HP 3000 Manuals

Ch 4. Revised DBChange Plus Messages [ DBChange Plus Technical Addendum for MPE/iX Release 4.0 ] MPE/iX 5.0 Documentation


DBChange Plus Technical Addendum for MPE/iX Release 4.0

Chapter 4  Revised DBChange Plus Messages 

70           MESSAGE    New item type cannot be converted from current
                      item type/len (DBC 70).

           MEANING    When changing data item attributes, the new data
                      item type must be able to convert from the existing
                      data item type, or the length must be equivalent to
                      2 or 4 halfwords when using !E.

           ACTION     Refer to Table 2-1  or Table 3-1  for
                      information on available type conversions between
                      different item types.

108          MESSAGE    Sub-item length for item type E or R must be 2 or
                      4 (DBC 108).

           MEANING    The specified length is invalid for item type E or
                      R.

           ACTION     Specify a subitem length of either 2 or 4.

204          MESSAGE    Type must be [!]E, I, J, K, P, R, U, X, or Z (DBC
                      204).

           MEANING    A data item type was entered that was not [!]E, I,
                      J, K, P, R, U, X, or Z.

           ACTION     Enter a valid data item type.  Refer to the
                      TurboIMAGE/XL DBMS Reference Manual for a list of
                      types accepted by TurboIMAGE/XL.



MPE/iX 5.0 Documentation