Holding and Saving Configuration Changes 

Using the MISC configurator commands described in the previous sections
changes the configuration specified in the SYSGEN command line or global
BASEGROUP command.  These changes are temporary and are lost if not
properly saved.

Saving configuration changes is a two-step procedure.  After you alter a
configuration, you must first hold the changes before exiting the
configurator.  Second, use the global module KEEP command to save the
changes.

To hold changes, enter the HOLD command at the MISC configurator prompt:

     misc>HOLD 

You can work in a SYSGEN configurator, hold the changes, and continue
working in other SYSGEN configurators before saving the changes.

To save the changes, first hold all desired changes, exit to SYSGEN's
global module, and issue the KEEP command:

     sysgen>KEEP newgroupname 

For additional information on using the KEEP command, refer to Chapter 4
.