HP 3000 Manuals

NLFMTCLOCK [ MPE/iX Intrinsics Reference Manual ] MPE/iX 5.0 Documentation


MPE/iX Intrinsics Reference Manual

NLFMTCLOCK 

NM and CM callable.

Formats the time of day, in the specified language, obtained with the
CLOCK intrinsic.

Syntax 
_____________________________________________
|                                           |
|                I32V   CA    I16V   U16A   |
|     NLFMTCLOCK(time,buffer,langnum,error);|
_____________________________________________

            

Parameters 

time                  32-bit signed integer by value (required) 

                      Contains the time format returned by the CLOCK
                      intrinsic:

                         Bits     Value/Meaning 

                         24:8     Tenths of seconds

                         16:8     Seconds

                          8:8     Minute of hour

                          0:8     Hour of day

buffer                character array (required) 

                      Returns the formatted time of day in an 8-character
                      array.  Using a buffer of a different size may
                      produce unexpected results.

langnum               16-bit signed integer by value (required) 

                      Contains the language ID number, specifying which
                      format to use.  A langnum of 0 returns the time
                      formatted as if you used FMTCLOCK.

error                 16-bit unsigned integer array (required) 

                      Returns two elements:  the first element is the
                      error number; the second element is reserved and
                      always returns 0.  The possible error number values
                      are:

                         Value    Meaning 

                           0      Successful

                           1      *NLS not installed

                           2      *Specified language not configured

                           3      Invalid time format

                           4      *NLS internal error

                           5      *NLS internal error

                           6      *NLS internal error

                      * Do not apply to calls with a langnum equal to 0
                      (NATIVE3000/XL).

Related Information 

Intrinsics            NLCONVCLOCK, NLCONVCUSTDATE, NLFMTCALENDAR,
                      NLFMTCUSTDATE, NLFMTDATE, NLFMTLONGCAL

Commands              None

Manuals               Native Language Programmer's Guide (32650-90022)