- 1
- Message
You must be logged on to MANAGER.SYS,INSTALL to set up for HPINSTAL. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #1) - Cause
You have either logged on as someone other than
MANAGER.SYS, or you are not in the INSTALL group. - Action
Log on as MANAGER.SYS,INSTALL
and execute SETUP.INSTUTIL. Contact the Response Center if further assistance
is required.
- 2
- Message
The group CD vuuff containing the HPINSTAL fileset could not be initialized. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #2) - Cause
SETUP was unable to access the group CD vuuff .SYS
on the compact disk (CD-ROM) containing the HPINSTAL file set. - Action
VSCLOSE the CD-ROM disk
labelled volume 1 (MPE_C-45.00_1). If SETUP is still unable to initialize the CD vuuff
.SYS group, contact the Response Center for further assistance.
- 3
- Message
The HPINSTAL data file, GRPNAMES, is non-existent. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #3) - Cause
Either the file is non-existent, or SETUP is accessing
the file in an invalid location. - Action
Use the LISTEQ
command to determine if a file equation exists. If it does exist,
reset GRPNAMES. If GRPNAMES still cannot be located, contact the
Response Center.
- 4
- Message
You must execute SETINIT to complete the SETUP. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #4) - Cause
An old accounting structure was encountered when
executing SETUP. SETUP cannot process successfully, therefore, you
will be required to execute an additional script, SETINIT. SETINIT
will purge the old accounting structure, then automatically execute
SETUP.INSTUTIL - Action
Execute the script, SETINIT.INSTALL. Contact the Response Center if further assistance
is required.
- 5
- Message
GRPNAMES has an invalid format. It is less than four records. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #5) - Cause
The GRPNAMES data file contains all group, account,
and volume set name entries to be created by SETUP.INSTUTIL for
use by HPINSTAL. The file has a specific format of a blank line,
an account name, the volume set name on which the account resides,
and the groups to be created in the account. - Action
Use the CI
command LISTEQ to determine if a file equation
exists. If it exists, reset GRPNAMES; then execute SETUP.INSTUTIL. If GRPNAMES still has an invalid format, contact
the Response Center for further assistance.
- 6
- Message
GRPNAMES has an invalid format for its first record. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #6) - Cause
The GRPNAMES data file has an invalid format. The
first record in the file should always be blank. - Action
Use the CI
command LISTEQ to determine if a file equation
exists. If it exists, reset GRPNAMES. If GRPNAMES still has an invalid format, contact
the Response Center for further assistance.
- 7
- Message
GRPNAMES has an invalid format. This account has no VOLUME ID. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #7) - Cause
The GRPNAMES data file on the compact disk has an
invalid format. The specific format of the file is a blank line,
followed by an account name, followed by the volume set name on
which the account resides, followed by the groups within the account. - Action
Use the CI command LISTEQ
to determine if a file equation exists. If it exists, reset GRPNAMES. If GRPNAMES still an invalid format, contact the
Response Center for further assistance.
- 8
- Message
GRPNAMES has no groups for the specified account. (SETERR #8) - Cause
The GRPNAMES data file has an invalid format. An
existing account in GRPNAMES has no associated groups. - Action
Use the CI command LISTEQ
to determine if a file equation exists. If it exists, reset GRPNAMES. Execute SETINIT.INSTUTIL. If GRPNAMES still an invalid format, contact the
Response Center.
- 9
- Message
A specified account was not successfully created. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #9) - Cause
One of the accounts in the GRPNAMES data file could
not be successfully created. - Action
Ensure that your log on,
MANAGER.SYS,INSTALL has all MPE capabilities. Ensure that no other process has accessed the account. If so, instruct the user to log off. Contact the Response Center if further assistance
is required.
- 10
- Message
Unable to successfully bind to the group group.account . SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #10) - Cause
SETUP was unable to create a group that was listed
in the GRPNAMES data file. - Action
Type the following command
to ensure that the group does not exist. Execute the SETINIT script to continue the SETUP.INSTUTIL.
