HP Part Number: 5958-5824-2542
Published: Oct 15 1985
Notice
The information contained in this document is subject to change without notice.
HEWLETT-PACKARD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for
errors contained herein or for incidental or consequential damages in
connection with the furnishing, performance, or use of this material.
This document contains proprietary information which is protected by copyright.
All rights are reserved. Permission to copy all or part of this document is
granted provided that the copies are not made or distributed for direct
commercial advantage; that this copyright notice, and the title of the
publication and its date appear; and that notice is given that copying is by
permission of Hewlett-Packard Company. To copy otherwise, or to republish,
requires prior written consent of Hewlett-Packard Company.
Copyright © 1985 by HEWLETT-PACKARD COMPANY
Terminal Type 4
This terminal type is supported with device type 16 only on MPE IV and MPE V/P
ADCC and ATC ports. It is used for HP2600A or Datapoint 3300 keyboard display
terminals at (10,15,30,60,120,240 cps).
| Flow Control: |
XON/XOFF wth timer disabled |
| Block Mode: |
not supported |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo on, linefeed accepted during input data, linefeed character
replaces formfeed in output data, system response to a backspace is an
end-of-marker character, 7 databits recognized. |
| Printer Control: |
None. |
| Considerations: |
This terminal type is rarely seen as the devices requiring it are quite
archaic. If used on MPE V/E or above there is a delay protocol that has
been added which will cause the display output to pause for .3 seconds
at every linefeed. |
Terminal Type 6
This terminal type is supported with device type 16 on MPE IV and MPE V ATC,
ADCC and ATP ports. It is used for HP2762 A/B (General Electric terminet 300
or 1200), or Data Communications terminal model B at (10,15,30,120 cps) with
paper tape reader/punch, option 2. Note: this terminal must be equipped for
echoplex.
| Flow Control: |
XON/XOFF with timer disabled. On MPE V/E and above there is a delay
protocol of .3 seconds for line feeds and form feeds. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo on, linefeed accepted during input data, form feed allowed
in output data, system response to a backspace is a linefeed character.
7 databits recognized. A DC3 character is output after each linefeed. |
| Printer Control: |
none. |
| Considerations: |
Watch out for delay protocol for this termtype. On termtype 6 the ADCC
actually outputs 45 NUL's after a carriage return or linefeed at 240 cps. |
Terminal Type 9
This terminal type is supported with device type 16 on mpe IV and MPE V ATC,
ADCC and ATP ports. It is used for the old HP2615 Beehive Mini Bee. It is also
widely used for foreign terminals which do not use enq/ack flow control or block mode.
| Flow Control: |
XON/XOFF with timer disabled. On MPE V/E and above there is a delay
protocol of .3 seconds for linefeeds and formfeeds. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo on, line feed accepted during input data, formfeed allowed
in output data, no system response to a backspace, 7 databits recognized. |
| Printer Control: |
none. |
| Considerations: |
Because of the delay protocol used with V/E and above operating systems
this terminal type is infeasible for foreign terminals. The symptoms are
a very sluggish terminal (.3 seconds line feed delay). Terminal type 18
does not use this delay protocol and is generally recommended for foreign
terminal applications. |
Terminal Type 10
This terminal type is supported with device type 16 on all versions of MPE for any
asynchronous port. It is used for HP terminals and devices including the 264x, 262x
and 239x families of terminals as well as the HP 150. This terminal type is also
used on foreign terminals which emulate HP's enq/ack protocol and block mode data
transmission. These include the Direct 825 and 1025.
| Flow Control: |
ENQ/ACK with time out transmission after 10 seconds.
XON/XOFF with timer disabled. |
| Block Mode: |
Enabled for line and page block mode. Alert character is a DC2,
trigger character is a DC1. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo on, linefeed accepted as input data, no system response
to backspace, 7 databits recognized. |
| Printer Control: |
none. |
| Considerations: |
If a non HP terminal is configured with termtype 10 the computer will
send an ENQ character but the terminal will not respond so only 80
characters are printed every 10 seconds. |
Terminal Type 12
This terminal type is supported with device type 16 on all versions of MPE for
any asynchronous port. It is used for native language extended characters sets
on HP terminals over ATC ports and for the HP2645 Katakana/Roman data terminal.
