Ch 4. Revised DBChange Plus Messages [ DBChange Plus Technical Addendum for MPE/iX Release 4.0 ] MPE/iX 5.0 Documentation
DBChange Plus Technical Addendum for MPE/iX Release 4.0
Chapter 4 Revised DBChange Plus Messages
70 MESSAGE New item type cannot be converted from current
item type/len (DBC 70).
MEANING When changing data item attributes, the new data
item type must be able to convert from the existing
data item type, or the length must be equivalent to
2 or 4 halfwords when using !E.
ACTION Refer to Table 2-1 or Table 3-1 for
information on available type conversions between
different item types.
108 MESSAGE Sub-item length for item type E or R must be 2 or
4 (DBC 108).
MEANING The specified length is invalid for item type E or
R.
ACTION Specify a subitem length of either 2 or 4.
204 MESSAGE Type must be [!]E, I, J, K, P, R, U, X, or Z (DBC
204).
MEANING A data item type was entered that was not [!]E, I,
J, K, P, R, U, X, or Z.
ACTION Enter a valid data item type. Refer to the
TurboIMAGE/XL DBMS Reference Manual for a list of
types accepted by TurboIMAGE/XL.
MPE/iX 5.0 Documentation