NAMEcfl — configure a logical unit (LUN) on a SCSI disk array SYNOPSIScfl
[-L
LUN_address]
[-a -clist
[,list
]
[-i]]
[-b
block_size]
[-clist
[,list
]]
[-d]
[-f
flag_word]
[-k
num_log_blocks]
[-l
sec_tenths]
[-n
num_log_blocks]
[-p
list]
[-r
RAID_level]
[-s
num_log_blocks]
[-t
reg|sub]
[-z
num_log_blocks]
device_file DESCRIPTIONcfl
sets configuration parameters, and changes the status
of a
LUN
on the
HP SCSI
disk array associated with
device_file. NOTE:
newarray,
a front-end program for
cfl,
is recommended for doing array configuration
(see
newarray(1M)). Options- -L LUN_address
Specifies which
SCSI
unit address to affect. - -a -c list [,list ] [ -i ]
list
is a comma-separated drive list
(cXiY
,cXiY
,...) describing
drives on
SCSI
channel
X,
and
SCSI ID
Y
(where
X
and
Y
are decimal numbers). Multiple
lists
are delimited by space characters. Add a
LUN
to the set of
LUNs known by the controller.
If this option is used,
the runstring must also contain a value for the
-c
parameter, and can contain values for all other applicable
parameters except
-d
(the delete
LUN
option). If only the
-c
parameter is supplied, a default
RAID-level 0 configuration
is created with the drives specified in the parameter list.
The user may thus specify all the
LUN
characteristics
in one line; create a default configuration and change a
few of the parameters to desired values in one line, or
create a default configuration and iteratively
change its parameters to the desired values. The
-i
option formats the newly added
LUN
after configuration.
If multiple
LUNs are to be added and configured, each
LUN
must
be formatted before any other LUNs can be added and configured. - -b block_size
Set the logical block size of the
LUN.
block_size
is specified in bytes. - -c list [,list2] device_file
Assign to the
LUN
a configuration table that describes which drives are associated with the
LUN
and specifies the order each drive appears in a data stripe.
One, or more tables can be assigned to each
LUN, depending on the
RAID
level. Each table can have a maximum of five drives. - -d
Delete the
LUN
from the set of
LUNs known by the controller. This option cannot be used simultaneously
with the
-a
option. - -f flag_word
Assign the desired hexadecimal values, given in
flag_word,
to the array's two
LUN
flag bytes.
The default
flag_word
is hex
0072.
User-changeable bits are in Mode Page 0x2b byte 25 (the lsb): bit 4,
which enables
AEN
polling when set; bit 5, which enables parity verification when set, and bit 6,
which enables writes with parity verification when set. - -k num_log_blocks
Set the reconstruction quantity in blocks. This
represents the number of blocks reconstructed in a single
reconstruction command. Reconstruction commands are issued
at an adjustable interval until the
LUN
is reconstructed (see the
-l
option). - -l sec_tenths
Set the reconstruction frequency, the interval between
successive reconstruction commands. It is expressed in tenths of
a second. - -n num_log_blocks
Set the number of logical blocks in the
LUN. - -p list
Create the
LUN's
disk bit map, which describes
the drives associated with the
LUN.
Either a configuration table or
a disk bit map, but not both, is required to configure a
LUN; use of
the configuration table is recommended. - -r raid_level
Set the
RAID
level of the
LUN; valid
RAID
levels are 0, 1, 3 and 5. - -s num_log_blocks
Set the number of blocks in a
LUN
segment, the part of a
data stripe residing on a single disk. - -t reg | sub
Set the
LUN
type, regular or sub-LUN.
A sub-LUN
is a
LUN
that can share its physical drive(s) with another
LUN; usually,
its data resides on more than one drive. Configurations involving
data striping or mirroring should use sub-LUNs. - -z num_log_blocks
Set the number of blocks in the first segment of the
LUN.
RETURN VALUEcfl
returns the following values:
- 0
Successful completion. - -1
Command failed (an error occurred).