The only difference between this terminal type and termtype 10 is that termtype
12 expects 8 data bits where termtype 10 expects 7.
| Flow Control: |
ENQ/ACK with time out retransmission after 10 seconds.
XON/XOFF with timer disabled. |
| Block Mode: |
Enabled for line and page block mode. Alert character is a DC2.
Trigger character is a DC1. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo on, linefeed accepted as input data, formfeed allowed in
output data, no system response to backspace, 8 databits with no parity. |
| Considerations: |
HP terminals on ATP ports or ADCC ports must be configured for parity=none,
chk parity=no and data bits=8 when used for NLS/3000 on
termtype 10. |
Terminal Type 13
This terminal type is supported with device type 16 on all versions of MPE for
any asynchronous port. It is used for message switching networks or communication
with other computers where echo is not desired. It is also common on a 2601A
printer although termtype 18 is recommended.
| Flow Control: |
XON/XOFF with timer disabled. |
| Block Mode: |
line and page block mode with alert character DC2 and trigger character DC1 |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
Initial echo off, linefeed accepted as input data, formfeed allowed in
output data, no system response to backspace, 7 data bits, none or
zeros parity. |
| Printer Control: |
none |
| Considerations: |
HP2601A and 26028 printers frequently use this termtype however the
block mode and echo are not needed and termtype 18 will work fine.
This terminal type is often used over Telnet and Tymnet networks where the
user would be charged for those echoed characters. |
Terminal Type 14
This terminal type is used by HP MTS terminals which use synchronous data
transmission over an INP. It will not work over any asynchronous controller
although it does have the same characteristics as termtype 10.
| Flow Control: |
ENQ/ACK with time out transmission after 10 seconds.
XON/XOFF with timer disabled. |
| Block Mode: |
enabled for line and page block mode. Alert character DC2,
trigger character DC1 |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
none |
| Considerations: |
Terminals running on MTS are the only devices using this terminal type.
MTS terminals conncected to a 2333a cluster controller will use
termtpe 10 however. |
Terminal Type 15 & 16
These terminal types are supported on MPE IV and MPE V over any asynchronous
control1er. They are grouped together because they are both used for the same
single device, the 2635 printing terminal. The difference being that terminal
type 15 is used for 8 bit data transmission needed for NLS/3000 or other
extended character sets.
| Flow Control: |
ENQ/ACK, XON/XOFF with timer disabled. |
| Block Mode: |
not supported |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, linefeed accepted during input data, linefeed replaces
formfeed in output data, system response to a backspace is an line feed
character, 7 data bits bits for termtype 16 and 8 data bits for terminal
type 15. |
| Considerations: |
As of MPE V/E Block Mode has been removed from termtype 15 and 16.
Terminals configured with this termtype that use block mode must be
reconfigured to a supported block mode termtype like 10 or 12. |
Terminal Type 18
This terminal type is supported with device types 16 & 32 on all versions of
MPE for any asynchronous port. It is used for all foreign terminals that do
not use ENQ/ACK and printers with less intelligent controllers. It is not
supported spooled.
| Flow Control: |
XON/XOFF with timer disabled. |
| Block Mode: |
not supported. |
| Read Trigger: |
NUL |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, linefeed accepted during input data, formfeed allowed
in output data, no system response to a backspace, 7 data bits bits recognized. |
| Printer Control: |
none |
| Considerations: |
This terminal type is considered the "plain vanilla" terminal type used
with foreign devices and some HP devices. Terminal type 18 is not supported
for spooled printers because no status checking is done for possible
printer problems. If a printer problem occurs status checking wi11 stop the
spooling process and print a message at the console indicating that that
there is some kind of problem with the printer. Printers requiring this
termtype do not have the firmware to respond to status checks. |
Terminal Type TTPCL18
This terminal type is supported with device type 32 on MPE V/E and above operating
systems which allow user defined terminal types created with the workstation
configurator. It is shipped on MPE V T-MIT and above installation tapes. It has
been designed to provide enhanced control for printers that do not use termtype 19
or 21. It also can be used for extended character printing as it uses 8 data bits.
