HP 3000 Manuals

CLOSELOG [ MPE/iX Intrinsics Reference Manual ] MPE/iX 5.0 Documentation


MPE/iX Intrinsics Reference Manual

CLOSELOG 

NM and CM callable.

Closes access to the user logging facility.  User logging (LG) or system
supervisor (OP) capabilities are required.

Syntax 
______________________________________
|                                    |
|               I32   I16    I16     |
|     CLOSELOG(index,mode,logstatus);|
______________________________________

            

Parameters 

index                 32-bit signed integer by reference (required) 

                      Passes access capabilities to the user logging
                      system.  This is the value returned in the index 
                      parameter of the OPENLOG intrinsic.

mode                  16-bit signed integer by reference (required) 

                      Passes a value, indicating whether the user logging
                      facility should suspend the process if it cannot
                      complete the request for service immediately:

                         Value    Meaning 

                           0      Wait

                           1      Nowait

logstatus             16-bit signed integer by reference (required) 

                      Returns one of the following values, indicating the
                      success/failure of the intrinsic call:

                         Value    Meaning 

                           0      Successful

                           1      Nowait mode requested; user logging process busy

                           4      Incorrect index parameter passed

                           5      Incorrect mode parameter passed

                           7      Illegal capability; user logging (LG) or system
                                  supervisor (OP) capabilities required

                           9      Error occurred while writing

                          12      System out of disk space; user logging cannot proceed

                          14      Invalid access to user logging file

                          15      End-of-file encountered

Operation Notes 

The number of users and log entries are independent of the number of
times the OPENLOG/CLOSELOG intrinsics are called within an application.
The user logging facility establishes a logging buffer (LOGBUFF) entry
and increments the user count only at the first OPENLOG call.  Another
counter keeps track of the number of times OPENLOG and CLOSELOG are
called.  The counter is incremented for every OPENLOG and decremented for
every CLOSELOG. This ensures that the entry in LOGBUFF is released only
for the last CLOSELOG call (call counter = 0).

Related Information 

Intrinsics            OPENLOG

Commands              None

Manuals               User Logging Programmer's Guide (32650-90027)