Class Error (contd.) [ MPE/iX Error Messages Manual Volume II ] MPE/iX 5.0 Documentation
MPE/iX Error Messages Manual Volume II
Class Error (contd.)
Class Error 5: Bus Protocol Failure
Bus protocol messages takes the form:
5sxx
where:
s = slot number
xx = detailed error number.
---------------------------------------------------------------
00 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurs at the start of this test.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
Class Error 7: Memory Failure
Class Error 7
memory error messages takes the form:
7sxx
where:
s = slot number
xx = detailed error number.
NOTE The memory test takes about 1.5 seconds per MB of memory.
---------------------------------------------------------------
00 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurs at the start of the test of
this board.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
01 MESSAGE No message. System halts. (E)
CAUSE Either stuck bit occurs in I/O status register or
cannot find four contiguous words within the first
256 KB without a single bit error.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
02 MESSAGE No message. System halts. (E)
CAUSE Verification of the memory with its address fails.
Second possible cause of the error is the cache
unit. Third possible cause of the error is the
TLB.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
03 MESSAGE No message. System halts. (E)
CAUSE Pattern testing memory fails. Second possible
cause of the error is the cache unit. Third
possible cause of the error is the TLB.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
04 MESSAGE No message. System halts. (E)
CAUSE Multiple bit error flag is set by single bit error.
Second possible cause of the error is the cache
unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
05 MESSAGE No message. System halts. (E)
CAUSE Multiple bit error flag is not set by multiple bit
error. Second possible cause of the error is the
cache unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
06 MESSAGE No message. System halts. (E)
CAUSE Memory controller cannot calculate the address of
the faulty memory. Second possible cause of the
error is the cache unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
07 MESSAGE No message. System halts. (E)
CAUSE Single bit error is detected. Second possible
cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0A MESSAGE No message. System halts. (E)
CAUSE Parity checking/generator is not working. Second
possible cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0B MESSAGE No message. System halts. (E)
CAUSE Verification of read/write protocol fails. Second
possible cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0C MESSAGE No message. System halts. (E)
CAUSE Verification of read and Clear protocol fails.
Second possible cause of the error is the cache
unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
10 MESSAGE No message. System halts. (E)
CAUSE Undefined type of memory controller is found.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
11 MESSAGE No message. System halts. (E)
CAUSE Error occurs as "hole" in memory is detected.
ACTION Install 32 MB memory controller. Contact your
Hewlett-Packard Support Representative.
---------------------------------------------------------------
12 MESSAGE No message. System halts. (E)
CAUSE Last memory controller does not have a memory array
installed.
ACTION Contact your Hewlett-Packard Support
Representative. Install memory array.
---------------------------------------------------------------
13 MESSAGE No message. System halts. (E)
CAUSE Last 8 MB (3 MB MC and 5 MB MA) memory controller
does not have a memory array installed.
ACTION Contact your Hewlett-Packard Support
Representative. Install memory array.
---------------------------------------------------------------
2F MESSAGE No message. System halts. (E)
CAUSE No memory board is found during initialization.
Second possible cause of the error is the cache
unit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
Class Error 8: Channel Adapter Test
Channel adapter test messages take the form:
8sxx
where:
s = slot number
xx = detailed error number.
NOTE The channel adapter test takes about 5 seconds to perform.
---------------------------------------------------------------
00 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurs at the start of the test of
this board.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
01 MESSAGE No message. System halts. (E)
CAUSE Cannot enable soft physical address. (Cannot set
the SSET bit.)
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
02 MESSAGE No message. System halts. (E)
CAUSE Cannot disable soft physical address. (Cannot
reset SSET bit to zero.)
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
03 MESSAGE No message. System halts. (E)
CAUSE Cannot verify memory with its address.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
04 MESSAGE No message. System halts. (E)
CAUSE Cannot verify memory with sliding ones.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
05 MESSAGE No message. System halts. (E)
CAUSE Cannot verify memory with sliding zeros.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
06 MESSAGE No message. System halts. (E)
CAUSE Cannot verify memory with all zeros.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
07 MESSAGE No message. System halts. (E)
CAUSE Pattern testing of external interrupt enable mask
register fails.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
08 MESSAGE No message. System halts. (E)
CAUSE Cannot set interrupt register to zero.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
09 MESSAGE No message. System halts. (E)
CAUSE Pattern testing of interrupt register fails.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0A MESSAGE No message. System halts. (E)
CAUSE Pattern testing of chain RAM base register fails.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0B MESSAGE No message. System halts. (E)
CAUSE Failure encountered while pattern testing mask
register.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0E MESSAGE No message. System halts. (E)
CAUSE Pattern testing of reset address register fails.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
0F MESSAGE No message. System halts. (E)
CAUSE Pattern testing of reset data register fails.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
10 MESSAGE No message. System halts. (E)
CAUSE Reset does not clear soft physical address (SPA).
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
11 MESSAGE No message. System halts. (E)
CAUSE Either a channel I/O card is not installed, or none
of the CIO cards pass the self-test and are ready
for command.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
12 MESSAGE No message. System halts. (E)
CAUSE Stop command does not set the ready (RDY) bit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
13 MESSAGE No message. System halts. (E)
CAUSE Chain command does not clear the RDY bit.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
14 MESSAGE No message. System halts. (E)
CAUSE Cannot get an interrupt at the end of DMA.
(Appropriate bit in submask register not set.)
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
15 MESSAGE No message. System halts. (E)
CAUSE DMA does not transfer data.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
16 MESSAGE No message. System halts. (E)
CAUSE RDY bit is not set at the end of DMA.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
17 MESSAGE No message. System halts. (E)
CAUSE CIO card returns wrong status after the subchannel
is disconnected.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
18 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurs with a CIO card. RFC, PST,
PRE, or LVI do not match.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
1A MESSAGE No message. System halts. (E)
CAUSE Hewlett-Packard IB loopback test reports data write
status error.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
1B MESSAGE No message. System halts. (E)
CAUSE Hewlett-Packard IB cannot get ready for command.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
1C MESSAGE No message. System halts. (E)
CAUSE Hewlett-Packard IB loopback test reports undefined
status error.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
1D MESSAGE No message. System halts. (E)
CAUSE Hewlett-Packard IB loopback test reports data
error.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
1E MESSAGE No message. System halts. (E)
CAUSE Channel does not request attention after
disconnecting the subchannel.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
20 MESSAGE No message. System halts. (E)
CAUSE Cannot verify link to previous link status block.
ACTION Contact your Hewlett-Packard Support
Representative.
---------------------------------------------------------------
MPE/iX 5.0 Documentation