| Flow Control: |
XON/XOFF with 60 second timer enabled upon receipt of each XOFF. If
an XON is not received in 60 seconds a message is displayed on the
console and the CPU continues to wait for the XON. |
| Block Mode: |
not supported. |
| Read Trigger: |
NUL |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in output data, linefeed accepted as
input data, no system response to backspace, 8 data bits no parity. |
| Printer Control: |
Printer initialization to hard reset, disable display functions mode
and turn on auto perf-skip. |
| Considerations: |
Because of the 60 second timer and the added printer initialization
this should be a desired terminal type for HP printers currently on
termtype 18. |
Terminal Type 19
This terminal type is supported with device type 32 on all versions of MPE
for any asynchronous port. It is used for HP spooled printers that have more
intelligent controllers including the 256X, 263X and 293X printer families.
| Flow Control: |
XON/XOFF with timer disabled. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in output data, linefeed accepted in
input data, no system response to a backspace, 7 data bits odd parity. |
| Printer Control: |
Printer initialization to disable display functions, enable HP terminal
mode, turn off underlining, set ROM1 to second character set, set ROM2
to primary character set, set pitch at 10.0, set line spacing at 6 lines
per inch, clear horizontal tabs, set right margin, set left margin,
slew 1 line at line feed, turn on auto perf-skip, disable char set
selection control. |
| Considerations: |
Termtype 19 sends a status request to the printer when the printer is
opened, at the end of every line and when the port receives an XOFF
character. This status request checks for printer online, paper and
transmission errors. If the printer does not reply within 10 seconds
a spoolee I/0 error is encountered and the printer will stop spooling.
If the printer is remote and a multiplexor is used, the status request
may not always return with in 10 seconds. Termtype 21 does not generate
a status request at the receipt of an XOFF. Instead a 60 second timer
is started and if an XON is not received in that time a "device not ready"
message is displayed and the spooler will continue to wait for the XON. |
Terminal Type TTPCL19
This terminal type is supported with device type 32 on MPE V/E and above
operating systems which allow user defined terminal types created with the
workstation configurator. It is shipped on MPE V T-MIT and above installation
tapes. It is used for HP direct connect and remote spooled printers such as the
256X and 293X printers. The difference between this termtype and termtype 19
is that this one contains less printer initialization. This makes it simpler
for the user or programmer to select desired printer settings.
| Flow Control: |
XON/XOFF with timer disabled |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in output data, linefeed accepted in
input data, no system response to backspace, 7 data bits odd parity. |
| Printer Control: |
Printer initialization to hard reset, disable display functions mode,
enable auto perf-skip. |
| Considerations: |
TTPCL19 contains the same status checks as termtype 19. Because there
are no control sequences to tell the printer what column to start in,
what line spacing to use, what slew should be used, what pitch or
character set the printer should have, the printer can be set directly
thus giving users more flexibility and control. |
Terminal Type 20
This terminal type is supported with device type 32 on MPE V/E and above
operating systems using ADCC or ATP contro11ers. It is used for HP printers
such as the 256X, 263X and 293X series printers where 8 data bits are required.
It is not supported as a remote printer termtype.
| Flow Control: |
XON/XOFF with timer disabled. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in output data, linefeed accepted in
input data, no system response to a backspace, 8 data bits no parity. |
| Printer Control: |
Printer Initialization to disable display functions mode, enable HP
terminal mode, turn off underlining, set ROM1 to secondary character
set, set ROM2 to primary character set, set pitch to 10.0, set line
spacing to 6 lines per inch, clear horizontal tabs, set right margin,
set left margin, hard reset, slew 1 line at line feed, turn on auto
perf-skip, enable char set selection control. |
| Considerations: |
Termtype 20 is used primarily for NLS/3000 where 8 databits are
required. Other than this it is the same as termtype 19 with status
requests sent after each line feed and XOFF. |
Terminal Type 21
This terminal type is supported with device type 32 on MPE V/E and above
operating systems using ADCC or ATP controllers. It is used for HP printers
such as the 256X, 263X and 293X series spooled printers. Its primary use is
to allow the use of embedded printer control escape sequences in the data
which may cause errors with termtype 19 because of status checks after each XOFF.
