0500 MESSAGE **warning** missing optional parameter
-------------------------------------------------------------
0520 MESSAGE **warning** Information display only mode !!!
CAUSE The account has insufficient capability to make
configuration changes. You can view configuration
data only.
ACTION Add SM capability or access an account, if allowed,
with SM capability.
-------------------------------------------------------------
0530 MESSAGE **warning** offline list device not currently
open
CAUSE This error is caused when the OCLOSE command is
entered and nothing has yet been sent.
ACTION You must have used DEST=OFFLINE at least once since
beginning SYSGEN or the last OCLOSE.
-------------------------------------------------------------
0535 MESSAGE **warning** Can't find CM procedure doccnmdata!
-------------------------------------------------------------
1000 MESSAGE **error** Can't open file !
CAUSE SYSGEN cannot open the designated file. Usually,
the file does not exist.
ACTION check that you entered the proper file name.
-------------------------------------------------------------
1001 MESSAGE **error** FFILEINFO error on file !
CAUSE The FFILEINFO intrinsic returned an error for file
!
ACTION Refer to the file system error message, also
returned.
-------------------------------------------------------------
1002 MESSAGE **error** can't open output device
-------------------------------------------------------------
1003 MESSAGE **error** The string ! is too long! (int. catalog
error)
-------------------------------------------------------------
1004 MESSAGE **error** You must have SM capability to make a
tape!
CAUSE The TAPE command has been entered from an account
that does not have SM capability. Generally, you
are in the wrong account and you try to generate a
tape.
ACTION Add SM capability or, if allowed, access an account
with SM capability.
-------------------------------------------------------------
1005 MESSAGE subsys=! error=!
CAUSE Continuation of previous message.
ACTION Continuation of previous message.
-------------------------------------------------------------
1006 MESSAGE **error** Can't write to offline list device!
CAUSE The offline device is probably connected and
active, but the output spooling function is not.
ACTION Use the STARTSPOOL command and appropriate device
number from the master console to activate the
output spooling function.
-------------------------------------------------------------
1007 MESSAGE **error** Can't closs offline list device!
CAUSE For whatever reason, SYSGEN cannot close the list
device.
ACTION
-------------------------------------------------------------
1008 MESSAGE **error** You must have SM capability to do a
KEEP!
-------------------------------------------------------------
1009 MESSAGE **error** user has insufficient capability.
SYSGEN TERMINATES.
CAUSE The account has insufficient capability to allow
you to change or view SYSGEN data. You are
probably trying to access SYSGEN from the wrong
account.
ACTION Use the SHOWME command to see the current account.
Log on to an account with sufficient capability to
request the operator to add the capability to your
account.
-------------------------------------------------------------
1010 MESSAGE **error** Catalog is missing a path type message.
-------------------------------------------------------------
1011 MESSAGE **error** You must have SM capability to make
changes
-------------------------------------------------------------
1012 MESSAGE **error** Can't close a permanent configuration
file
CAUSE For whatever reason, SYSGEN cannot close the
configuration data file from that data was written
from one or more temporary files. Program dies.
ACTION Refer to the file system error for action.
-------------------------------------------------------------
1013 MESSAGE **error** Can't read a permanent configuration
file
-------------------------------------------------------------
1014 MESSAGE **error** Can't write a permanent configuration
file
-------------------------------------------------------------
1015 MESSAGE **error** Can't FPOINT a permanent configuration
file
-------------------------------------------------------------
1016 MESSAGE **error** Redo only valid interactively
-------------------------------------------------------------
1018 MESSAGE **error** language localized devtype name too
long.
-------------------------------------------------------------
1020 MESSAGE **error** switch to alterrin failed. Switch
error=!
-------------------------------------------------------------
1021 MESSAGE **error** switch to compactrin failed. Switch
error=!
-------------------------------------------------------------
1022 MESSAGE **error** switch to deleterin failed. Switch
error=!
-------------------------------------------------------------
1023 MESSAGE **error** switch to initrin failed. Switch
error=!
-------------------------------------------------------------
1024 MESSAGE **error** switch to listrin failed. Switch
error=!
-------------------------------------------------------------
1025 MESSAGE **error** switch to dtermctyp failed. Switch
error=!
-------------------------------------------------------------
1026 MESSAGE **error** switch to segmenter failed. Switch
error=!
-------------------------------------------------------------
1027 MESSAGE **error** switch to dccmdata failed. Switch
error=!
-------------------------------------------------------------
1030 MESSAGE **error** error* Can't find CM procedure
dtermctyp!
-------------------------------------------------------------
1035 MESSAGE **error** set ! (message !) not found in message
catalog
CAUSE A message set is missing from SYSGEN's message
catalog.
-------------------------------------------------------------
1036 MESSAGE **error** message number ! of set ! not found in
message catalog
CAUSE A message is missing from SYSGEN's message catalog.
-------------------------------------------------------------
MPE/iX 5.5 Documentation