If the group.account does not exist and you are unable to create
it, ensure that your MANAGER.SYS,INSTALL (user.account,group) has
full MPE capabilities. Contact the Response Center if further assistance
is required.
- 11
- Message
The file filename could not be successfully copied to INSTALL.SYS. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #11) - Cause
SETUP copies all files from the CD vuuff .SYS group
on the compact disk to INSTALL.SYS group for use by HPINSTAL. The
file set consists of HPINSTAL and all of its data files. This error
is a result of the inability to copy one of the HPINSTAL files from
the CD vuuff .SYS group into the INSTALL.SYS group. - Action
Perform the following command
to determine if the file exists and contains records. :LISTF FILENAME. CD VUUFF .SYS,2
|
Perform the following command to determine if the
file exists in INSTALL.SYS: :LISTF FILENAME .INSTALL.SYS,2
|
Ensure that the file is not busy. Then execute SETINIT.INSTALL. If SETUP still terminates abnormally, contact the
Response Center for further assistance.
- 12
- Message
The file filename could not be purged from the INSTALL.SYS group. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #12) - Cause
SETUP was unable to purge a file from the INSTALL.SYS
group prior to copying a newer version of the file from the CD vuuff
.SYS group. - Action
Perform the following command
to determine if the file is busy: :LISTF FILENAME .INSTALL.SYS,2
|
Determine the process accessing the file. Contact the Response Center if further assistance
is required.
- 13
- Message
Could not delete the temporary file LISTOUT or OUTF. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #13) - Cause
The temporary files, LISTOUT and OUTF, created by
the SETUP process exist and could not be deleted. - Action
Perform a listftemp,2 to
determine if the files are busy. Log on again as MANAGER.SYS,INSTALL. Contact the Response Center if further assistance
is required.
- 14
- Message
volname is not a valid volume set name (name must include MPE). SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #14) - Cause
The disk from which SETUP.INSTUTIL is executing
is not a valid Hewlett-Packard MPE formatted compact disk. - Action
VSCLOSE the volume set containing
SETUP.INSTUTIL. Insert a compact disk with the appropriate label. VSOPEN the volume_set_name. Bind to the new volume: ALTGROUP INSTUTIL.SYS;HOMEVS=VOLUME_SET. If you have no other compact disks, contact the
Response Center for further assistance.
- 15
- Message
volname is not a valid volume set name. ("_" must precede the VUF and vol ID). (SETERR #15) - Cause
The disk from which SETUP.INSTUTIL is executing
is not a valid Hewlett-Packard MPE-formatted compact disk. - Action
VSCLOSE the volume set containing
SETUP.INSTUTIL. Insert a compact disk with the appropriate label. VSOPEN the volume_set_name. Bind to the new volume: ALTGROUP INSTUTIL.SYS;HOMEVS=VOLUME_SET. If you have no other compact disks, contact the
Response Center for further assistance.
- 16
- Message
volname is not a valid volume set name because of the V.UU.FF. (SETERR #16) - Cause
The disk from which SETUP.INSTUTIL is executing
is not a valid Hewlett-Packard MPE-formatted compact disk. - Action
VSCLOSE the volume set containing
SETUP.INSTUTIL. Insert a compact disk with the appropriate label. VSOPEN the volume_set_name. Bind to the new volume: ALTGROUP INSTUTIL.SYS;HOMEVS=VOLUME_SET. If you have no other compact disks, contact the
Response Center for further assistance.
- 17
- Message
SETINIT will terminate. (SETERR #17) From the system console, VSCLOSE mpe_volsetname. If this a SCSI drive, run AVRSCSI.INSTALL dismount ldev to take the disk offline. - Cause
A CI error occurred during the SETINIT script while
attempting to VSCLOSE an open compact disk. - Action
The associated CI error
message is displayed. The disk can only be closed if no files on
the disk are being accessed. If the disk cannot be closed, determine
the files being used, kill any processes accessing the disk, then
execute SETINIT again. Contact the Response Center if further assistance
is required.