| Flow Control: |
XON/XOFF with 60 second timer upon receipt of each XOFF. If XON is not
received in 60 seconds a message is displayed at the console and the
CPU continues to wait for a XON |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in input data, linefeed accepted in
input data, no system response to a backspace, 7 data bits odd parity |
| Printer Control: |
Printer initialization to hard reset, disable display functions mode,
enable HP terminal mode, turn off underlining, set ROM1 to secondary
character set, set ROM2 to Primary character set, set print pitch to
10.0, set line spacing at 6 lines per inch, clear horizontal tabs,
set right margin, set left margin, slew 1 line at line feed, turn on
auto perf-skip, disable character set selection control. |
| Considerations: |
This terminal type enables you to insert printer control escape
sequences into data. If this is done using terminal type 19 a printer
error may occur if a status request, as a result of an XOFF, is sent
in the middle of the embedded escape sequence. Terminal type 21 is
also useful in remote applications where a status request may not be
answered in less than 10 seconds which causes a spoolee I/0 error.
This is typically seen when the printer is remote and passes through a
statistical multiplexor. Termtype 21 does not send status requests
after XOFF's. |
Terminal Type 22
This terminal type is supported with device type 32 on MPE V/E and above
operating systems using ADCC or ATP controllers. It is used for HP direct
connect printers such as the 256X, 263X and 293X series spooled printers where
8 data bits are required. It also allows embedded printer control escape
sequences as it does not do status checks after each XOFF. It is not supported
remotely.
| Flow Control: |
XON/XOFF with 60 second timer enabled upon receipt of each XOFF. If an
XON is not received in 60 seconds a message is displayed on the console
and the CPU continues to wait for the XON. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, formfeed allowed in input data, no system response
to a backspace, 8 data bits no parity. |
| Printer Control: |
Printer initialization to disable display functions mode, enable HP
terminal mode, turn off underlining, set ROM1 to secondary character
set, set ROM2 to primary character set, set pitch to 10.0, set line
spacing to 6 lines per inch, clear horizontal tabs, set right margin,
set left margin, slew 1 line at line feed, turn on auto perf-skip,
enable char set selection control. |
| Considerations: |
This terminal type is used for NLS/3000 or extended character sets
where embedded printer control wi11 be used. It is also highly
recommended for 26318 or 293x printers over a statistical multiplexor.
The 256x printers currently are using a special term type file for use
over a mux. The termtype file and patch are available through the
Response Center. |
Terminal Type TTPCL22
This terminal type is supported with device type 32 on MPE V/E and above
operating systems which allow user defined terminal types created with the
workstation configurator. It is shipped on MPE V T-MIT and above installation
tapes. It is used for HP direct connect printers that need termtype 20 or 22
but without any undesirable printer initialization.
| Flow Control: |
XON/XOFF with 60 second timer enabled upon receipt of each XOFF.
If an XON is not received in 60 seconds a message is displayed on
the console and the CPU continues to wait for the XON. |
| Block Mode: |
not supported. |
| Read Trigger: |
DC1 character (XON character) |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, form feed allowed in output data, linefeed accepted
as input data, no system response to a backspace, 8 data bits no parity. |
| Printer Control: |
Printer initialization to hard reset, disable display functions mode,
enable auto perf-skip. |
| Considerations: |
TTPCL22 contains the same characteristics as termtype 22 except for
printer initialization. The printer control on TTPCL22 allows users
to set characterstics directly thus allowing more flexibility. |
Terminal Type 31
This terminal type is supported with device type 16 on all versions of MPE for
ADCC and ATP controllers. This is the default terminal type that is used if
the I/O configuration contains an invalid terminal type name or file. It is
the same as termtype 18 except for system response to a backspace which is a
slash character.
