NCP version 1, release 3, and later versions. | RETRIES | | SERVLIM | | SPDSEL | | TRANSFER | | OWNER | | SERVICE macro | | | | ORDER | | MAXLIST | | | | PU macro | | | | puname PU | Required by all MPE/V SNA products. | ADDR=n | Required by all MPE/V SNA products. | ANS | | DISCNT=NO | | IRETRY | | ISTATUS | | MAXDATA=265 | Required by all MPE/V SNA products. | or MAXDATA=521 | | MAXOUT=7 | | PASSLIM=7 | | PUTYPE=2 | Required by all MPE/V SNA products. | RETRIES=7 | | SRT | | XID=YES | Required for type 2.1 node. | | | LU macro | | | | luname LU | Required by all MPE/V SNA products. | LOCADDR=n | Required by all MPE/V SNA products. Set to 0 for independent
LUs. | BATCH=YES | Recommended for SNA NRJE/V on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later. | DLOGMOD | | ISTATUS | | MODETAB=HPMODTAB | | PACING=0 | Recommended for SNA IMF/V keyboards and displays. | SSCPFM=FSS | Required for LU 6.2 API/V, LU 6.2 Base/V, and SNA NRJE/V. | SSCPFM=USSSCS | Required for SNA IMF/V. | VPACING=0 | Recommended for SNA IMF/V keyboards and displays. | USSTAB | Must be specified for SNA IMF/V only. Do not specify
for SNA NRJE/V or LU 6.2 products. | LOGAPPL | Can be used with SNA IMF/V only. Do not specify for
SNA NRJE/V. |
Logmode Table Requirements |  |
The Logmode table definitions determine the operating characteristics
of the session with a host LU—the bind parameters. The tables in
this section define the Logmode table parameters necessary for MPE/V
SNA products. Tables 1-4, 1-5, and 1-6 contain Logmode table parameters required
for SNA NRJE/V for the JES2, JES3, and POWER job entry subsystems. Table
1-7 contains the Logmode table parameters required for SNA IMF/V. Table
1-8 contains the Logmode table parameters required for the LU 6.2
products, LU 6.2 Base/V and LU 6.2 API/V. Table 1-4 SNA NRJE/V: JES2 Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
COMPROT | 7080 | Required value. | | | | FMPROF | 03 | Required value. | | | | LOGMODE | MODENRJE | Suggested value. | | | | PSNDPAC | 3 | Suggested value. | | | | PRIPROT | B1 or B3 | Required value. | | B3 | | | | | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | RUSIZES[1] | 8585 | Required value. | | | | SECPROT | A3 | Suggested value. | | | | SSNDPAC | 3 | Suggested value. | | | | SRCVPAC | 3 | Suggested value. | | | | TSPROF | 03 | Required value. | [1] | | |
Table 1-5 SNA NRJE/V: JES3 Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
COMPROT | 7080 | Required value. | | | | FMPROF | 03 | Required value. | | | | LOGMODE | MODENRJE | Suggested value. | | | | PSNDPAC | 3 | Suggested value. | | | | PRIPROT | A1, A3, B1, or B3 | Required value. | | | | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | RUSIZES[1] | 8686 | Required value. | | | | SECPROT | A1 or A3 | Required value. | | | | SSNDPAC | 3 | Suggested value. | | | | SRCVPAC | 3 | Suggested value. | | | | TSPROF | 03 | Required value. | [1] | | |
Table 1-6 SNA NRJE/V: POWER Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
COMPROT | 7080 | Required value. | | | | FMPROF | 03 | Required value. | | | | LOGMODE | MODENRJE | Suggested value. | | | | PSNDPAC | 3 | Suggested value. | | | | PRIPROT | A3 | Required value. | | B3 | | | | | PSERVIC | 01102000F100C00000010040 | Suggested value. | | | | RUSIZES[1] | 8585 | Required value. | | | | SECPROT | A1 | Required value. | | | | SSNDPAC | 3 | Suggested value. | | | | SRCVPAC | 3 | Suggested value. | | | | TSPROF | 03 | Required value. | [1] | | |
Table 1-7 SNA IMF/V: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
COMPROT | 3080 | Required value. | | | | FMPROF | 03 | Required value. | | | | | | | LOGMODE | IMFLU1 for LU.T1 | Suggested value. | | IMF1920 for LU.T2 with 1920 size screen | | | IMF480 for LU.T2 with 480 size screen | | | IMF3440 for LU.T2 with 3440 size screen | | | IMFLU3 for LU.T3 | | | | | PSNDPAC | 3 | Suggested value. | | | | PRIPROT | 11, 21, 31, A1, or B1 | Required value. | | | | PSERVIC | Printer (LU.T1): 01000000E100000000000000 | Suggested values. | | Terminal (LU.T2) and screen size of 1920: | | | 020000000000000000000200 | | | 020000000000185000007E00 | | | 020000000000185018507F00 | | | Terminal (LU.T2) and screen size of 480: | | | 020000000000000000000100 | | | 0200000000000C280C287E00 | | | 0200000000000C280C287F00 | | | Terminal (LU.T2) and screen size of 3440: | | | 0200000000002B5000007E00 | | | 02000000000018502B507E00 | | | Printer (LU.T3): 030000000000000000000200 | | RUSIZES[1] | Must be 8989 or less. | Suggested value. | | 8587-LU.T1 Printer | | | 8989-LU.T2 Terminal | | | | | SECPROT | 90 (LU.T1/T3 printer), A0, or B0 | Required value. | | (LU.T2 display station) | | | | | SSNDPAC | 3-LU.T1 and LU.T3 printers | | | 0-LU.T2 terminals | Suggested value. | | | | SRCVPAC | 3 | Suggested value. | TSPROF | 03 | Required value. | [1] | | |
Table 1-8 MPE/V LU 6.2: Logmode Table Required Parameters | Values (hexadecimal) | Comments |
---|
LOGMODE | MODE62 | Suggested value. | | | | PSERVIC | 000000000000000000000000 | Suggested value. | | | | PSNDPAC | 3 for LU 6.2 Base/V | Suggested value. | | 3 for LU 6.2 API/V | | | | | SSNDPAC | 0 | Suggested value. | | | | SRCVPAC | 0 | Suggested value. |
 |  |  |  |  | NOTE: The values in table 1-8 are for node type 2.0 (T2.0) only. For T2.1
LUs (that is, independent LUs), the actual logmode value is not
important, as long as the logmode is a valid one. |  |  |  |  |
|