PRINTOPREPLY 

NM and CM callable.

Prints a character string on the system console and solicits a reply.

Syntax 
________________________________________________
|                                              |
|      I16                   CA    I16V  I16V  |
|     length:=PRINTOPREPLY(message,length,zero,|
|                          CA     I16V         |
|                         reply,maxlength);    |
________________________________________________

            

Functional Return 

length                16-bit signed integer (assigned functional return) 

                      Passes the length of the reply from the system
                      operator.  This length represents a half word count
                      if maxlength is positive or a byte count if
                      maxlength is negative.

                      If maxlength is zero, then this intrinsic does not
                      solicit a reply.

                      If an error occurs, the value returned is zero.

                      The length parameter can be zero, in which case
                      only the standard message prefix is written on the
                      system console .  If both length and maxlength are
                      zero, then CCL (1) is returned.

Parameters 

message               character array (required) 

                      Passes the characters that are output to the system
                      console.  The character string is limited to 50
                      characters, additional characters are ignored.

length                16-bit signed integer by value (required) 

                      The length of the output string to be transmitted.
                      If length is positive, the length is in half words;
                      if negative, the length is in bytes.  Do not
                      specify a length of >50 bytes.

zero                  16-bit signed integer by value (required) 

                      Do not specify this parameter, but maintain
                      parameter position with a value of 0.

reply                 character array (required) 

                      Returns the input characters read from the system
                      console.

maxlength             16-bit signed integer by value (required) 

                      The maximum length of the message to be read into
                      the reply parameter.  If the expected length is
                      positive, it specifies a half word count; if
                      negative, it specifies a byte count.  Do not
                      specify a length of >31 bytes.

Condition Codes 

CCE (2)               Request granted.

CCG (0)               Not returned.

CCL (1)               Request denied.  A physical I/O error occurred.
                      Further error analysis through the FCHECK intrinsic
                      is not possible.

Related Information 

Intrinsics            None

Commands              None

Manuals               Accessing Files Programmer's Guide (32650-90017)



MPE/iX 5.0 Documentation