| Flow Control: |
XON/XOFF with timer disabled |
| Block Mode: |
not supported. |
| Read Trigger: |
NUL |
| Special Characters: |
Standard control characters for HP terminals are used. These include
control sequences for console attention, backspace, cancel,
end-of-record and subsystem break. |
| Stripped Characters: |
XON/XOFF characters if handshake disabled, subsystem break if disabled,
NUL, DEL. |
| Terminal Control: |
initial echo on, linefeed accepted during input data, formfeed allowed
in output data, system response to a backspace is a slash character,
7 data bits recognized |
| Printer Control: |
none |
| Considerations: |
If users ever complain of a backslash appearing every time they hit
the backspace key remember that you probably have an invalid terminal
type name or file. |
User Defined Terminal Types
User defined terminal types are supported on MPE V/E and above operating systems
on ADCC and ATP terminal controllers. They are created by a local
area office or buy purchasing the workstation configurator,
(ttutil.pub.sys). This product is used to create any desired terminal
type characteristic. This can be flow control, block mode support, read trigger,
special characters etc... . The most useful advantage however is probably
vertical forms control. Different VFC files can be set up to
initialize printers in different ways.
With the workstation configurator different VFC files can be used
with any given output file using the ENV parameter of the file equation.
This enables users to send any valid escape sequence to the device at spoolfile
initialization. These escape sequences can posistion the cursor, define the
character set, set up line spacing, pitch, slew etc... It also allows the same
port to be used in a number of different ways without reconfiguring.
With different devices coming out, the workstation configurator will allow
users to easily modify termtype characteristics suited to a particular device.
In the past new devices were introduced with options that were not available
because of the terminal type needed to make the device work. The workstation
configurator has been helpful in instantly creating a terminal type that wi11
allow all device characteristics to be used.
| Considerations: |
Workstation Configurator termtype files will show up with 2 question
marks in the assigned termtype field of a sysdump listing. Make sure
a record of the current termtype exists. Problems may occur with
Workstation Configurator files used with terminals running applications
such as Deskmanager or Slate. These products do a fcontrol to find out
the teriminal type and are returned a 0 because a Workstation
Configurator terminal type file is not expected. Because a 0 is
returned, Slate and Desk think they are being run on a dumb terminal
and may not work if the application is block mode. |
Glossary
| Backspace Response: |
When a backspace is entered the previous character is deleted from the
input stream. Different devices expect slightly different codes to
perform this action and cause the desired effect. Most commonly, the
system response to a backspace is nothing. With the workstation
configurator you may also erase the character you backspace to.
Some devices require the end of medium character to move the display
cursor back. Hard copy terminals generally require a line feed to move
the print head one space down so data is not overprinted. For devices
which can not physically move the print head backward an option is
available in which the driver responds to each backspace by sending a
slash character followed by the character deleted which will then give
the user some idea of how many characters have been deleted. |
| Block Mode: |
Block Mode is a method of transferring data from the terminal to the
computer. Instead of sending each character as it is typed, the
terminal buffers a line or more of data and sends the entire block when
the user has pressed ENTER. With the Workstation Configurator you have
the ability to specify the type of block mode supported along with
defining the alert and block trigger characters. |
| Delay Protocol: |
The delay protocol is a method of control intended for printers where
the print head has to physically return when a line feed or form feed
is encountered. The extra time required for this physical movement of
the print bead may result in data overrun or overprinting unless the
delay protocol is added. With the workstation configurator the delay
flow control and delay time variable are optional. |
| Echo: |
When the terminal is in remote mode, in character mode, and local mode
is disabled, characters typed on the keyboard are not placed in the
display by the terminal. The computer must echo (or send back to the
terminal) each character as it is received. When it is desired that
the characters typed not be displayed, such as when entering a password,
echo may be disabled. |
| Enquiry/Acknowledge: |
The ENQ/ACK protocol is a flow control method that is controlled by the
driver. When writing data to the terminal, the driver breaks the data
into blocks. After each block has been written, the driver sends an
enquiry character to the device and waits for an acknowledge character
to come back to the computer. When the device sees the enquiry
character it responds with the acknowledge character if it can accept
the next full block of data. If not, the device waits until it can
accept the next block with an acknowledge. With the Workstation
Configurator the device can be configured so the CPU will send another
block or another enquiry if no acknowledge is received within the 10
second time out. |
| Flow Control: |
Flow Control is the method by which the flow of data between the
computer and the terminal device may be controlled so as to avoid
sending data faster than the receiver can handle it. ENQ/ACK, XON/XOFF,
delay, read trigger and block mode reads are various methods of
handling flow control on a HP 3000 asynchronous port. |
| Form Feed in Output: |
Some devices do not recognize and act upon the formfeed character in
a useful manner. One of the terminal type characteristics available
specifies that each form feed character in the outgoing data stream
may be replaced with a different character. Usually this is the line
feed character. |
| Line Feed in Input: |
Some devices do not provide an automatic wraparound when typing
characters beyond the end of a display line. Without the wraparound,
typing at the end of the line places each character upon all previously
typed characters in the last posistion of the display line. To resolve
this problem the linefeed character may be selected as a special
character. Receipt of the linefeed character causes the HP 3000 to
echo the line feed, write a carriage return character to the terminal
and remove the line feed character from the input data. |
| Parity: |
Parity is a means of verifying that data is transmitted between the
terminal and computer without error. These bits may an be used for the
character code (with 256 possible character codes available), or seven
bits used for the character code (allowing 128 characters) and the
eighth bit used as a parity bit.
