Operation [ MPE/iX System Utilities Reference Manual ] MPE/iX 5.0 Documentation
MPE/iX System Utilities Reference Manual
Operation
To invoke SYSMAP enter:
SYSDIAG
DUI> RUN SYSMAP
SYSMAP is part of the Online Diagnostics Subsystem. To use this utility,
start the diagnostic subsystem by entering SYSDIAGand at the DUI> prompt,
enter RUN SYSMAP.
Once you are in the SYSMAP subsystem, you can choose one of three basic
map options:
ENTER MAP> CPUMAP
ENTER MAP> MEMMAP
ENTER MAP> IOMAP
If you choose CPUMAP the system displays the following for each CPU:
hardware model and revision number, software model and revision number
and slot number.
If you choose MEMMAP the system responds by listing memory controller's
and arrays, slot numbers, hard physical addresses and memory size.
If you choose IOMAP the system responds by presenting the IOMAP> prompt.
At this prompt you may choose one of three responses:
IOMAP> GENERAL
IOMAP> CLASS
IOMAP> STEPPING
* GENERAL displays a general map of the I/O configuration.
* CLASS maps all devices in the device class you specify.
* STEPPING displays all system hardware configurations or all
configurations from a specific physical address on down.
Additional Discussion
Precision Architecture: HP 3000/9xx & HP 9000/8xx Online Diagnostics
Subsystem Utilities Manual (09740-64007).
MPE/iX 5.0 Documentation