HP 3000 Manuals

Direct Connect Link Configuration [ NS3000/iX NMMGR Screens Reference Manual ] MPE/iX 5.0 Documentation


NS3000/iX NMMGR Screens Reference Manual

Direct Connect Link Configuration 

The Direct Connect Link Configuration screen (#105) supplies the
information required to interface a gateway-half NI to a non-dial link
(that is, a leased line or a hardwired connection).  This screen, shown
in figure 10-9, is displayed when you select an NI link name and the link
type DC at the Gateway Half Network Interface Link screen (figure 10-8)
and press the [Add] or [Modify] function key.  It is also displayed when
you type the path name:

@NETXPORT.NI.NIname.LINK.linkname 

in the command window of any screen and press the [Enter] key, where
NIname is the configured gateway half NI, and linkname is the configured
gateway half NI link.

[]
Figure 10-9. Direct Connect Link Configuration Press the [Save Data] function key to transfer the data displayed on the screen to the configuration file you are creating or updating. Verify that the data record has been created by checking that the Data flag is set to Y. Fields Start device on network A Y (Yes) value means that the device is to be initialization (Y/N) started when a NETCONTROL START command is issued for the network interface being configured.An N (No) means that a NETCONTROL ADDLINK command must be used to start the device. Default value: Y Range: Y or N Enable idle device timer This field specifies whether the device is to (Y/N) be disconnected automatically if no packets have been received or transmitted over the link during a specified time period. This field is relevant only if a timeout value has been entered in the network interface screen listed below. Related screens: * NETXPORT.NI.NIname The idle device timeout value is configured on this screen. Default value: N Range: Y or N


MPE/iX 5.0 Documentation