HP 3000 Manuals

Using Extin' in HP Pascal [ COMMUNICATOR 3000 XL, XL Release 1.1 (Core Software Release A.10.00) ] MPE/iX Communicators


COMMUNICATOR 3000 XL, XL Release 1.1 (Core Software Release A.10.00)

Using Extin' in HP Pascal 

by Sue Kimura, Information Systems Division 

Users must modify calls to the compiler library intrinsic EXTIN'.
Specifically, use of the Pascal predefine WADDRESS must be removed from
the result parameter to EXTIN'.

The result parameter in the intrinsic declaration for EXTIN' has been
modified in Release 1.1.  The result parameter has been changed from an
integer by value parameter to an ANYVAR parameter.

Consequently, a program with a call to EXTIN' which successfully compiled
on Release 1.0 will encounter error 208, "Actual parameter not compatible
with formal parameter" , on Release 1.1.  Removal of WADDRESS will fix
this compilation error.


MPE/iX Communicators