HP 3000 Manuals

Emergency Switchovers [ SPU Switchover/XL User's Guide ] MPE/iX 5.0 Documentation


SPU Switchover/XL User's Guide

Emergency Switchovers 

The following procedure assumes that Alpha has experienced a hardware
failure and has stopped sending system status messages to Beta.  This
procedure enables a system operator to switch control of switchable
volume sets from the home system (Alpha) to the alternate system (Beta).

   1.  Verify and respond to the following message that appears when the
       home system (Alpha) does not respond to the system status messages
       from the alternate system (Beta):

            /00:00/nn/ACKNOWLEDGE SYSTEM ALPHA NOT RESPONDING.
            PLEASE CHECK ALPHA (Y/N)?

       This message is displayed every 30 seconds until the operator
       acknowledges the problem.

   2.  Attempt to dump and reboot the home system to rule out a software
       failure.  If a software failure has not occurred, proceed to the
       next step.

   3.  Verify that the problem involves a hardware failure, then, if
       necessary, log off existing jobs and sessions on the alternate
       system (Beta) so that it can accept the additional processing load
       from the home system (Alpha).

   4.  Enter the following command from the alternate system's console
       (Beta):

            : SWITCHOVER FROM=ALPHA TO=BETA Return 

       The alternate system (Beta) responds by displaying the following
       message:

            /00:00/nn/SPU SWITCHOVER FROM ALPHA TO BETA STARTING.

       After this message appears, the alternate system (Beta) does the
       following:

          a.  Unlocks the currently locked switchable volume sets on the
              home system (Alpha).

          b.  Locks and opens the volume sets on the alternate system
              (Beta).

          c.  Displays a message for each volume set indicating that
              switch over of that set is complete.

          d.  Reply to the following message that appears when switchover
              has successfully finished:

                   /00:00/nn/ACKNOWLEDGE SPU SWITCHOVER FROM ALPHA
                   TO BETA COMPLETE (Y/N)?

                   =REPLY nn,Y 

              This message is displayed every 30 seconds until the
              operator acknowledges completion of the switchover.

          e.  Enter the SPUCONTROL STATUS command to verify the status of
              the SPU Switchover/XL environment.

                   : SPUCONTROL STATUS Return 
___________________________________________________
|                                                 |
|     System   Volume Sets             Home System|
|     ------   -----------             -----------|
|     Beta     b_test_software_set     Beta       |
|              b_benchmark_set         Beta       |
|              a_production_data_set   Alpha      |
|              a_user_vol_set          Alpha      |
|              a_mirror_disk_set       Alpha      |
___________________________________________________

          Figure 3-1.  Example SPUCONTROL STATUS Command Display 

          f.  Restart applications and terminal sessions on Beta that
              previously ran on Alpha.  Refer to Chapter 5  for
              information on performing terminal switchovers.

          g.  Inform users that they can log on to Beta.



MPE/iX 5.0 Documentation