 |
» |
|
|
|
Listed below are the messages that might occur when you validate
the NRJE configuration data. They are listed in numerical order
according to message number. Configuration file validation is discussed
in Chapter 3 “SNA NRJE Configuration” of this manual. MESSAGE: Configuration file corrupt.
Missing NRJE path. (NRJEVALERR 3) | CAUSE: The SNA NRJE path is missing from the configuration
file. ACTION: Create a new configuration file. |
MESSAGE: Configuration file corrupt.
Missing NRJE version. (NRJEVALERR 4) | CAUSE: No version stamp exists for the SNA NRJE path. ACTION: Create a new configuration file. |
MESSAGE: No configuration data exists
for NRJE subsystem. (NRJEVALWARN 5) | CAUSE: No data is configured for SNA NRJE. Note that
this is a warning message. ACTION: If you do not want SNA NRJE to be configured,
no action is necessary. If you want NRJE to be configured, you must
configure it before validating the configuration file again. |
MESSAGE: Path: !
Path name
not found. (NRJEVALERR 6) | CAUSE: The indicated path cannot be found in the configuration
file. ACTION: Ensure that the configuration data indicated in
the path (for example, wised or writername) is correctly configured. If it is, contact your HP
representative. |
MESSAGE: Path: !
No data found
in path record. (NRJEVALERR 7) | CAUSE: No data is in the record for the indicated path. ACTION: Ensure that data is configured for the indicated
path. If it is, contact your HP representative. |
MESSAGE: Path: !
Node "!" is
not configured under SNANODE screen. (NRJEVALERR 8) | CAUSE: NA node listed as a configured SNA NRJE node was
not configured as an SNA node. ACTION: Configure the indicated node as an SNA node on
the SNA Node Configuration screen. |
MESSAGE: Path: !
Logical device "!" is
not a valid NRJE reader. (NRJEVALERR 9) | CAUSE: The indicated ldev is invalid for the reader indicated
in the path. This usually happens when the ldev is already configured
for another subsystem. ACTION: Configure the correct ldev for the reader in the Logical Device field of the NRJE Configuration: Reader Data screen. Remember
that you should not configure the same reader ldev for workstations
that might be simultaneously active. |
MESSAGE: Path: !
Lookup table
is not configured under PAGE2 screen. (NRJEVALERR 10) | CAUSE: A formid is configured in the Output Destination field of the NRJE Configuration: Writer Data screen,
but a lookup table is not configured in the Formid Lookup Table File field of the NRJE Configuration: Workstation Data
Page 2 screen. ACTION: If you want a lookup table to be used, ensure
that a table is correctly configured on the NRJE Configuration:
Workstation Data Page 2 screen. If you do not want a lookup table
to be used, ensure that a formid is not configured on the NRJE Configuration:
Writer Data screen. |
MESSAGE: Path: !
LUs not validated.
Invalid SNAnode "!". (NRJEVALWARN 11) | CAUSE: This error is related to NRJEVALERR 8. If an invalid node name is specified on the NRJE
Configuration: Workstation Data screen, the LUs cannot be validated.
Note that this is a warning message. ACTION: Ensure that the indicated SNA node name is correct.
If it is, contact your HP representative. |
MESSAGE: Path: !
LU "!" is
not configured for SNAnode "!". (NRJEVALERR 12) | CAUSE: The indicated LU is not configured under the indicated
SNA node. ACTION: Ensure that the LU should be configured under
the SNA node. If it should be configured, configure it on the SNA
Configuration: PU and LU Data screen. |
MESSAGE: Path: !
No writers
are configured. (NRJEVALERR 13) | CAUSE: No writer is configured for the workstation indicated
in the path. ACTION: Configure at least one writer for the workstation
on the NRJE Configuration: Writer List screen. |
MESSAGE: Path: !
Logging subsystem "SUB0002" is
not configured. (NRJEVALERR 14) | CAUSE: The logging subsystem for SNA NRJE is not configured. ACTION: Configure the SNA NRJE logging subsystem (SUB0002)
on the Logging Configuration screen. |
MESSAGE: Path: !
Logging class "!" is
not configured. (NRJEVALERR 15) | CAUSE: The indicated SNA NRJE logging class is not configured. ACTION: Configure the indicated SNA NRJE logging class
on the Logging Configuration: Logging Classes screen. |
MESSAGE: Path: !
Unknown error
occurred while getting this path. (NRJEVALERR 16) | CAUSE: An unexpected error occurred while attempting
to obtain a path from the configuration file. This usually indicates
a problem with the validation procedure. ACTION: Contact your HP representative. |
MESSAGE: Path: !
Unknown error
occurred while reading the path data. (NRJEVALERR 17) | CAUSE: An unexpected error occurred while attempting
to read data from the configuration file. This usually indicates
a problem with the validation procedure. ACTION: Contact your HP representative. |
|