SWITCHOVER 

Initiates the switchover of volume sets from one system to another.

Syntax 

SWITCHOVER [FROM=]homesystem [[TO=]altsystem]

Parameters 

homesystem            Indicates the name of the failed system as
                      specified in the SYSGEN ASYSTEM command.  When the
                      operator enters the command, volume sets specified
                      in the configuration as belonging to homesystem are
                      switched over and mounted to the altsystem.

altsystem             Indicates the name of the alternate system as
                      specified in the SYSGEN ASYSTEM command.  When the
                      operator enters the command from altsystem, volume
                      sets specified in the configuration that belong to
                      homesystem are switched over and mounted to the
                      altsystem.

Operation Notes 

The operator must enter the command from the alternate system console.
The operator should enter the command after deciding that switching over
is preferable to rebooting the home system.

The operator can also enter this command when the home system is
operative in order to perform maintenance, to reconfigure, or to load
balance the home system.


NOTE This command is entered on the system where the volume sets are going to.
If the home system is inoperative, the system status message stops between the home system and the alternate system. If the home system is operative, the system status message continues during the switchover. The operator can enter the command within a session, a job, a program, or in break mode. The following sequence must occur before an operator can enter the SWITCHOVER command: 1. The SPU Switchover/XL environment must be properly configured using the SYSGEN utility SPU commands. 2. The configuration must be activated using the SPUCONTROL SETUP command. 3. The SPU Switchover/XL environment must be activated using the SPUCONTROL START command. 4. If the home system is operative, the switchable nonsystem volume sets must be closed. For this command to function properly, the SPU configuration file must include a pair with homesystem as the home system and altsystem as the alternate system. The operator must have OP or SM capability to enter this command. Example The following command is entered from the alternate system's console (Beta) when a system failure or load balancing occurs: : SWITCHOVER FROM=ALPHA TO=BETA Return The alternate system (Beta) responds by displaying the following message: /00:00/nn/SPU SWITCHOVER FROM ALPHA TO BETA STARTING. You must reply to the following message that appears when switchover has successfully finished: /00:00/nn/ACKNOWLEDGE SPU SWITCHOVER FROM ALPHA TO BETA COMPLETE (Y/N)? =REPLY nn,Y This message is displayed every 30 seconds until the operator acknowledges completion of the switchover. The reply has no effect except to stop the repeating message.