- 18
- Message
This disk is in an invalid state for this process. SETINIT will terminate. (SETERR #18) - Cause
This message occurs in two instances. Either SETINIT
is attempting to VSCLOSE a disk that is in an invalid state for
the process, or SETINIT is attempting to VSOPEN a disk that is in
an invalid state. - Action
Manually VSCLOSE/VSOPEN
the volume set from the system console. Contact the Response Center if further assistance
is required.
- 19
- Message
SETINIT will terminate. To continue, you must go to the system console and VSOPEN mpe_volsetname. If necessary, run AVRSCSI.INSTALL to put the volume set containing SETUP.INSTUTIL online. (SETERR #19) - Cause
SETINIT is attempting to VSOPEN a volume set that
is in the "LONER" state, but is unsuccessful. - Action
Go to the system console
and VSOPEN the volume set name. Contact the Response Center if further assistance
is required.
- 20
- Message
CD v.uu.ff.SYS has garbage in its last record. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #20) - Cause
The GRPNAMES data file is corrupted. - Action
Ensure the no file equation
exists for GRPNAMES. Contact the Response Center if further assistance
is required.
- 21
- Message
You must execute SETUP.INSTUTIL prior to executing SETINIT. (SETERR #21) - Cause
SETINIT uses a secondary CI script called OLDACCTS
to establish MPE release-dependent variables. This script is built
by SETUP.INSTUTIL, and is deleted by SETUP.INSTUTIL upon normal
termination. Therefore, SETUP.INSTUTIL must be executed first, and
it must fail prior to SETINIT. - Action
Ensure that the CD containing
the INSTUTIL.SYS group is online. From MANAGER.SYS,INSTALL, execute SETUP.INSTUTIL. If SETUP.INSTUTIL fails, execute SETINIT.INSTALL. Contact the Response Center if further assistance
is required.
- 22
- Message
Unable to set file equation for the file HPINSTAL.INSTALL. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #22) - Cause
SETUP.INSTUTIL forces the file HPINSTAL.INSTALL
onto LDEV 1 by setting a file equation prior to copying the file
from compact disk. However, SETUP.INSTUTIL failed when attempting
to set the file equation. - Action
Do a LISTEQ to determine
the file equations that have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 23
- Message
Unable to set file equation for the file HICAT000.INSTALL. Setup will terminate. Follow the instructions in your installation manual to continue. (SETERR #23) - Cause
SETUP.INSTUTIL forces the file HICAT000.INSTALL
onto LDEV 1 by setting a file equations prior to copying the file
from compact disk. However, SETUP.INSTUTIL failed when attempting
to set the file equation. - Action
Do a LISTEQ to determine
the file equations that have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 24
- Message
Unable to set file equation for the file PEXL.INSTALL. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #24) - Cause
SETUP.INSTUTIL forces the file PEXL.INSTALL onto
LDEV 1 by setting a file equations prior to copying the file from
compact disk. However, SETUP.INSTUTIL failed when attempting to
set the file equation. - Action
Do a LISTEQ to determine
the file equations that have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 25
- Message
PURGEGROUP command failed when attempting to purge the group PUB. curr_acct. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #25) - Cause
SETUP.INSTUTIL uses the data file GRPNAMES.CD vuuff
.SYS to determine the accounting structure on the compact disk set.
SETUP. INSTUTIL must purge the group PUB. curracct from the system
domain prior to binding to it on the CD. - Action
Ensure the group is not
busy. Contact the Response Center if further assistance
is required.
- 26
- Message
Unable to set file equation for OLDACCTS data file. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #26) - Cause
SETUP.INSTUTIL failed when attempting to set a file
equation for OLDACCTS. - Action
Do a LISTEQ to determine
which file equations have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 27
- Message
SETUP could not purge its old error log SETUPLOG. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #27) - Cause
A SETUPLOG existed from a previous execution of
SETUP.INSTUTIL, and it could not be purged. - Action
Ensure that the file is
not busy. Ensure that the file is not a temporary file. Contact the Response Center if further assistance
is required.
