HP 3000 Manuals

DCE for the HP 3000 MPE/iX 5.0 Documentation


DCE for the HP 3000

Table of Contents

 DCE for the HP 3000
   DCE for the HP 3000 : COPYRIGHT NOTICE

   Ch 1.  General Information
      Version Identification
      DCE/3000 Components and Files
      Domestic and International Versions
      Configuration and Diagnostic tools
      Release Limitations
          Limitations of OSF DCE 1.0.2
          Unsupported Configurations
          Interoperability of the Domestic and International Versions
          Kerberos Authentication Protocol Compatibility
          Security for DCE User Accounts
      DCE/3000 versus DCE/9000: Differences
          File Naming Convention
          Managing DCE Deamons
          Security and Remote Login Utilities
      Release Documents

   Ch 2.  Installing DCE/3000 Software
      Hardware and Software Requirements
      Distribution Media
      Preinstallation Planning
          Determining Cell Boundaries
          Intercell Communications
      Accounting Structure Change
      Checking the System State
      Installation

   Ch 3.  Configuring DCE Cells
      Using the DCE Configuration Tool
      Using the DCE Configuration Options
          Configuring an Initial Cell
          Configuring a DTS Server
          Configuring a DCE Client (Client-Only System)
          Removing or Reconfiguring a Client
          Removing or Reconfiguring a Server

   Ch 4.  Programming Notes
      Threads Architecture
          Threads on MPE/iX
          Process Management and Threads
          Development, Debugging, and Application Execution of Threads
             Breakpoints
             Commands
             Environmental Variables
             Limitations
      Building DCE Programs
          Header Files
          Compiler Flags
          Unresolved Externals
          MPE/iX Makefile Example
          HP-UX Makefile Example

   Ch 5.  Programming with Kernel Threads
      Threads Synchronization and Communication
          Mutexes (Mutual Exclusion Objects)
          Condition Variables
          Join Facility
      Threads Scheduling
      Writing Threaded Applications
      Writing Thread-Safe Code
      Reentrant Interfaces
      stdio Interfaces
      Debugging Threaded Applications
      Process Management Commands
      Process Management Intrinsics
      Changes to AIF Routines
      Input Reference Parameter Protection for Intrinsics
      File Access From Threads
      GlanceXL
      XL.PUB.SYS
      PTHREAD Intrinsics



MPE/iX 5.0 Documentation