Class Errors 

Class Error 1 

Class Error 1

Class error 1 is composed of three types of processor failures:  register
file, execution unit, and instruction unit.

Register File Failure.   

Register file messages take the form:

       11xx

where:

       xx = detailed error number

---------------------------------------------------------------

 00          MESSAGE    No message. System halts. (E)

           CAUSE      Undefined error occurs at the start of the test.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 01          MESSAGE    No message. System halts. (E)

           CAUSE      Test of the general registers 1, 2, and 31 fails.
                      Second possible cause of the error may be the
                      execution unit.  Third possible cause of the error
                      also may be the instruction unit.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 02          MESSAGE    No message. System halts. (E)

           CAUSE      Test of the general registers fails.  Second
                      possible cause of the error may be the execution
                      unit.  Third possible cause of the error also may
                      be the instruction unit.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 03          MESSAGE    No message. System halts. (E)

           CAUSE      Test of the recovery counter or external interrupt
                      enable mask fails.  Second possible cause of the
                      error may be the execution unit.  Third possible
                      cause of the error also may be the instruction
                      unit.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 04          MESSAGE    No message. System halts. (E)

           CAUSE      Test of the temporary control registers fails.
                      Second possible cause of the error may be the
                      execution unit.  Third possible cause of the error
                      also may be the instruction unit.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 07          MESSAGE    No message. System halts. (E)

           CAUSE      Cross-talk occurs between general registers.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 08          MESSAGE    No message. System halts. (E)

           CAUSE      Crosstalk occurs among general registers and
                      temporary registers.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 0A          MESSAGE    No message. System halts. (E)

           CAUSE      X and B bus bypass testing.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 0B          MESSAGE    No message. System halts. (E)

           CAUSE      General register 0 bypassed.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 0C          MESSAGE    No message. System halts. (E)

           CAUSE      General register 0 bypassed on a nullify.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 0D          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the trap with interval timer fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 10          MESSAGE    No message. System halts. (E)

           CAUSE      Interval timer is not incrementing.  Second
                      possible cause of the error may be the execution
                      unit.  Third possible cause of the error also may
                      be the instruction unit.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 11          MESSAGE    No message. System halts. (E)

           CAUSE      Interval timer is not causing a trap.  Second
                      possible cause of the error may be the instruction
                      unit.  Third possible cause of the error also may
                      be the translation look-aside buffer.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 12          MESSAGE    No message. System halts. (E)

           CAUSE      Recovery counter is not causing a trap.  Second
                      possible cause of the error may be the instruction
                      unit.  Third possible cause of the error also may
                      be the translation look-aside buffer.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 15          MESSAGE    No message. System halts. (E)

           CAUSE      Load to general register 0 modifies that register.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 16          MESSAGE    No message. System halts. (E)

           CAUSE      Nullified instruction stored to register file

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 17          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      word and modification (LDWM) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 18          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      word indexed and modification (LDWX,M) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 19          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      byte indexed and modification (LDBX,U,M) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 1A          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      half word indexed and modification (LDHX,U,M)
                      fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 1B          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      halfword indexed and modification (LDWX,U,M) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 20          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the operation of the register file
                      interlock fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 21          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      word and modification after (LDW,MA) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 22          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation for load
                      word and modification before (LDW,MB) fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 23          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the move to control register
                      (MTCTL) after load word (LDW) operation fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2A          MESSAGE    No message. System halts. (E)

           CAUSE      Nullified instruction after data trap stored to
                      register file.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2B          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the address calculation of the load
                      and modification that caused the data trap fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2C          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the ripple through recovery counter
                      fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2D          MESSAGE    No message. System halts. (E)

           CAUSE      Cannot force overflow trap.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2E          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the backup on recovery counter
                      fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 2F          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the late nullify on recovery
                      counter fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 31          MESSAGE    No message. System halts. (E)

           CAUSE      Unexpected recovery counter trap occurs.  Second
                      possible cause of the error may be the instruction
                      unit.  Third possible cause of the error also may
                      be the translation look-aside buffer.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 32          MESSAGE    No message. System halts. (E)

           CAUSE      Unexpected external interrupt trap occurs.  Second
                      possible cause of the error may be the instruction
                      unit.  Third possible cause of the error also may
                      be the translation look-aside buffer.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 40          MESSAGE    No message. System halts. (E)

           CAUSE      Test of the external interrupt request register
                      with zero fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 41          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the value of general register 1
                      after ADDIL instruction fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 42          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the calculation of the return
                      address with branch and link instruction fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 43          MESSAGE    No message. System halts. (E)

           CAUSE      Register file does not zero unused portion of the
                      target register for LDH instruction.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 44          MESSAGE    No message. System halts. (E)

           CAUSE      Register file does not zero unused portion of the
                      target register for LDB instruction.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 45          MESSAGE    No message. System halts. (E)

           CAUSE      Cannot distinguish between banks of the general
                      registers.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 46          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter operation
                      fails.  Counter cannot count up.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 47          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter operation with
                      nullify instruction fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 48          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter operation with
                      late nullify instruction fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 49          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter operation with
                      late nullify instruction caused by data trap fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4A          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter trap fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4B          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the recovery counter trap operation
                      immediately after data trap fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4C          MESSAGE    No message. System halts. (E)

           CAUSE      Cannot verify external interrupt enable mask.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4D          MESSAGE    No message. System halts. (E)

           CAUSE      Cannot verify external interrupt request register.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4E          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the external interrupt operation
                      fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 4F          MESSAGE    No message. System halts. (E)

           CAUSE      Cannot verify current privilege level after
                      execution of the gateway instruction.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 50          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the timing on board fails.

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------

 51          MESSAGE    No message. System halts. (E)

           CAUSE      Verification of the external interrupt request
                      register with high-priority machine check fails.
                      (EIRR bit gets set with HPMC.)

           ACTION     Contact your Hewlett-Packard Support
                      Representative.

---------------------------------------------------------------