DIAGNOSTICS AND ERRORSErrors can originate from problems with:
SCSI
(device level) communications
All error information is printed to stderr. Error messages generated by cfl:usage: cfl -L <LUN_addr> -a <-c ...> [-i] <special> add LUN
cfl -L <LUN_addr> -b <n> <special> set logical block size
cfl -L <LUN_addr> -c <<cXiY,... [cXiY,...]> | none> <special> build
config table(s)
cfl -L <LUN_addr> -d <special> delete LUN
cfl -L <LUN_addr> -f <n> <special> set LUN flags
cfl -L <LUN_addr> -k <n> <special> set reconstruction amt in
blocks
cfl -L <LUN_addr> -l <n> <special> set reconstruction frequency
cfl -L <LUN_addr> -n <n> <special> set number of blocks in LUN
cfl -L <LUN_addr> -p <cXiY,...> <special> build disk bit map
cfl -L <LUN_addr> -r <n> <special> set RAID level
cfl -L <LUN_addr> -s <n> <special> set segment size in blocks
cfl -L <LUN_addr> -t <reg | sub> <special> set LUN type
cfl -L <LUN_addr> -z <n> <special> set segment 0 size in blocks An error in command syntax has occurred. No valid tags were present,
or an illegal tag was encountered. Re-enter the command with all required
arguments. If a syntax error occurs in a runstring with a legal tag, only
the template for that tag will be displayed.
- cfl: Arg incompatible with other
One of the arguments is incompatible with another, for example, when the
-a
(add
LUN) and
-d
(delete
LUN) are both on the command line. - cfl: Arg out of range
One of the arguments is larger than its allowed maximum value
(or smaller than its allowed minimum value), or
is incorrect in form. Check the size, and form of each argument
and make appropriate corrections. - cfl: device busy
To ensure that
cfl
does not modify a disk array
that is being used by another process,
cfl
attempts to obtain exclusive access to the disk array.
If the disk array is already opened by another process
(for example, LVM — the Logical Volume Manager),
a
``device busy''
error message is returned by the driver.
To eliminate the
``device busy''
condition, determine what process has the device open.
In the case of LVM,
it is necessary to deactivate the volume group containing the array
before configuring the array (see
vgchange(1M)). - cfl: LUN does not exist
The addressed
LUN
is not known to the array
controller. Only the
-a
option can operate on an unconfigured
LUN.
The
-d
option ignores references unconfigured
LUNs (and does nothing with them). - cfl: LUN # too big
The
LUN
number, which is derived from the device special file name, is
out of range. - cfl: Multiple args of same type
An argument occurs more than once on the command line. - cfl: Not a disk array
The device being addressed did not identify itself as a
SCSI
disk array
product that is supported by
cfl. - cfl: Not a raw file
cfl
must be able to open the device file for raw access (the
character device file). - cfl: Transfer length error
The amount of data actually sent to or received from the device was
not the expected amount.
SCSI (device level) communication errors:Sense data associated with the failed operation is printed. Error messages generated by system calls:cfl
uses the following system calls:
malloc(),
free(),
stat(),
open(),
close(),
read(),
write(),
and
ioctl().
Documentation for these
HP-UX
system calls contains information about the specific error conditions
associated with each call.
cfl
does not alter the value of
errno.
The interpretation of
errno
for printing purposes is performed by the system utility
strerror(). EXAMPLESTo delete
LUN
5 associated with
/dev/rdsk/c2t0d0:
cfl -L 5 -d /dev/rdsk/c2t0d0 To add the
LUN
0 associated with
/dev/rdsk/c2t0d0,
which will have the following characteristics:
logical block size 512 bytes,
RAID
level of 5,
auto reconstruct disabled,
reconstruction amount of 64 blocks,
reconstruction frequency of .2 seconds,
segment size of 64 blocks,
type sub-LUN,
segment zero size of 1,
and drives with
SCSI ID
1 on channels 1 through 5,
to be striped in the channel order 3, 5, 1, 2 and 4:
cfl -L 0 -a -b 512 -r 5 -f 0072 -k 64 -l 2 -n 123456 -s 64
-t sub -z 1 -c c3i1,c5i1,c1i1,c2i1,c4i1 /dev/rdsk/c2t0d0 WARNINGChanging any configuration parameter except the reconstruction frequency and
reconstruction quantity puts the affected
LUN
in an unusable ("dead") state.
You must reformat the
LUN
before it can be used with the new configuration values.
Formatting a
LUN
destroys all of its user data. DEPENDENCIESThe HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems
running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running
HP-UX versions 9.0X and 10.0X. AUTHORcfl
was developed by HP.
|