If seven data bits are used there are 4 possible parity settings:
force to 0 where the parity bit is always 0, force to 1, odd or even
parity where the parity bit is set to either 0 or 1 so that the total
number of 1 bits in the eight bit character is either even or odd
depending on the parity type enabled. |
| Printer Control: |
When a printer is shared among users each user may want to use the
printer in a different way and consequently alter the settings on
the printer by direct changes or escape sequences. The user may change
characteristics such as margins, tabs, print density and pitch thus
affecting the next user who does not neccesarily want those choices
of characteristics.
To prevent 1 user from affecting the next user,
the printer must be initialized to a default known state before
printing the next job. When the device open occurs on a type 32 device,
the port controller software writes an initialization character string
to the device. This string is determined by the currently active
terminal type. |
| Read Trigger: |
The read trigger is used to tell the terminal device when it should
start to send characters to the HP 3000. In other words, it is a
method of preventing a device from sending input characters before the
HP 3000 is ready to accept them. Once the HP 3000 sends the read
trigger character, input can proceed. |
| Special Characters: |
There are several characters which have special significance to the
terminal driver. These characters cause the driver to take special
actions. With the Workstation Configurator, you are able to define the
characters that cause each of the following special actions: console
attention, backspace, cancel, end-of-record and subystem break. |
| Stripped Characters: |
With the Workstation Configurator, you are able to define a set of
characters which have no special function other than to be removed
from the input data. When these characters are typed, they are ignored
and do not show up in the data read. For example, if the XON/XOFF flow
control is not enabled, then one of the terminal type options allow
you to specify that XON and XOFF be stripped from input. if a
subsystem break character is entered when subsystem breaks are not
enabled, the character may be removed from the input stream. If the
console attention character is entered from a terminal which is not
the console, it may be ignored or treated as a data character. |
| Terminal Control: |
There are several characteristics which allow you to have some control
over the terminal. With the Workstation Configurator you are able to
control each of the following terminal type characteristics: Echo,
Line feed during input, Formfeed during output, backspace response and
parity. |
| Vertical formats: |
Many printers allow the use of Vertical Format Control
(VFC). VFC allows a programmer to instruct a printer to
skip to predetermined lines on page with certain carriage control
directives instead of counting and outputting a number of blank lines.
With the Workstation Configurator, each VFC character
sequence (up to a maximum of 16 characters each) may be defined. When
one of the VFC carriage controls is used (%300 to %317), the
driver generates the character sequence necessary to move the printer
carriage to the proper channel. For further information on Vertical
Format Control, refer to the "MPE V System Operation and Resource
Management Manual". |
| XON/XOFF Protocol: |
In contrast to the other methods, this is controlled by the terminal
device. The driver sends data to the device in a continuous stream.
If the device can no longer accept data (because of being put offline,
filling its buffer, running out of paper, etc.), it sends the XOFF
character to the driver. The driver then stops sending data to the
device. When the device is able to accept data again, it sends the XON
character to the driver and the driver resumes data transmission to
the device.
With the Workstation Configurator, you can specify if a timer should
be started when the XOFF character is received. If a timer is started
and the timer expires before the XON character is received, a message
is printed on the console stating that the device is offline. The
timer duration can be specified from one to 255 seconds. |
|