Holding and Saving Configuration Changes [ System Startup, Configuration, and Shutdown Reference Manual ] MPE/iX 5.0 Documentation
System Startup, Configuration, and Shutdown Reference Manual
Holding and Saving Configuration Changes
Using the SYSFILE configurator commands described in the previous
sections changes the configuration specified in the SYSGEN command line
or global BASEGROUP command. These changes are temporary and are lost if
not properly saved.
Saving configuration changes is a two-step procedure. After you alter a
configuration, you must first, hold the changes before exiting the
configurator. Second, use the global module KEEP command to save the
changes.
To hold changes, enter the HOLD command (abbreviated HO) at the SYSFILE
configurator prompt:
sysfile>HOLD
You can work in a SYSGEN configurator, hold the changes, and continue
working in another SYSGEN configurator before saving the changes.
To save the changes, hold all desired changes, exit to SYSGEN's global
module, and issue the KEEP command (abbreviated KE or K):
sysgen>KEEP newgroupname
MPE/iX 5.0 Documentation