- 28
- Message
Unable to set file equation for log file, SETUPLOG. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #28) - Cause
SETUP.INSTUTIL failed when attempting to set a file
equation for SETUPLOG. - Action
Do a LISTEQ to determine
which file equations have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 29
- Message
SETUP could not purge its old data file, INITCIVR. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #29) - Cause
A INITCIVR existed from a previous execution of
SETUP.INSTUTIL, and it could not be purged. - Action
Ensure that the file is
not busy. Ensure that the file is not a temporary file. Contact the Response Center if further assistance
is required.
- 30
- Message
Unable to set file equation for data file, INITCIVR. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #30) - Cause
SETUP.INSTUTIL failed when attempting to set a file
equation for INITCIVR. - Action
Do a LISTEQ to determine
which file equations have been set. Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET @.) Contact the Response Center if further assistance
is required.
- 31
- Message
Unable to purge old initialization file, SETUPYES. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #31) - Cause
A SETUPYES existed from a previous execution of
SETUP.INSTUTIL, and it could not be purged. - Action
Ensure that the file is
not busy. Ensure that the file is not a temporary file. Contact the Response Center if further assistance
is required.
- 32
- Message
Unable to purge old initialization file, SETINIT. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #32) - Cause
A SETINIT existed from a previous execution of SETUP.INSTUTIL,
and it could not be purged. - Action
Ensure that the file is
not busy. Ensure that the file is not a temporary file. Contact the Response Center if further assistance
is required.
- 33
- Message
Failed to copy initialization file SETUPYES. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #33) - Cause
SETUP.INSTUTIL failed when attempting to copy SETUPYES.INSTUTIL
to SETUPYES.INSTALL. - Action
Ensure that the file SETUPYES.INSTUTIL
exists. Ensure that no file equation exists for SETUPYES.INSTALL. Purge SETUPYES.INSTALL in both the permanent and
temporary domains. Contact the Response Center if further assistance
is required.
- 34
- Message
Failed to copy initialization file SETINIT. SETUP will terminate. Follow the instructions in your installation manual to continue. (SETERR #34) - Cause
SETUP.INSTUTIL failed when attempting to copy SETINIT.INSTUTIL
to SETUPYES.INSTALL. - Action
Ensure that the file SETINIT.INSTUTIL
exists. Ensure that no file equation exists for SETUPYES.INSTALL. Purge SETINIT.INSTALL in both the permanent and
temporary domains. Contact the Response Center if further assistance
is required.
- 35
- 36
- Message
Unable to purge the account mpe_hpslt. (SETERR #36) - Cause
SETINIT failed when attempting to purge the account
mpe_hpslt. - Action
Ensure that no files are
open in the account. Purge the account from your terminal. Contact the Response Center if further assistance
is required.
- 37
- Message
Unable to purge the account mpe_hpupdate. (SETERR #37) - Cause
SETINIT failed when attempting to purge the account
mpe_hpupdate. - Action
Ensure that no files are
open in the account. Purge the account from your terminal. Contact the Response Center if further assistance
is required.
- 38
- Message
Unable to purge the group mpe_cdgroup. (SETERR #38) - Cause
SETINIT failed when attempting to purge the group
mpe_cdgroup .SYS. - Action
Ensure that no files are
open in the group. Purge the group from your terminal. Contact the Response Center if further assistance
is required.
- 39
- Message
MPE release-dependent CI variables could not be created. SETINIT will terminate. (SETERR #39) - Cause
SETINIT was unable to successfully execute the CI
script OLDACCTS to create the following MPE/iX release-dependent
variables: mpe_vol_1, mpe_vol_2, mpe_hpslt, mpe_hpupdate, and MPE_cdgroup.
SETINIT examines these variables to determine the MPE/iX software
release version contained on the CD-ROM disks. - Action
Record any error messages
preceding this message. Attempt to manually execute the OLDACCTS scripts
from your terminal. If the script fails again, the CI variable table
may be full. Delete user variables by entering DELETEVAR @ . Execute SETINIT.INSTAL again.
|